VN-855 and VN-855-C, VN-855DN and VN-855DN-C, VN-855WDR and VN-855WDR-C IP Cameras (ViconNet Ver 3), pages 5 to 13

Pages 5 to 13 of 37: Contents; Important Safeguards

The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Vicon VN-855

Page 5

i

Contents Important Safeguards ...................................................................................................................................... i Precautions ....................................................................................................................................................... 2 Connectors and Controls ............................................................................................................................... 3 OSD Menu for VN-855WDR............................................................................................................................. 8 ViconNet Configuration. ............................................................................................................................... 15 Shipping Instructions.................................................................................................................................... 24 Coaxial Cable Recommendations................................................................................................................ 25 Twisted-Pair Cable ........................................................................................................................................ 26 Network Cable................................................................................................................................................ 27 Technical Information ................................................................................................................................... 29 Vicon Standard Equipment Warranty.......................................................................................................... 30

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 6

This page is a scan with no text; see it in the PDF.

Page 7

i

Important Safeguards GRAPHIC SYMBOL EXPLANATION The lightening bolt symbol alerts the user to the presence of dangerous voltage that may present the risk of electric shock.

12. Power Cord Protection - Power supply cords should not be routed in trafficked areas or in tight spaces where they will be pinched or used to bear weight. Allow some slack in the cord where it enters the unit. 13. Outdoor Cable Grounding - Use only grounded outdoor cables to protect against voltage surges and static charges. Section 810 of the National Electrical Code, ANSI/NFPA 701984, provides information on proper grounding of the lead-in wire to an antenna discharge unit, size of grounding conductors and the requirements of grounding electrodes. 14. Lightning - Disconnect the product from its power source and cable system when possible to prevent damage due to lightning and power-line surges. 15. Power Lines - Do not locate outside cables over power or utility lines where they can fall and make direct contact. Contact with power lines can be fatal.

The exclamation point symbol alerts the user to the presence of important operating and maintenance instructions.

16. Overloading - Do not overload wall outlets and extension cords to prevent risk of fire and electric shock.

1. Read Instructions - Read all safety and operating instructions before the product is operated.

17. Object and Liquid Entry - Never probe through, or spill liquid into, enclosure openings to prevent risk of fire or electric shock.

2. Retain Instructions - Retain all safety and operating instructions for future reference. 3. Heed Warnings - Pay attention to all product warnings.

18. Servicing - Refer all servicing to qualified service personnel. 19. Damage Requiring Service - Obtain service when: The power-supply cord or plug is damaged.

4. Follow Instructions - Follow all operating instructions. 5. Cleaning - (Do not use caustic, abrasive or aerosol cleaners) For units that CAN BE DISCONNECTED from the power source, use a damp cloth for cleaning. For units that CANNOT BE DISCONNECTED from the power source, use a damp cloth for cleaning and do not allow moisture or liquids to enter vents. 6. Attachments - Use only Vicon recommended attachments to prevent unit damage and personal injury. 7. Water and Moisture - Use only products designed for outdoor environments where they will be exposed to water or moisture. 8. Accessories - Do not place the unit on an unstable surface to avoid falling. Use only Vicon recommended mounting accessories. 9. Ventilation - Do not block ventilating slots and openings as they ensure reliable operation. Do not place the unit near a heat source or into an enclosure unless recommended by Vicon. 10. Power Sources - The product should only be operated from the recommended power source. If not specified, consult your Vicon dealer or local power company. 11. Grounding - Only products equipped with a 3-prong grounded plug should be inserted into a grounded power outlet. Contact an electrician to replace an obsolete outlet. Do not force a plug into a non-grounded outlet.

Objects have fallen or liquid has been spilled into the product. The product is not designed for outdoor use and has been exposed to water or moisture. The product does not operate per the operating instructions. Perform Vicon recommended adjustments, modifications and troubleshooting only to avoid unit damage and personal injury. The product has been dropped. The product shows a significant change in performance. 20. Replacement Parts - Use only Vicon specified replacement parts or an approved equivalent to prevent unit damage and injury. 21. Safety Check - Request safety checks to be performed following repair or maintenance to verify proper operation. 22. ESD Precaution - Take all normal electrostatic discharge precautions to avoid component damage during installation and operation. 23. For 230 VAC Devices- When the disconnect device is not incorporated in the equipment or when the plug on the power supply is intended to serve as the disconnect device, follow the guidelines below: For permanently connected 230 VAC units, a readily accessible disconnect device must be incorporated into the site wiring. For 230 VAC units with a plug, the outlet must be installed near the unit and be easily accessible.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 8

2

PRECAUTIONS 1. Installation of the camera must be performed by qualified service personnel in accordance with all local and national electrical and mechanical codes. 2. Do not attempt to disassemble the camera. In order to prevent electric shock, do not remove screws or cover. There are no user-serviceable parts inside. 3. Handle the camera with care. The camera could be damaged by improper handling or storage. 4. Do not expose the camera to rain or moisture, or try to operate it in wet areas. Take immediate action if the camera becomes wet. Turn the power off and refer servicing to qualified service personnel. Moisture can damage the camera and also create a danger of electric shock. 5. Do not use strong or abrasive detergents when cleaning the camera body. Use a dry cloth to clean the camera when dirty. In a case where the dirt is hard to remove, use a mild detergent and wipe gently. 6. Never point the camera toward the sun. Whether the camera is used outdoors or not, never point it toward the sun. Use caution when operating the camera in the vicinity of spot lights or other bright lights and light reflecting objects. 7. Do not operate the camera beyond its temperature, humidity or power source ratings. Do not use the camera in an extreme environment where high temperature or high humidity exists. Use the camera under conditions where temperatures are between 14°F~122°F (-10°C~+50°C), and humidity is below 85%. For the correct power supply, refer to the specification sheet. 8. If using 24 VAC power adapter, only use the 24 VAC UL Listed Class 2 power transformer. 9. Only use a Listed Class 2 power source. Caution: To prevent fire or shock hazard, UL listed wire VW-1, style 1007 should be used for the cable.

PACKING LIST 1. Iris lens connector plug for DC drive – 1 pc 2. Dust protective cap – 1 pc 3. Ferrite clamp – 2 pc (WDR only) 4. Power connector – 1 pc 5. 6-pin alarm/mic connector – 1 pc

The I-Onyx™ VN-855 is an integrated camera that captures digital video as well as converts analog video to digital video and transmits the video over the ViconNet® network (using Version 3 software). The VN-855 delivers up to 30 fps.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 9

3

CONNECTORS AND CONTROLS [High-Resolution Model VN-855]

[Day/Night Model VN-855DN]

[WDR Model VN-855WDR]

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 10

4

1. ETHERNET (Network Port) Connects to Internet, Ethernet (10Base-T/100Base-T). There are 2 LEDs on the RJ-45 connector. The green LED indicates that there is connection to the Network. The amber LED indicates Network activity (data flowing to the camera). This connection also provides PoE (Power over Ethernet). When using PoE, a PoE device, such as the NETSWITCHPOE-24, is required.

2. STATUS This LED indicates that the camera IP board is live. If the camera is live, the blue LED blinks.

3. ALARM (Alarm Input) and AUDIO (Microphone) This terminal block input provides 1 alarm and 1 audio input to the camera. ALARM (Alarm Output) can be defined in the ViconNet application as a relay. It can be set as ON-High, OFF – Low or Momentary (momentarily ON). Note: To connect to a relay device, the electrical specifications are: open-drain output accepts voltages up to 5.5 V, 24 mA output drive at 3.3 V, non-inductive.

4. VIDEO OUT (CH1) 1.0 V p-p/75 ohm composite video signal is provided at this BNC connector.

5. MODE SELECT SWITCH – (This switch varies according to model) Note: The VN-855WDR can be set up through an OSD menu system; refer to the section that follows for programming the camera. The camera defaults to DIP switch settings. The PRIORITY setting in the SPECIAL menu must be set to REMOTE in order to set the OSD settings. 1. ELC/ALC Select Switch This switch is used to select ELC (electronic light control)/EE (electronic exposure) mode or ALC (automatic light control)/AI (autoiris lens) mode. Pole 4 is set to ON for EE/ELC and OFF for AI/ALC. In the EE/ELC mode, a continuously variable electronic shutter is employed to automatically control the exposure time of the CCD image sensor according to the incoming light level. With this

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 11

5 mode selected, a fixed or manual iris lens can be used instead of an autoiris lens. In the AI/ALC mode, the CCD shutter speed is fixed to 1/60 (NTSC, 1/50 PAL) sec, and the incoming light level is controlled by the autoiris lens. When using a DC-drive type of autoiris lens, set this switch to the AI/ALC position. Cautions: 1) Under bright lighting conditions such as a sunny day outdoors, use an autoiris lens; the EE/ELC control range is not wide enough under these conditions. 2) Under certain unique lighting conditions, the following phenomena may appear: Strong smear and/or blooming on high light objects such as spotlights or windows. Noticeable flicker in the picture and/or color rendition variations. To avoid this, use an autoiris lens. 3) When operating in EE/ELC mode with a manual iris lens, the depth of field of the image may be less than that obtained by using an AI/ALC lens. Depth of field varies inversely with the iris opening. Thus, using this camera in ELC mode with the manual iris lens fully opened may result in less depth of field and the distant objects in the picture may be seen out of focus. Note: When adjusting the focus, it is recommended that the iris be completely open (a dark condition, either at night or using a filter) so that the depth of field does not influence the adjustment. 4) Fixed iris or manual iris lenses may be used with the linear shutter (EE/ELC mode) when the scene brightness varies over a limited range. 5) Do not use the EE/ELC mode when an autoiris lens is installed. 2. FLK (flickerless) ON/OFF Switch This function is only used in Japan. When set to ON, the shutter speed is fixed at a rate of 1/100 (120) sec. 3. BLC (Backlight Compensation) ON/OFF Switch OR WDR (Wide Dynamic Range) ON/OFF Switch (VN-855WDR only) If the subject being viewed is too dim because of a bright background, set the BLC switch (Pole 3) to ON to compensate for the bright background. With BLC on, the background brightness may saturate in some cases. This function may not operate properly if the object is too small compared to the area of the background. This function can be used with either the linear shutter (EE/ELC mode) or an autoiris lens (AI lens/ALC mode). For the VN-855WDR, the Wide Dynamic Range (WDR) function, which provides the best contrast for high quality images, can be turned ON or OFF.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 12

6

WITH BLC/WDR OFF

WITH BLC ON

WITH WDR ON

4. AGC (Automatic gain Control) ON/OFF This switch is provided for the AGC circuit. The AGC circuit incorporated into the camera boosts the sensitivity automatically when the scene illumination is insufficient. 5. AGC MAX ON/OFF Switch OR DAY/NIGHT ON/OFF Switch (VN-855DN only) The automatic MORE-GAIN function automatically adjusts picture gain in accordance with the brightness of the subject. This function is enabled when set to ON. For the VN-855DN camera, the day/night function can be turned ON or OFF.

6. AUTOIRIS LENS CONNECTOR FOR DC DRIVE LENS This connector supplies the control signals to the DC drive autoiris lens.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 13

7 7. ALC LEVEL ADJUSTMENT POTENTIOMETER FOR DC DRIVE LENS This potentiometer is used only if the camera is fitted with a DC drive autoiris lens. It is used to control the amount of light striking the CCD image sensor.

LENS-IRIS level control

Monitor Screen

LEVEL Control Direction

To increase the brightness

Clockwise

To decrease the brightness

Counterclockwise

8. POWER IN (24 VAC) This terminal accepts 24 VAC power source. Recommended power supply is minimum 9 W (when not using PoE). Caution: To prevent fire or shock hazard, UL Listed wire VW-1, style 1007 should be used for the cable for 24 VAC input terminal.

9. POWER INDICATOR LED This LED turns ON only when power is supplied and the DC-DC converter (or the regulator) inside the camera works properly or PoE is functioning. 10. CCD DUST PROTECTIVE CAP Remove this cap before installing the lens. Do not handle or leave the camera with cap off. 12. BACKFOCUS ADJUSTMENT This is used to position the CCD image sensor at the precise point of focus the lens. Backfocusing Fixed-Focal-Length Lenses 1. Install a lens and connect the camera to a monitor and power supply. 2. Open the iris completely. If an autoiris lens used, reduce the room lighting to allow the lens to open completely. This gives the most accurate results. 3. Adjust the screw slowly until the sharpest picture is obtained. This completes the adjustment. The backfocus adjustment screw is held in place by friction, so there is no locking screw. Backfocusing Zoom Lenses 1. Install a lens and connect the camera to a monitor and power supply. If the lens is motorized, it must also be connected to a lens control. 2. Position the camera 25~50 feet (8~16 meters) from a flat vertical surface suitable for focusing. A newspaper works well as a focusing target.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera