Page 81
often for your productions. The second new event is a Scene Event (A, B, C or D), and it should immediately follow the MX-1 or MIXER event. The new event should be from a different play VCR than scene 002. The EDL should look similar to one of the EDLs below.
2. Use the up arrow to move to the first event in the EDL. 3. If the Record VCR uses IR control, put the VCR into Record Pause. 4. Press [SHIFT]+[AUTO-REC] to record the scenes. 5. After the scenes are recorded, press [R] to select the record VCR. (If the Record VCR uses IR, you will have to control that VCR manually.) 6. Check the resulting video on the Record VCR for the midpoint of the transition from A to B. If the "B" scene started early, the IN OFFSET for the B-Roll VCR is too large; if it started late, the offset is too small. (Note: The "B" VCR in this case is the second source in the A/B Roll and not necessarily the VCR attached to the "B" port.) 7. Use the same approach as you used for the Play VCRs OUT OFFSET to determine the amount of error and the amount of change to the current offset value. Change the IN OFFSET value. 8. Repeat steps 2 through 7 to verify your changes. Downloaded from www.Manualslib.com manuals search engine
Page 82
9. Repeat the above procedure for each play VCR that may be the "B" source in an A/B Roll. Accessing and Changing Offset Parameters: 1. Press [SETUP] to display Setup Menu 1.
2. Move the cursor to CONFIG and press [OK] to display the Configuration Menu.
3. Move the cursor to the VCR port (VCRA, VCRB, ... ,VCRR) whose offsets you are ready to adjust and press [OK]. The first parameter screen for that port displays.
4. Press the down arrow key three or four times until the IN/OUT OFFSET screen is displayed.
5. To change an offset value– • Move the cursor to the ± Sign field if that value needs to change and press [CHG]. • Move the cursor to the Offset Amount field if that value needs to change, press [CHG] to activate the numeric keys, then enter the new value for the offset. • Press [SETUP] to save your changes and return to the Configuration Menu. Press [SETUP] two more times to return to the EDL.
Downloaded from www.Manualslib.com manuals search engine
Page 83
Importing and Exporting If you have access to a personal computer (PC) and a communications software program, you can use Edit Suite's IMPORT, EXPORT, and CMX functions to - • export the EDL and Configuration Parameters to a PC • import a previously exported EDL and parameters to Edit Suite • export the EDL, in CMX format, to a PC. The EXPORT and IMPORT functions are for storage purposes only. You cannot view the file in a readable format or edit the EDL data. The CMX export displays in a readable format, but the format is different from the EDL format. Although this output was designed to make the EDL available to an on-line suite (PC-based editing), it is used most often to view the EDL information. Cable To connect Edit Suite to a PC, you need a serial communications cable. These cables are available at most computer supply stores. For a Macintosh, the cable is an 8-pin DIN to DB-9. A Videonics 232/422 cable (CBLA-0042-01) may be used. For most other computers, the cable is a DB-9 to DB-9 or DB-25 to DB-9 serial communications cable. Before connecting the cable, remove power from the computer and Edit Suite.
Macintosh Modem Port (8-pin DIN) to Edit Suite's Computer (RS-232C) DB-9 Port
PC Serial Comm Port (DB-9 or DB-25) to Edit Suite's Computer (RS-232C) DB-9 Port
Downloaded from www.Manualslib.com manuals search engine
Page 84
Communication Programs and Settings Edit Suite can communicate with most communication software programs that support XOn/XOff Flow Control. The table on the following page identifies three communication programs we have tested with Edit Suite, and the settings for each. Adapt these settings to your software package.
Communication Programs and Settings Computer
Macintosh
PC DOS
PC Windows
Communications Program Communications Menu Method Driver
MicroPhone II
ProComm
Terminal
Microphone Std. Standard
Press Alt-P and select table 12.
19,200 8 None 1 XOn-XOff
19,200 8 None 1
Baud Rate Data Bits Parity Stop Bits Flow Control Parity Check Carrier Detect Text Transfer End Outgoing Lines with: Save Text As: Wait for Echo Flow Control ASCII Transfer
CR Teach Text None
Echo Local Expand Blank Lines Pace Characters Character Pacing Line Pacing Down Loading CR LF Up Loading CR LF Terminal Emulation Terminal Preferences Line Wrap Local Echo Sound CR->CR/LF Inbound Outbound Transfer/Send Menu Protocol ASCII/Text
19,200 8 None 1 XOn-XOff (blank) (blank)
Standard Press Alt-S, select menu 6. Yes Yes 0 23 11 None None None None DEC VT-100 or DEC VT-52 X X X (blank) (blank)
Ensure that all settings are correct before you begin communicating with Edit Suite. Test by running Edit Suite's Export function without saving the data that is sent. You should see 255 lines of 32 characters per line scroll down your PC display. If not, either some of the above values are not set properly or your modem/communications port is not configured for computer-to-computer communications. Consult your PC or communication manuals for more information.
Downloaded from www.Manualslib.com manuals search engine
Page 85
Export The Export function is used to save all EDL and Configuration Data to a file on a personal computer. The file cannot be edited at the PC, and it is not in a readable format. The file can be sent back to Edit Suite via the Import function. To do an export, complete the following steps. #
Step
1.
At the PC, start the communications program. At the PC, create a file to save the Edit Suite data.
2.
Macintosh MicroPhone II
PC DOS ProComm
Select Open New Capture File in the File Menu.
Press [Page Down] to display the Download Protocol menu. Select Protocol 7 (ASCII).
Select a directory and file name. Click SAVE. 3.
PC Windows Terminal
Select Receive Text File... in the Transfers Menu. Select a directory and file name. Click OK.
Assign a file name and press return.
At Edit Suite: a. Press [SETUP] to display Setup Menu 1 and move the cursor to Export.
LCD CONFIG NEWVCR IMPORT EXPORT CMX
[OK]=BEGIN EXPORT b. Press [OK] to display the Export screen.
4.
c. Press [OK] to start the export, or, press [SETUP] to cancel the export. After the Edit Suite counter stops counting and the Setup Menu redisplays, at the PC, stop the file capture.
[OK]=BEGIN EXPORT 24_
While the export is in progress, line numbers between 00 and FF sequence on the display.
Select Turn Capture (No action Off in the File required.) Menu.
Downloaded from www.Manualslib.com manuals search engine
Select Stop in the Transfers Menu.
Page 86
Import The import function is used to restore a previously exported Edit Suite file. IMPORTANT: If an import is done, all EDL and configuration data currently stored in Edit Suite will be replaced by the imported data. All work-in-progress will be lost. Before attempting an import, ensure that all communication settings are correct. If the connections are not correct and the import fails, Edit Suite displays an NVRAM INIT message indicating that all EDL and configuration data has been deleted and the unit has been reset to factory conditions. To do an import, complete the following steps. #
Step
1.
At the PC, start the communications program. At the PC, locate and select the previously exported EDL file that you want to send to Edit Suite
2.
3.
Macintosh MicroPhone II
PC DOS ProComm
In the Transfer menu, select Send ... , and set the Protocol to ASCII/Text.
Press [Page Up] to display the Upload Protocol menu. Select Protocol 7 (ASCII).
Locate and select ... BUT DO NOT START SENDING THE FILE YET. the file to be sent, but do not click [SEND] .
Type the filename to be sent, but do not press Return.
At Edit Suite: a. Press [SETUP] to display Setup Menu 1 and move the cursor to Import.
PC Windows Terminal Select SendText File... in the Transfers Menu. Locate and select the file to be sent, but do not click [OK].
LCD CONFIG NEWVCR IMPORT EXPORT CMX
[OK]=SET IMPORT b. Press [OK] to display the Import screen. c. Press [OK] to prepare Edit Suite for the import and to start a 10-second time-out counter., or, press [SETUP] to cancel the import.
4.
At the PC, and within 10 seconds of completing Step 3, start sending the file.
[OK]=SET IMPORT A8_
While the 10-second time out is in progress, the wait indicator displays. If Step 4 is done before the 10 seconds elapse, line numbers between 00 and FE sequence on the display, after which Setup Menu 2 displays. If 10 seconds elapse before Step 4 is done, the Import is terminated and Setup Menu 2 redisplays.
Click [SEND].
Downloaded from www.Manualslib.com manuals search engine
Press [Return].
Click [OK].
Page 87
CMX The CMX function exports the EDL data, in CMX format, to a PC. This function is used most often to view the entire EDL in a single listing. Before using the CMX function, ensure that - • if there are MX1 Events in the EDL, the GPI-M configuration parameter is set to MX-1; or if there are MIXER Events, the GPI-M configuration parameter is set to MIXER • if there are INS or SPLT events in the EDL, the INS and SPLT parameters for VCRR are set to 1. If these settings are not correct, an error message will display during the export, or the event will be excluded from the CMX report. To do a CMX Export, complete the following steps. #
Step
1.
At the PC, start the communications program. Do this step if you want to save the CMX data to a file.
2.
If you just want to view the CMX listing, omit this step.
Macintosh MicroPhone II
PC DOS ProComm
Select Open New Capture File in the File Menu.
Press [Page Down] to display the Download Protocol menu. Select Protocol 7 (ASCII).
Select a directory and file name. Click SAVE.
3.
Select Receive Text File... in the Transfers Menu. Select a directory and file name. Click OK.
Assign a file name and press return.
At Edit Suite: a. Press [SETUP] to display Setup Menu 1 and move the cursor to CMX. b. Press [OK] to display the CMX screen.
4.
PC Windows Terminal
LCD CONFIG NEWVCR IMPORT EXPORT CMX
[OK]=BEGIN CMX EXPORT c. Press [OK] to start the CMX EXPORT CMX export IN PROGRESS, or, press [SETUP] to cancel the export. If you saved the data to a Select Turn Capture (No action Select Stop in the Transfers Menu. file, stop the file capture. Off in the File required.) Menu.
Downloaded from www.Manualslib.com manuals search engine
Page 88
The following is a sample CMX listing. CMX EVENT# VCR (001=A, 002=B, 003=C, 004=D) or Color (BL=Black, AX=Other Color) Insert Type (AA=Audio, V=Video) Transition Type (C=Cut, D=Dissolve, Wnnn=Wipe+Wipe#) Transition Duration (Frames: Max=255)
TITLE: EDIT SUITE EXPORT OF CMX 3400A EDL FCM: NON DROP FRAME 001 BL C 00:00:00:00 00:00:10:00 01:00:00:00 01:00:10:00 002 001 C 00:05:00:00 00:05:15:00 01:00:10:00 01:00:25:00 003 002 C 00:03:10:00 00:03:25:00 01:00:25:00 01:00:40:00 004 001 C 00:05:00:00 00:05:15:00 01:00:40:00 01:00:55:00 004 002 W001 255 00:03:10:00 00:03:25:00 01:00:55:00 01:01:10:00 005 001 C 00:05:00:00 00:05:15:00 01:01:10:00 01:01:25:00 006 001 C 00:06:00:00 00:06:15:00 01:01:25:00 01:01:40:00 007 002 C 00:03:30:00 00:04:00:00 01:01:40:00 01:02:10:00 GPI GPI-T PULSE 001 RI +00:00:15:00 008 002 AA/V C 00:21:20:00 00:21:40:00 01:15:00:00 01:15:20:00 EDIT SUITE STOP TILE GPI (always Relative In)
CMX Notes: 1. The CMX event numbers are sequential beginning with 001 - regardless of the EDL event numbers. 2. Sources are shown as 001 - 004 in CMX and A - D in Edit Suite. 3. An A/B Roll is shown as two lines in the CMX report, and both lines use the same event number (whereas Edit Suite uses two numbers). 4. There are three types of transitions in the CMX output: Dissolves, Cuts, and Wipes. Wipes are followed by a three-digit number. This is not the MX-1 transition number. 5. If an AXA Roll is in the EDL, the transition is ignored in CMX. 6. If an A/B/A or A/B/C Roll is in the EDL, the "B" scene will be divided into two events in the CMX export. 7. All GPI events are converted to Relative In for the CMX export. 8. If a Source event is the "A" source in an A/B Roll, its duration will display as 0. 9. Edit Suite does not store record deck times (except for insert events). For the CMX report, the record times begin at 01:00:00:00 and show the running time for the production.
Downloaded from www.Manualslib.com manuals search engine
Page 89
The EDL: The following are the EDL events that generated the CMX output on the preceding page. 001 SRC
DUR 00:00:10.00 COL=0
002 A
IN 00:05:00.00 OUT 00:05:15.00
003 B
IN 00:03:10.00 OUT 00:03:25.00
004 A
IN 00:05:00.00 OUT 00:05:15.00
004/005 FX=025 DI=> MX1 SP=3 BG=0 BC=5 005 B
IN 00:03:10.00 OUT 00:03:25.00
006 A
IN 00:05:00.00 OUT 00:05:15.00
007 A
IN 00:06:00.00 OUT 00:06:15.00
008 B
IN 00:03:30.00 OUT 00:04:00.00
008 GPI-T 009 B
FIXED 00:03:45.00
IN 00:21:20.00 OUT 00:21:40.00
009 IN 01:15:00.00 INSA OUT 01:15:20.00 V
STOP
Downloaded from www.Manualslib.com manuals search engine
TOTAL RT 00:02:30.00
Page 90
Chapter 9 • Setup and Configuration Menus
This chapter describes the choices in the Setup and Configuration Menus.
Setup Menus The Setup Menus access functions that are used to– • change the LCD viewing angle • turn on or off the beeper, error message text and the demo • import and export the EDL to a personal computer • add new VCR table definitions provided by Videonics. The Setup Menus are also used to access the Configuration Menu. This menu is used to configure Edit Suite's VCR and GPI ports so they can be used with your VCRs, camcorders, mixer and titler. To display Setup Menu 1, press [SETUP].
Setup Menu 1 Setup Menu 2 To move between Setup Menu 1 and 2, press the [up/down arrow] keys. To exit the Setup menus, with either Setup Menu 1 or 2 displayed, press [SETUP]. You are returned to the EDL event you were viewing before [SETUP] was pressed. If there are no events in the EDL, the NEW Menu displays. See Chapter 5 for a description of the NEW Menu. To exit Setup from the Configuration Menu, press [SETUP] to return to Setup Menu 1, then press [SETUP] again to return to the EDL. To select a Setup function or to display the Configuration Menu, use the [left/right arrow] keys to Downloaded from www.Manualslib.com manuals search engine