Page 101
GPI-M and GPI-T Configuration Parameters The GPI-M choice in the Configuration Menu is used to specify the type of GPI (general purpose interface) device that will be attached to Edit Suite's GPI-M port–a Videonics MX-1, a third-party mixer or switcher, or another type of GPI-device. For the latter choices, it is also used to specify the offset
Downloaded from www.Manualslib.com manuals search engine
Page 102
amount to use so that Edit Suite sends the GPI trigger at the correct time. The GPI-T choice is used only for specifying the offset value for the trigger pulses. See GPI Events in Chapter 5 for more information. The MX-1 and third-party mixers/switchers cannot be used with the GPI-T port. To display the Configuration Menu, from Setup Menu 1, move the cursor to CONFIG and press [OK]. To return to Setup Menu 1 from the Configuration Menu, press [SETUP].
Setup Menu 1 Configuration Menu
To access the GPI-M or GPI-T parameters, move the cursor to GPI-M or GPI-T in the Configuration Menu and press [OK]. GPI-M Choices GPI-T
The GPI-M Choices above show each of the choices for the GPI-M port. To cycle between the choices, with the cursor in the GPI-M field, press [CHG]. Select MX-1 if a Videonics MX-1 is attached to the GPI-M port; select MIXER if a third-party mixer or switcher is attached; select GPI if a GPI-device other than a mixer or switcher is used, or if no device is attached to the port. To change the sign (+ or -) for either of the GPI-M or GPI-T offset values, move the cursor to the sign field and press [CHG]. To change the Offset values for GPI-M or GPI-T, move the cursor to the offset value field, press [CHG] to activate the numeric keys, enter the offset amount (or turn the jog/shuttle to change the current value), Downloaded from www.Manualslib.com manuals search engine
Page 103
and press [OK]. See MIXER Events or GPI Events in Chapter 5 to determine the amount of offset. To return to the Configuration Menu from either GPI parameter screen, press [SETUP].
Downloaded from www.Manualslib.com manuals search engine
Page 104
Chapter 10 • Error Messages and Troubleshooting This chapter provides two tables to help you solve problems that may occur while using Edit Suite. These are the Error Messages Table and the Troubleshooting Table. The Error Messages Table lists each Error Message that displays in Edit Suite, describes the cause of the error, and provides actions for you to take to fix the error or prevent it from occurring again. The Troubleshooting Table lists problem symptoms that you may encounter, and provides the actions to take to isolate, prevent, or work around the cause of the problem.
Error Messages If Edit Suite detects an error or advisory condition, it displays an error message similar to the following.
To clear an error message, press [OK]. To redisplay the most recent error message, press [SHIFT]+[OK]. Error Message Table #
Message, Meaning, and Action
01 Out pt before in pt During a preview or auto-record, a scene event whose OUT time is the same as or earlier than its IN time was detected. Change the scene's IN and/or OUT time and rerun the preview or auto-record. To locate the scene on the videotape, display the event in the LCD, then press [GO TO]+[IN] or [GO TO]+[OUT].
Downloaded from www.Manualslib.com manuals search engine
Page 105
05 No response from VCR Edit Suite attempted to communicate with a VCR but did not receive or could not recognize the response from the VCR. Verify that the control cable between Edit Suite and the VCR is connected, that a videotape is loaded, and that the VCR is turned on. If the VCR has a Master/Slave switch, select Slave. If it has a Local/ Remote switch, select Remote. Of special note are VCRs like the Sony EV-S7000 and EV-S9000P. Both of these VCRs have a menu selection for Master/Slave that defaults to Master whenever power is removed from then reapplied to the VCR. Make sure you reselect Slave. Verify that the correct protocol is selected in CONFIG/VCR_/ PROTO. If the VCR uses RS-232 or RS-422 protocol, press [SHIFT] +[STOP] to reinitialize communication with the VCR. 06 Split delay out of range The amount of delay in a SPLT event is greater than or equal to the length of the insert. Decrease the amount of delay in the SPLT event. 09 Tape address not found Edit Suite searched for a time code or counter address but was unable to locate the address. The scene Edit Suite is looking for may be too close to the start of the tape. Scenes should not start earlier than approximately one minute from the start of a fully rewound tape. Reattempt the preview, auto-record or GO TO. If the error occurs again, verify that the correct videotape is loaded. If time code is not being used, rewind the tape, reset the counter, and try again. If RCTC is used, verify that the VCR/camcorder is set to send time code and that the tape is striped with RCTC.
Downloaded from www.Manualslib.com manuals search engine
Page 106
If the problem persists, increase the PLY (play) Advanced Parameter by five (5) seconds, but be sure that the REW (rewind) parameter value is equal to or greater than PLY and that both are less than the FFD (fast forward) parameter. Error 9 also displays if a search is in progress but is terminated early by pressing a Transport key or turning the Jog/Shuttle. 10 VCR number not available During VCR Configuration, a VCR number that is not defined in Edit Suite was entered. The VCR table number will be changed automatically to table 001. If table 001 is not the table you want to use, return to the VCR field and enter one of the table numbers from Appendix A. 11 VCR table corrupt The selected VCR table number is not usable, Edit Suite's memory has become corrupt, or there is a problem with the LCD. Unplug then reconnect power to Edit Suite to reset its memory. If the error persists, retype the VCR number for each VCR. If this does not fix the problem, select a different VCR table number from Appendix A. If there are garbage characters on the LCD, the LCD connection may be loose. If this occurs, unplug then reconnect power to Edit Suite. If the display still shows garbage, contact your dealer or Videonics to have the unit repaired. 12 EDL full An attempt to create or copy an event was done, but there are not enough empty events in the EDL to complete the create/copy. The maximum number of events in the EDL is 250. If you need more than 250 events and have access to a computer, use the Setup/Export function to save the EDL on a computer, then delete the existing EDL via the Setup/EDL function. If you do not have access to a computer, you will have to delete some events before new events can be created.
Downloaded from www.Manualslib.com manuals search engine
Page 107
13 EDL empty The last remaining event in the EDL was deleted. This is an advisory message only. After pressing [OK] to clear the message, the NEW menu displays. 14 EDL corrupt After a [CUT] or a [SHIFT]+[CUT], the EDL was found to be unusable. The entire EDL will need to be deleted. Use the Setup/EDL function to delete it. If you have a copy of the EDL stored on a PC, use the Setup/Import function to restore the EDL. 15 VCR table too large An attempt to add a VCR table using the NEWVCR function was made, but there is not enough memory left in Edit Suite to add the table. Any single table you have been provided is small enough to fit in memory; however, if you have added other tables via the NEWVCR function, the combination may exceed memory limits. The only way to make room for the new table is to delete the existing tables. To do this, you must fully reset your unit which will delete all EDL and configuration data. If you need to do this, unplug Edit Suite, then press and hold [SHIFT]+ [ALL STOP] while reconnecting power to Edit Suite. 16 No valid group found [SHIFT]+[AUTO REC] was pressed, but there are no events in the EDL. Clear the message. The NEW menu displays. If you were attempting to do an assemble edit, press [REC] only instead of [SHIFT]+[AUTO REC].
Downloaded from www.Manualslib.com manuals search engine
Page 108
17 Invalid primary tile A Source (SRC) Event with no duration was encountered during a preview or auto-record. Enter a duration for the Source Event. 18 No VITC found Edit Suite attempted to read VITC time code but was unable to do so. If the TCSRC parameter is set to INT (internal), ensure that the VCR/ camcorder is set to send VITC instead of LTC, RCTC or counter. If the TCSRC parameter is set to EXT, ensure that a video cable is attached from the VCR's video out to the correct Time Code In port on Edit Suite. Ensure that there is VITC on your tape. If your VCR can show VITC on its counter, use that to do your verification. If you have a monitor with a vertical hold, you can adjust the hold to see the VITC (a series of short vertical lines) at the top of the video. If the TCSRC parameter is set to EXT, check the STABLE Advanced parameter. If it is not set to 45, change it to 45. If it is already 45, increase its value to 60 and try again. If you increase STABLE, also increase the PLY (play) parameter by two (2) seconds and the REW (rewind) parameter by four (4) seconds. 19 No LTC found Edit Suite attempted to read LTC time code but was unable to do so, or TCSRC=EXT and TC=NONE or RCTC. If TC=NONE or RCTC, the TCSRC parameter must be set to INT (internal). If TC=LTC and TCSRC=INT (internal), ensure that the VCR/ camcorder is set to send LTC instead of VITC, RCTC or the Real Time Counter. If TC=LTC and TCSRC=EXT, ensure that an audio cable is attached Downloaded from www.Manualslib.com manuals search engine
Page 109
from the VCR's Time Code Out or Audio OUT channel that contains the LTC to the correct Time Code IN port on Edit Suite. Ensure that there is LTC on your tape. If your VCR can show LTC on its counter, use that to do your verification. Otherwise, connect the LTC cable directly to the audio IN on your monitor and listen for the LTC. It will sound like a high-pitched squeal. If the TCSRC parameter is set to EXT, check the STABLE Advanced parameter. If it is not set to 45, change it to 45. If it is already 45, increase its value to 60 and try again. If you increase STABLE, also increase the PLY (play) parameter by two (2) seconds and the REW (rewind) parameter by four (4) seconds. 20 VCR not specified During a preview or an auto-record, either an event referenced a VCR port that has a PROTO set to NONE, or VCRR's PROTO is set to NONE. In the SETUP/CONFIG menu, check the PROTO setting for each VCR attached to Edit Suite. If the settings are correct, ensure that none of the events reference a VCR (A/B/C/D) that is not defined in CONFIG. 21 No MX-1 found Edit Suite attempted to communicate with a Videonics MX-1 but was unable to do so. This usually occurs during a preview or auto-record, or when the GPI-M key is pressed. 1. Make sure your GPI cable is a stereo cable. 2. If you are not using an MX-1, change the CONFIG/GPI-M setting from MX-1 to either MIXER (if a third-party mixer/switcher is used) or to GPI (if a GPI device is used, or if no mixer/switcher or MX-1 is used). 3. If you have an MX-1, verify that the GPI cable is connected to Edit Suite's GPI-M port and to the MX-1's GPI port. Ensure that the MX-1 is turned on. If it is, cycle its power.
Downloaded from www.Manualslib.com manuals search engine
Page 110
22 Invalid ED# The EDL number entered in the GO TO function ([GO TO]+[OK]) does not exist in the EDL. If you know the EDL number, try the GO TO function again. Otherwise, use the up/down arrow keys to search through the EDL for the event. 23 Insert not available An INS (insert) event is specified, but the VCRR configuration indicates that the record VCR cannot do inserts. If the record VCR can do inserts, change the INS parameter in SETUP/CONFIG/VCRR from 0 to 1. If the record VCR cannot do inserts, delete the INS Events from the EDL. 24 Split not available A SPLT (split insert) event is specified, but the VCRR configuration indicates that the record VCR cannot do split inserts. If the record VCR can do split inserts, change the SPLT parameter in SETUP/CONFIG/VCRR from 0 to 1. Also ensure that the INS (insert) parameter is set to 1. If the record VCR cannot do split inserts, delete the SPLT Events from the EDL.
Error Message Display Format A Setup parameter–MSGS–determines whether error messages will display message numbers only or message numbers and message text. The following are example of both choices.
Message Number Only Message Number and Text