For the Vernier LabPro

Page 10

Tutorial: Temperature Measurement with Logger Pro A good way to get acquainted with LabPro is by performing a simple experiment. Using this tutorial, you will take measurements using a temperature sensor. Follow the simple steps, and you are well on your way to collecting and analyzing data with a computer.

MATERIALS Computer LabPro interface Vernier Stainless Steel Temperature Probe One 250 mL beaker or cup 100 mL hot water

PROCEDURE 1. Place about 100 mL of hot water into a 250 mL beaker or a cup. 2. Connect the Stainless Steel Temperature Probe to CH 1 on LabPro, and place the temperature probe on the tabletop. 3. Start the Logger Pro software. Logger Pro will detect the auto-ID sensor, set the data collection parameters, and computer display. In this case, collection parameters are 1.0 sample per second and 180 samples. The program displays a graph and data table on the computer. The vertical axis of the graph will have temperature scaled from 0 to 50°C. The horizontal axis will have time scaled from 0 to 180 seconds. You are ready to collect data. 4. Click to begin data collection.

5. Wait about 10 seconds and place the Temperature Probe into the cup of hot water, as shown above. Allow Logger Pro to complete data collection. 6. Notice that the sensor does not read the new temperature instantly; it takes a moment to respond. 7. Now that the run is complete, choose Examine from the Analyze menu. The cursor will become a vertical line. As you move the cursor across the screen, temperature and time values corresponding to the cursor position will be displayed. Move the cursor to the point when the probe was first placed in the hot water. Record that time. Move the cursor to find the highest temperature, and record that time. How long did it take for the temperature sensor to stabilize at the water’s temperature? This tutorial is an example of how easy it is to collect and analyze data with LabPro and a computer. The auto-ID Stainless Steel Temperature Probe simplified the experiment setup, but the use of non auto-ID sensors is almost as easy. All you have to do is connect the sensor or sensors, and open up an appropriate experiment file. Logger Pro software has over 500 experiment files. This set of files also includes experiments in our lab books.

6

Vernier LabPro User’s Manual

Page 11

Using LabPro with a Calculator This section provides the basic steps for collecting data with LabPro and a Texas Instruments graphing calculator. All you have to do is connect the hardware pieces to the calculator, attach one or more sensors, start the calculator program, and you are ready to collect data.4 Note: LabPro cannot be used with TI-Nspire or TI-Nspire CAS handhelds or computer software. There are two software options for collecting data with a calculator: DataMate or EasyData. DataMate supports all analog sensors and the Motion Detector. It comes installed on all LabPro and

CBL 2 interfaces, and can be used with any of these TI graphing calculators: TI-73, TI-73 Explorer TI-82 TI-83 TI-83 Plus, TI-83 Plus Silver Edition5 TI-84 Plus, TI-84 Plus Silver Edition5 TI-86

TI-89 TI-89 Titanium TI-92 TI-92 Plus Voyage 200

EasyData6 comes loaded on TI-84 Plus, TI-84 Plus Silver Edition, TI-83 Plus graphing calculators and TI-84 Plus C. EasyData version 2 supports all analog sensors, Motion Detectors, and Photogates. In addition to supporting LabPro, it can collect data using Vernier USB devices (EasyTemp and EasyLink) and other data collection devices, such as Texas Instruments CBR 2, Texas Instruments CBL 2, or Vernier Go!Motion. EasyData can be used with TI-83 Plus and TI-83 Plus Silver Edition graphing calculators (with operating system version 1.18 or later). TI-84 Plus requires 2.30 or higher.

LabPro interface, TI-83 Plus calculator, and Stainless Steel Temperature Probe

Using DataMate Connecting the Equipment The first step is to connect the calculator and LabPro. 1. Select the proper cradle for your calculator. The off-white cradle accommodates the TI-84 Plus and TI-89 Titanium calculators. The translucent blue-green cradle accommodates all other calculators except for the TI-92, TI-92 Plus, Voyage 200 and TI-Nspire. 4

The DataMate program supports all of the Vernier analog sensors, e.g., Temperature, pH, Force, and the Motion Detector. Calculator support for Photogates, Radiation Monitors, Rotary Motion Sensors, and Drop Counters is through separate programs. See the App and Program Transfer Guidebook for details. 5 For TI-83 Plus, TI-83 Plus Silver Edition, TI-84 Plus and TI-84 Plus Silver Edition, we recommend EasyData. See the EasyData Guidebook for complete details about the EasyData application. 6 See the EasyData Guidebook for complete details about the EasyData application. Vernier LabPro User’s Manual

7

Page 12

2. 3. 4. 5.

Insert the upper end of the calculator into the cradle. Press down on the lower end of the calculator until it snaps into place. Slide the bottom of the cradle onto the top of LabPro until it clicks in place. Plug one end of the LabPro-to-calculator cable into the I/O port of the calculator. Plug the other end into the bottom end of the LabPro.

Calculator Program Installation When it is time to collect data, you will run a program called DataMate on the calculator. Chances are that DataMate is not on your calculator, but it is very easy to install.

1. Prepare the calculator to receive the program:

For the TI-73, TI-73 Explorer, TI-82, and TI-83, turn on your calculator and press 2nd to RECEIVE, then press [LINK] (on the TI-73 press APPS , then select Link…). Press ENTER (Waiting… appears on your screen).

For the TI-86, turn on your calculator and press appears on your screen).

For the TI-89, TI-89 Titanium, TI-92, TI-92 Plus, and Voyage 200, turn on your calculator and make sure that the calculator is on the Home screen. (You do not need to put the calculator into the Receiving mode as is required with the other calculators.)7

2nd

[LINK], then press

F2

(Waiting…

2. Press the Transfer button on LabPro. “Receiving…” followed by a list of the loaded programs (or application) is displayed on the calculator.

3. A “Done” message on the calculator and two beeps from LabPro will indicate the transfer is complete. Press

2nd

[QUIT].

4. Verify that the programs have been successfully loaded.

On the TI-82, TI-83, press PRGM to see DATAMATE and its subprograms. On the TI-73 and TI-73 Explorer press APPS to see DATAMATE. On the TI-86, press PRGM then F1 to see DATAMATE and its subprograms. On the TI-89, TI-89 Titanium, TI-92, TI-92 Plus, and Voyage 200, press 2nd [VAR-LINK] to see DATAMATE and its subprograms.

7 For the TI-89, TI-89 Titanium, TI-92, TI-92 Plus and Voyage 200 we recommend downloading the DataMate App available from www.vernier.com/calcdatamate.html

8

Vernier LabPro User’s Manual

Page 13

Starting the DataMate Program and Preparing to Collect Data Use the following steps to start the DataMate program on your calculator: TI-82 and TI-83 Calculators: Press PRGM , then press the calculator key for the number that precedes DATAMATE (usually 1 ). Press ENTER . An introductory screen will appear, followed by the main screen. TI-73 and TI-73 Explorer Calculators: Press APPS , then press the calculator key for the number that precedes DATAMATE. Press ENTER . An introductory screen will appear, followed by the main screen. TI-86 Calculators: Press PRGM , press F1 to select < NAMES >, and press the menu key that represents DataMate. (< DATAM > is usually F1 ). Press ENTER , and wait for the main screen to load. TI-89, TI-89 Titanium, TI-92, TI-92 Plus, and Voyage 200 Calculators: Press 2nd [VAR-LINK]. Use the cursor pad to scroll down to “datamate”, then press ENTER . Press ) to complete the open parenthesis of “datamate(” on the entry line. Press ENTER . An introductory screen will appear, followed by the main screen. If you are using the DataMate APP, press APPS then scroll to the DataMate application. After the program begins, the calculator will try to communicate with the interface and check for auto-ID sensors. If this communication is successful, the main screen (shown below) will appear. If the calculator cannot establish a link with LabPro, this menu appears. If you choose Continue With Interface, the program will continue trying to communicate with the interface. If the calculator cannot establish a link with LabPro, a Link Error message will appear. Check that LabPro has power and that the link cable is properly connected. This message will continue to appear until the link problem is fixed. This is the main screen that appears after the calculator and interface are communicating. In this example a Stainless Steel Temperature Probe was connected and DataMate automatically identified the Temperature Probe, displayed the channel it was connected to and the current reading. DataMate also sets up a default time graph experiment for auto-ID sensors. In this example, an experiment was set up to collect data for 180 seconds. You are now ready to collect data. Page 12 has a tutorial that uses our Stainless Steel Temperature Probe to investigate the response time of the Temperature Probe.

Vernier LabPro User’s Manual

9

Page 14

Using EasyData Connecting the Equipment EasyData comes loaded on TI-84 Plus, TI-84 Plus Silver Edition, TI-83 Plus graphing calculators and TI-84 Plus C. There are several data-collection devices that can be used with EasyData. These devices include the CBL 2™, LabPro®, CBR™, CBR 2, Go!®Motion, and the Vernier EasyTemp and Vernier EasyLink. For more information on connecting data-collection devices other than LabPro, please refer to the device’s user guide. The first step is to connect the calculator and LabPro. 1. Select the proper cradle for your calculator. The offwhite cradle is for use with the TI-84 Plus. The bluegreen cradle accommodates the TI-83 Plus. 2. Insert the upper end of the calculator into the cradle. 3. Press down on the lower end of the calculator until it snaps into place. 4. Slide the bottom of the cradle onto the top of LabPro until it clicks in place. 5. Plug one end of the LabPro-to-calculator cable into the I/O port of the calculator. Plug the other end into the bottom end of the LabPro.

Starting EasyData and Preparing to Collect Data Press to display the list of available applications, and then select EasyData. The application’s information screen is displayed for about three seconds, followed by the main screen

Each screen displays one or more options along the bottom of the screen. To select an option, press the calculator key directly below the option.

EasyData menus differ slightly among the types of sensors. You can select menu items in the following ways:

Press or to highlight the menu item, and then press to select it.

or

Press the number key that corresponds to the menu item.

You are now ready to collect data. Page 13 has a tutorial that uses our Stainless Steel Temperature Probe to investigate the response time of the Temperature Probe.

10

Vernier LabPro User’s Manual

Page 15

Where to Go Next Since you may want experiments for a particular course, or detailed information on LabPro or calculator programs, the following lab books and manuals provide additional help. They are described in Appendix C. Logger Pro tutorials are a great way to get acquainted with LabPro. Lab Books Physical Science with Vernier Biology with Vernier Advanced Biology with Vernier Chemistry with Vernier Advanced Chemistry with Vernier Physics with Vernier Earth Science with Vernier Real-World Math with Vernier Water Quality with Vernier Nuclear Radiation with Vernier Middle School Science with Vernier Forensics with Vernier Investigating Environmental Science through Inquiry Agricultural Science with Vernier

8

Manuals8 DataMate Guidebook App and Program Transfer Guidebook EasyData Guidebook LabPro Technical Reference Manual

See Appendix C for more information about these manuals.

Vernier LabPro User’s Manual

11

Page 16

Tutorial: Temperature Measurement with DataMate A good way to get acquainted with LabPro is by performing a simple experiment. Using this tutorial, you will take measurements using a Temperature Probe. Just follow the simple steps, and you are well on your way to collecting and analyzing data with a calculator.

MATERIALS TI graphing calculator LabPro interface Vernier Stainless Steel Temperature Probe One 250 mL beaker or cup 100 mL hot water

PROCEDURE 1. Place about 100 mL of hot water into a 250-mL beaker or a cup. 2. Plug the Stainless Steel Temperature Probe into CH 1 on LabPro, and place the Temperature Probe on the tabletop. 3. Start DataMate. Press CLEAR to reset the program. DataMate will detect the auto-ID sensor, set the data-collection parameters, and display the current sensor reading. The experiment will collect temperature for 180 seconds. 4. Select START to begin data collection. 5. Wait about 10 seconds and place the Temperature Sensor into the cup of hot water as shown above. A live graph will appear on the calculator screen. You can either allow DataMate to complete data collection or press the STO key to stop data collection. 6. After the data collection is complete, an autoscaled graph of the data will appear. Notice that the probe does not read the new temperature instantly; it takes a little while to respond. This is a or keys (or the cursor pad on the TI-89, TI-89 characteristic of the sensor. Use the Titanium, TI-92, TI-92 Plus, or Voyage 200) to examine the data points along the displayed curve of temperature vs. time. As you move the cursor right or left, the time (X) and temperature (Y) values of each data point are displayed below the graph. Move the cursor to the point when the probe was first placed in the hot water. Record that time. Move the cursor to find the highest temperature and record that time. How long did it take for the temperature sensor to stabilize at the water’s temperature?

12

Vernier LabPro User’s Manual

Page 17

Tutorial: Temperature Measurement with EasyData A good way to get acquainted with LabPro is by performing a simple experiment. Using this tutorial, you will take measurements using a Temperature Probe. Just follow the simple steps, and you are well on your way to collecting and analyzing data with a calculator.

MATERIALS TI graphing calculator LabPro interface Vernier Stainless Steel Temperature Probe One 250 mL beaker or cup 100 mL hot water

PROCEDURE 1. Place about 100 mL of hot water into a 250 mL beaker or a cup. 2. Plug the Stainless Steel Temperature Probe into CH 1 on LabPro, and place the Temperature Probe on the tabletop. 3. Start the EasyData application. EasyData will detect the auto-ID sensor, set the data collection parameters, and display the current sensor reading. The experiment will collect temperature for 180 seconds. to begin data collection. 4. Select 5. Wait about 10 seconds and place the Temperature Sensor into the cup of hot water as shown above. A live graph will appear on the calculator screen. You can either allow EasyData to complete data to stop data collection. collection or press 6. After the data collection is complete, an autoscaled graph of the data will appear. Notice that the probe does not read the new temperature instantly; it takes a little while to respond. This is a or keys to examine the data points along the characteristic of the sensor. Use the displayed curve of temperature vs. time. As you move the cursor right or left, the time (X) and temperature (Y) values of each data point are displayed below the graph. Move the cursor to the point when the probe was first placed in the hot water. Record that time. Move the cursor to find the highest temperature and record that time. How long did it take for the temperature sensor to stabilize at the water’s temperature?

Vernier LabPro User’s Manual

13

Page 18

Using LabPro Remotely Having a computer or calculator attached to LabPro during data collection is preferable, because it provides much more flexibility in your data collection and provides a screen for immediate feedback of your results. There are times, however, when disconnecting LabPro from the computer or calculator to collect data is useful. For example, remote data collection is perfect for gathering acceleration data on a roller coaster. The following describes remote data collection with Logger Pro 3 on a computer and with DataMate and EasyData on a calculator.

Using Logger Pro 3 Note: If you are running a version of Logger Pro 3 older than 3.3, refer to the program’s Help file. Quick Setup Method Using the Quick Setup Method, you can collect data with LabPro, then retrieve it using a computer running Logger Pro. This method will work only with auto-ID sensors, and it will collect 99 points for each sensor. 1. Set up LabPro for remote data collection a. Connect your auto-ID sensor(s) to LabPro. (Sensors that are not auto-ID cannot be used with this method. The next two methods allow you to use auto-ID and/or non auto-ID sensors.) b. Press the QUICK SETUP button. The yellow LED will blink twice and two beeps will be heard verifying setup. 2. Collect data. a. When you are ready to collect data, press the START/STOP button. You will hear a beep indicating that data collection has begun. The green LED will blink each time a reading is made. b. When data collection is completed, the green LED will no longer blink.9 You do not need to press the START/STOP button to end data collection. (You can, however, stop data collection early by pressing the START/STOP button before data collection is finished.) 3. Retrieve the data. a. When data collection is finished, go to the computer and attach the interface. b. Start Logger Pro. c. If a Remote Data Available window appears, simply click the YES button and choose to retrieve remote data into the current file. If a window does not appear when the interface is reconnected, choose Remote Retrieve Remote Data from the Experiment menu. d. Click to retrieve data into the LabPro Remote data set. You may want to rename the time and data columns after the data are retrieved.

Set Up for Time-Based Method Using the Set Up for Time-Based Method, you will use a computer to set up LabPro, detach it for a real time data collection, and then reattach it to the computer to retrieve the data. This gives you more flexibility than the Quick Setup Method. With this method, you can (a) use any sensors (not just autoID), (b) control the time between samples, and (c) control the number of data points collected (up to about 12,000).

9

The duration of data collection depends on the sensor(s) connected.

14

Vernier LabPro User’s Manual