The text of a manual · part 3 of 6
TA520/530 Data Collection Terminal Technical Reference Manual: Installation
Pages 15 to 29 of 55, from TA520/530 Data Collection Terminal Technical Reference Manual
The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the VeriFone ZON 530
Page 15
Chapter II
Installation
Selecting a Location Select a location for your terminal, which is convenient for your employees and offers adequate ventilation and protection. In general, avoid areas with: *
Excessive heat;
*
Oil or moisture;
*
Excessive dust;
*
Excessive electrical noise caused by air conditioners, motors, fans, or power tools;
*
Direct sunlight;
*
Artificial light that could reflect glare off the display panel;
If building for installation of a TA530 metal terminal, you may want to have a 120 volt AC outlet flush mounted at a height allowing the terminal power pack to be concealed inside the rear cavity with the terminal display at eye level. For proper cable protection a studded mounting wall is preferred, in which communication cables (or telephone lines) can be routed through an access hole in the wall directly behind the terminal.
Package Content Check to make sure you have received all the parts necessary with your TA520 terminal. The parts included are: •
TA520 terminal
•
Power supply
•
Mounting Kit
•
External Serial to Ethernet Converter, if Ethernet Kit purchased
•
Connector(s). Depending on which TA520 terminal type you purchased, you may receive one or more of the following: a. 6 foot, RJ11 to RJ11 cable b. 8 Pin DIN to DB9 Serial Cable c.
50 foot DB9 Serial Extension Cable d. RS485 Converter
9
Page 16
Installing the Terminal The plastic terminal includes a wall mounting kit for easy installation. The metal terminal has a built-in wall mount bracket. 1. Select a location for your terminal that is convenient for your employees use, 4-5 feet from the floor is recommended. The location should provide easy visibility of the display and where clock tones can be easily heard. It has been found by mounting the terminal a little higher than the average shoulder height it forces the employees to reach up to swipe, which increases the read rate of the terminal. 2. The communications cable and power pack cable can be routed through an access hole in the wall directly behind the terminal mount, or allowed to hang down from the bottom of the terminal mount. Please be aware that exposed cables are susceptible to damage and vandalism. NOTE: If using the terminals serial port, the 6' RS232 communications cable is a special cable and must be used. If the terminal is more than 6 feet away from the printer RS232 communications extension cables are available in lengths of 25, and 50 feet. Communication cables are available from your local Time America dealer. The following sections provide installation instructions for both the TA520 plastic and TA530 metal terminals. Follow the instructions for the type of terminal you are using. In most cases the diagrams will reference the TA530 metal terminal, however, the communications and power connections are identical on the TA520 plastic terminal. By using the Transaction Print option you can print transaction lists to a serial printer. In addition to this the terminal allows you to communicate these transactions to the PC software. By transferring the transactions via the Time America PC communications software you gain additional reporting, policy rules, historic data retention, the ability to enter tables on your PC and transfer them to the terminal, and the ability to transfer the transactions to third party software packages. This section also contains instructions on "Connecting your terminal to your PC". This will help you in connecting the terminal to your computer. NOTE: For more information on Time America Time & Attendance Software systems that communicate with the TA520 and TA530, contact your local Time America distributor.
10
Page 17
Connecting the Terminal Power Pack 1. Attach the small plug on the power pack cord to the power pin on the terminal (see figure 5 for steps 1 and 2). 2. Plug the two-prong AC connector from the power pack into an indoor 120-volt AC outlet.
Figure 5: Connecting the Power Pack
Connecting the Battery Backup or Cigarette Lighter Adapter (optional) The operational battery backup and cigarette lighter adapter can replace the terminal power pack. Both units can be mounted in any position, and should be mounted out of the way. NOTE: When the battery backup is disconnected from the 110 Volt AC power source, the on/off switch must be set to the off position. This prevents the battery from discharging, which prolongs battery life.
1.
Attach the small plug on the battery backup or cigarette lighter adapter cord into the power pin on the terminal (see figure 6 for steps 1 and 2).
2.
If using the battery backup, plug the two-prong AC connector from the battery backup into an indoor 120-volt AC outlet. If using the cigarette lighter adapter, plug the cigarette lighter adapter end into a 12 Volt DC auto cigarette lighter.
Figure 6: Connecting the Battery Backup
11
Page 18
Connecting the Terminal to the PC RS-232 Serial Connection The TA520 can be connected with RS-232, which is the simplest connection. Units should come with an 8 pin DIN to DB9 cable and a 50-foot extension cable.
Figure 7: RS-232 Serial Connection
1. Plug the 8-pin DIN end of the cable into the female 8-pin DIN connector on the top of the TA520 unit next to the power connector. 2. Plug the DB9 end of the cable into the serial port of the computer. NOTE: If the computer doesn’t have a DB9 port available, you must request an 8 pin DIN to DB25 pin cable instead.
12
Page 19
Modem Connection 1. The computer that will poll the terminal must have a modem installed. The computer cannot access the Internet via modem and communicate with a modem terminal at the same time. 2. Locate the Standard RJ11 Cable supplied with the clock. 3. Plug into either RJ11 jack on the clock, and into the standard analogue phone connection.
Figure 8: Modem Connections
13
Page 20
Connecting the RS485 LAN (TA5XXL & TA5XXLB) 1. Connect the RS485 converter to the PC serial port. 2. Connect one end of the standard RJ11 cable to the modular jack on the converter. Connect the other end to the LAN distribution box. 3. Connect Cat 5 cable to the distribution box pins #2 & #5 (black & yellow.) 4. Connect the other end of the Cat 5 cable to the next distribution box using the same color code and pin out. 5. Connect one end of the standard RJ11 cable to the modular jack on the distribution box. Connect the other end to the clock. 6. Continue steps 3-5 for each LAN clock on the multi-drop.
Figure 9: LAN Connections
14
Page 21
TCP/IP Connection The TA520 can be connected to a TCP/IP network by using the Etherlink Converter. 1. After configuring the IP Address in the Etherlink Converter (see below), attach to the Etherlink Converter to the network by plugging in the 10/100BaseT Ethernet cable 2. Attach the Serial cable provided to the 8pin DIN port on the terminal and the DB9 connector to the Etherlink Converter. 3. Plug the other end of the cable into the wall (or hub) to connect to network. 4. Power on the Etherlink Converter
Figure 10: TCP/IP Connection
Installation of an IP Address using Direct Connection 1. Remove power from the Etherlink Converter 2. Place the dipswitches in the 1-DOWN 2-UP positions on the Etherlink Converter 3. Connect the Etherlink Converter to a PC using the DB9 Female-to-DB9 Female serial cable provided 4. Start the HyperTerminal program in Windows on the PC. This program is found under Start->Programs->Accessories->Communication a. Make sure the Etherlink Converter is not powered on b. Place the name Ethernet in the name box and press ENTER c.
Change the Connect Using window to reflect DIRECT TO COMM1 or the respective comm. port being used and select OK d. Set BITS PER SECOND to 9600, DATA BITS to 9, PARITY to NONE, STOP BITS to 1, and FLOW CONTROL to NONE and select OK e. Power on the Etherlink Converter 5. Follow menu options to change IP information
15
Page 22
Installation of an IP Address Using a Web Browser 1. Connect the Etherlink Converter to the LAN using a standard 10/100baseT network cable 2. Power up the Ethernet Converter with the dipswitches set in the 1-DOWN 2-DOWN positions 3. Start the web browser and type the IP Address of the selected Etherlink Converter (default is 192.168.1.200). This procedure will only work if the address of 192.168.1.200 is not currently in use on the network, and is part of the network of the computer that is attempting to communicate with it. 4. A Graphical User Interface will appear in the browser window allowing changes to be entered.
Connecting the P250, P600 or 80 Column Printer (optional) If you are using an 80-column printer, please refer to the owner’s manual for specific printer setup instructions. It should, however, follow the same basic steps as the P250 and P600 printers. WARNING: When using an 80-column printer the printer must contain at least an 8K buffer. 1. Select a convenient location for the printer. Usually this is away from the employees on a supervisor's desk. 2. Follow the instructions supplied with the printer for installing the paper and ribbons. If you are using a standard 80-column printer or sharing a P250 connected to a VeriFone credit card verifier, skip to step 6. 3. Route the power and communications cables to the printer. The short mini-DIN on the printer cable plugs into the connector marked "RS232". Be sure to align the key (a small recess) on the connector with the socket in the terminal. The other end connects with the DB25 connector on the RS232 communications cable supplied with the terminal. Please note that exposed cables are susceptible to accidental damage and vandalism. See figure 11. 4. Plug the printer power supply into the wall outlet. Do not plug the power pin into the printer at this time. 5. Making sure the O on the power switch is down (turned OFF), connect the power pin and RS232 cables to the respective marked ports on the back of the printer. After connecting the power pin press the power switch to the "1" position. The print head will align itself and the green "POWER" indicator will be on. You are now ready to print reports. If the green power light does not come on, press the power switch to the "O" position and check your power connections (step 3), then repeat steps 4 and 5. 6. If you are using a standard 80 column serial printer the 6 foot RS232 cable will connect directly to your printer. If the 25-pin cable end is not the same as the printer's 25-pin connection, you may obtain a DB25 serial adaptor (male-female gender changer) at your local computer store. If you are using the Parallel Interface Converter to a parallel printer, please see Appendix K for instructions on its 16
Page 23
connections. If you wish to have your terminal share an existing P250 serial printer that is connected to a VeriFone credit card verifier you will need to purchase a special Y cable from your local Time America dealer. Appendix J documents the Y cables connections. 7. At this time you may want to run a test printout; see the "RUNNING PRINTOUTS" section of this manual. If you have problems getting the terminal to print, repeat steps 2 through 5 and consult your printer manual for more detailed instructions.
Figure 11: Serial Printer Connections
17
Page 24
Connecting the Bar Code Wand and Slot Reader (optional) 1.
Connect the plug on the bar code wand to the 6-pin DIN port on the terminal (see figure 12).
2.
If you have a TA530 metal unit, squeeze the two halves of the plastic strain relief tightly around the bar code wand cable approximately 12 centimeters from the connector. Slide the strain relief into the bottom of the small U-channel on the terminal's metal case, using the grooves molded into the strain relief (see figure 12). NOTE: Since the terminal performs the bar code description, the slot or gun reader must be in "Bar Code Wand Emulation Mode".
Figure 12: Connecting the Bar Code Wand
18
Page 25
Connecting the Signal Enhancer (optional) To support the Signal Enhancer the terminal must contain the Bell and Access options. 1.
Connect the plug on the Signal Enhancer into the 6-pin DIN port on the terminal (see figure 13).
2.
If you have a TA530 metal unit, squeeze the two halves of the plastic strain relief tightly around the signal enhancer cable approximately 12 centimeters from the connector. Slide the strain relief into the bottom of the small U-channel on the terminal's metal case, using the grooves molded into the strain relief (see figure 13).
NOTE: When using the Signal Enhancer, Bells and Access cannot be used since the terminal uses the bell and access signals to operate the Signal Enhancer.
Figure 13: Connecting the Signal Enhancer
19
Page 26
Connecting the Signal Control Relay (optional) To support the Signal Control Relay your terminal must contain the Bell and Access options. 1. Connect the plug on the Signal Control Relay into the 6-pin DIN port on the terminal (see figure 14). 2. The Signal Control Relay controls two types of output - dry contact and 110 VAC outlet. The contact is operated from the terminals voltage. In order for the 110 VAC outlet to work, plug the three-prong AC connector from the relay into an indoor 120-volt AC outlet.
NOTE: When using the Signal Control Relay, the Signal Enhancer cannot be used since the terminal uses the bell and access signals to operate the Signal Enhancer. For further information on how to set the directional switch on the relay, see Appendix I.
Figure 14: Signal Control Relay Hookup
20
Page 27
Mounting the TA520 Plastic Terminal
Figure 15: TA520 Wall Mounting Diagram
1. Position the Wall Mount Bracket on the wall and mark the two screw mounting holes. The bracket may be positioned over an access hole in the wall for communication cable and power cable. 2. Set the Wall Mounting Bracket aside and drill the appropriate size pilot holes for the mounting screws. If you are using screw anchors to attach the terminal to drywall or concrete, be sure the anchors fit snugly in the holes with their tops flush with the wall. 3. Position the Wall Mounting Bracket on the wall and screw it firmly in place. Be sure the communications and power cables coming out from the wall, or up from the ground, protrude through the opening in the top of the mount. 4. Plug the power supply into the wall outlet. Do not plug the power pin into the terminal at this time. 5. Place the terminal over the mounting pins, and slide the terminal down until it locks into place. Insert the communications cable into the proper terminal communication port. 6. Insert the power pin into the terminals power connector. The display will light up; if it does not check your power cable connections. 7. Lower the wire shroud in place and push it backwards towards the wall, locking it in place. Then install the two security screws with a T-15 Torx screwdriver. 8. Peel the protective covering from the display.
21
Page 28
Mounting the TA530 Metal Terminal The TA530 comes with an integrated metal wall mount bracket. The communication cables can be routed through an access hole in the wall directly behind the terminal. You can also route the cables through 2.54 cm diameter (1") conduit using the U-shaped cutouts on the bottom of the terminal. Figure 16 shows the requirements for positioning the wall plate and conduit in relation to the AC outlet and cable conduit.
Figure 16: TA530 Mounting Specifications
1. Using a Phillips screwdriver, loosen the screw on the bottom of the terminal and carefully remove the terminal from the Wall Mounting Bracket. 2. Position the Wall Mounting Bracket on the wall and mark the four screw holes. This bracket may be mounted over an existing duplex power outlet or an access hole in the wall, which the communications cables will come through (see figure 16). 3. Set the Wall Mounting Bracket aside and drill the appropriate size pilot holes for the mounting screws. If you are using screw anchors to attach the terminal to drywall or concrete, be sure the anchors fit snugly in the holes with the tops flush with the wall.
22
Page 29
4. Position the Wall Mounting Bracket on the wall. Be sure any communications cables coming out from the wall run through the opening in the bracket. 5. If you are using conduit, insert the threads on the end of the conduit into the conduit flange before screwing the mounting bracket in place.
Figure 17: TA530 Wall Mounting Diagram
6. Screw the mount firmly in place. If you are using conduit, thread and tighten the nuts that secure the conduit to the mount. 7. Pull the cables through the conduit or wall until their ends stick out approximately 12 centimeters. 8. Plug the power supply or operational battery backup into the wall outlet. Do not plug the power pin into the terminal at this time. 9. Holding the terminal close to the wall plate, insert the communications cable into the proper communication port on the underside of the terminal. 10. Connect the other ends of the cables to the proper outlet or device (see corresponding connecting section of this manual). If you are using a Bar Code Wand, Signal Control Relay, or Feedback Enhancer, connect it at this time. 11. After checking all of your connections, insert the power/ battery backup cord into the terminals power pin and the wall plate cable clip. The display will light up; if it does not check your power cable connections. 12. Place the terminal over the mounting pins on the wall plate and slide it down until it locks in place. 13. Install the security screw in the bottom of the terminal with a T-20 Torx screwdriver. 14. Peel the protective covering from the display.
23