Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 6

VN-855 and VN-855-C, VN-855DN and VN-855DN-C, VN-855WDR and VN-855WDR-C IP Cameras (ViconNet Ver 3), pages 14 to 22

Pages 14 to 22 of 37

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Vicon VN-855

Page 14

8 3. Open the iris completely. If an autoiris lens used, reduce the room lighting to allow the lens to open completely. This gives the most accurate results. 4. Zoom the lens in to the maximum telephoto setting. Adjust the optical focus of the lens using the remote lens control. 5. Zoom out to the maximum wide angle setting. If the picture is no longer in focus, readjust the backfocus screw. 6. Repeat steps 4~6 until the image remains sharp through the entire zoom range. This completes the adjustment. The backfocus adjustment screw is held in place by friction, so there is no locking screw.

13. CAMERA MOUNTING HOLE There are two mounting holes provided, one each on the top and bottom of the camera.

OSD MENU SET UP FOR VN-855WDRV3 CAMERA Settings for the VN-855WDRV3 camera can also be done from an OSD menu system after the camera is setup in the ViconNet system (ViconNet setup procedure follows). Refer to the most current ViconNet manual, XX113-0X, for detailed instructions on using ViconNet. Configuration of the VN-855WDR is done by activating the PTZ driver as SurveyorVFT default configuration (4800 bps). Be sure the most current PTZ driver is installed. After configuration is completed, the driver MUST BE DISABLED to prevent confusion about PTZ functions of this fixed camera during operation. Enter Preset 94 to enter the menu system. Use AP to make submenu selections, AI to escape submenus, Pan Left/Right to make changes/selections and Tilt Up/Down to move the cursor in the menu system and navigate between menus. When using the mouse to set parameters that have a large range of settings, clicking and holding the mouse will scroll quickly through the numbers.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 15

9

Menu Flow Chart

LENS

MANUAL ELC level setting

(MANUAL/DC)

WDR

BLC

BLC level and zone setting

(OFF/BLC/WDR)

WDR

DAY/NIGHT

COLOR

WDR level setting

SHUTTER SPEED, AGC, FLICKERLESS setting

(COLOR/BW)

BW SHUTTER SPEED, AGC, FLICKERLESS setting

AWB

MANUAL MANUAL RED, BLUE value setting

(ATW1/ATW2/AWC/MANUAL)

SPECIAL

BLEMISH, PRIORITY, POSI/NEGA, SHARPNESS

EXIT (QUIT/SAVE/PRESET)

Main Menu

LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 ATW1 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

Caution: In order to change setting values in the menus, first set PRIORITY to REMOTE on SPECIAL menu. The SPECIAL menu must be set to REMOTE before menu items are set for them to take effect.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 16

10

LENS -

Select according to lens type: Manual Iris Lens: Manual mode DC Drive Lens: DC mode

-

When WDR function is set to ON, mode changes to DC mode, and DC Iris level cannot be setup.

DC Drive Lens -

In Lens menu, select DC using Tilt Up/Down and press AP key. When in DC mode, settings are done using to Level control potentiometer on the camera.

Manual Iris Lens -

In Lens Menu, select MANUAL using Tilt Up/Down and press AP key.

-

In the following screen, adjust the brightness level using Pan Left/Right. (ELC) LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 ATW1 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

LEVEL

80

WDR (Wide Dynamic Range) WDR -

Using this function, both the indoor and outdoor scenes display clearly.

-

Select WDR using Tilt Up/Down and press AP key. Select the Level with Pan Left/Right. (WDR) LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 WDR COLOR4 ATW1 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

LEVEL

74

BLC (Backlight Compensation) -

In general, Iris is adjusted for a bright area, so the face of a person who stands against a bright area appears dark.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 17

11 -

With BLC function, the face displays clearly.

-

In the WDR Menu: Select BLC and press AP key. In the screen that follows, select “Level” and “Area” (Right, Left, Top, Bottom). (WDR) LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 BLC COLOR4 ATW1 4 QUIT

LEVEL AREA

Use ▲ ▼ ◀ ▶ , AP to select

3 RIGHT

The WDR function can be set to OFF.

Day/Night Color -

In this mode, video output is always color, regardless of illumination.

-

In Day/Night Menu: Select Color and press AP key. In the following screen, select Shutter (speed), AGC (Level) and Flickerless (ON/OFF). Shutter and Flickerless settings are available in Lens DC mode only. Otherwise the display as N.A.

When Manual mode is selected in Lens Menu, set up of Shutter and Flickerless is not available. (COLOR) LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 ATW1 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

SHUTTER AGC FLICKERLESS

N.A. HIGH N.A.

-

Shutter mode: Supports 9 levels between 1/100 sec ~ 1/50,000 sec.

-

AGC mode: Automatic Gain can be setup as High/Low/Off using Pan Left/Right. In a dark environment, when AGC gain is set to high, the image becomes brighter.

-

Flickerless mode: When ON, shutter speed is fixed at 1/100 sec.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 18

12 Black-and-White (BW) -

In this mode, video output is black-and-white (without IR filter), regardless of illumination.

-

This function is useful in a dark environment and is the same as using a black-and-white camera.

-

Day/Night Menu: Select BW and enter Preset 94. In the screen that follows, select Shutter (speed), AGC (Level), and Flickerless (ON/OFF).

(BW) LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF BW4 ATW1 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

SHUTTER AGC FLICKERLESS

OFF HIGH OFF

AWB -

White Balance function can be setup according to environment.

-

In AWB menu, 4 levels (ATW1, ATW2, AWC, Manual) can be setup.

ATW 1 -

White Balance is automatically adjusted in the range of 2500K~7500K degrees.

ATW 2 -

White Balance is automatically adjusted regardless of the range of color temperature.

LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 ATW1 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 ATW2 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 19

13

AWC -

This function is used to set the best color temperature in the current environment. If camera has full white screen in front of white paper, and AP key is pressed, the camera is fixed at the best color temperature. “Wait” displays while it sets.

-

When the environment is changed, new settings are needed using the same method.

LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 AWC 4 QUIT

LENS WDR DAY/NIGHT AWB SPECIAL EXIT

Use ▲ ▼ ◀ ▶ , AP to select

MANUAL4 OFF COLOR4 WAIT 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

Manual -

White Balance can be directly adjusted by user.

-

In Manual mode, press AP key to get following screen.

(MANUAL AWB) LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 MANUAL 4 QUIT

Use ▲ ▼ ◀ ▶ , AP to select

-

R GAIN B GAIN

68 64

In R Gain and B Gain modes, the value of Red and Blue can be controlled using the keypad. Considering the change of color, select proper values and fix color temperature. Caution: Auto White Balance function can work incorrectly in high temperature (bright sky, sunset), darkness, or drastic change of light.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 20

14

SPECIAL -

In Special menu, if AP key is pressed, Blemish, Priority, Posi/Nega, and Sharpness can be adjusted.

LENS WDR DAY/NIGHT AWB SPECIAL EXIT

(SPECIAL)

MANUAL4 BLC COLOR4 AWC 4 QUIT

BLEMISH PRIORITY POSI/NEGA SHARPNESS

OFF DIP SW + 96

Use AI to exit

Use ▲ ▼ ◀ ▶ , AP to select

Blemish Blemish Mode is selectable between ON and OFF using Pan Left/Right. When BLEMISH is “ON”, it compensates for pixels with uneven light levels (white spots). Caution: Before selection of Blemish ON, lens must be covered so the sunlight is blocked to the CCD. Priority Set Priority using Pan Left/Right on Priority Mode. Set to Remote to use the OSD menu system. (This must be set before making any other menu selections for the settings to take effect.) When setting to DIP SW, menu setting values will not be applied. Use the DIP switch on the rear of the camera for settings. POSI/NEGA In Posi/Nega mode, brightness of video shows (+: normal, -: reverses to negative image). Sharpness In Sharpness mode, outline of video image can be controlled. At high level, outline is clear; however, when level is too high, noise can occur.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 21

15

EXIT -

Exit Menu is used to close the menu.

-

The menu is setup with 3 choices (Quit, Save, Preset).

LENS WDR DAY/NIGHT AWB SPECIAL EXIT

MANUAL4 OFF COLOR4 ATW1 4 QUIT

Use the AP key to exit the OSD system.

QUIT -

Changes are not saved. Previously saved menu remains and the menu is closed

SAVE -

Changes are saved and menu is closed.

PRESET -

All of setup menu goes to factory default and menu is closed.

VICONNET CONFIGURATION Network Considerations The VN-855IP IP Camera can be connected to any ViconNet network (Version 3 software). Kollector Elite Recorders and ViconNet Workstations can be used for live viewing and recording of network-streamed video. A network can be as simple as a single VN-855IP camera connected to a ViconNet Workstation or can be complex with the addition of several networks interconnected via WAN.

When adding a VN-855IP IP Camera to the ViconNet network, the following items must be considered: •

The number of cameras on a switch with respect to switch capabilities and system bandwidth mapping.

•

Bandwidth limitations on ports connected to workstations (using 100 or 1000 Mbps).

•

Workstation capabilities such as processing speed, disk write speed and display card strength.

•

Storage size and location types including local Workstation recording, attached SCSI RAID and integrated NAS/SAN devices.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 22

16

Configuring ViconNet (IP/LAN) The VN-855IP camera is shipped with a ViconNet version 3 CD that contains the ViconNet version 3 software needed to setup your IP system, including the application setup, the camera firmware and setup software (VNSetup). Be sure the ViconNet Workstation meets the minimum requirements, is running the ViconNet application (version 3) (VNSetup) and has the proper PTZ camera driver. The VNSetup is found on the included CD under software, IP Camera Setup. Refer to appropriate ViconNet documentation.

The default parameters on the IP camera are: IP address: [10.10.10.1]. Nucleus IP address: [1.1.1.1].

On first startup, the camera will attempt to establish connection to the Nucleus with the default address (1.1.1.1). Connecting it to an active Nucleus is done through the VNSetup utility.

Note: When connecting to ViconNet application version 3, the number of concurrent users viewing video from the same device cannot exceed 10 users. Groups and Users Restrictions ViconNet allows creating Multiple Groups and Users in order to limit the rights to different levels. For more information on how to create Users and Groups, refer to the latest revision of ViconNet manual XX113.

Although the ViconNet software does not limit the number of Groups and Users that can be created, the VN-855IP IP Camera has Users and Groups limitations. For ViconNet version 3, the camera can support the first 20 Groups (including Administrators and Guests) and the first 100 Users.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera