TA520/530 Data Collection Terminal Technical Reference Manual: Overview

Pages 7 to 14 of 55, from TA520/530 Data Collection Terminal Technical Reference Manual

The original document is the PDF (4.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the VeriFone ZON 530

Page 7

Chapter I

Overview

Time America Inc. has been an innovator in the development of computerized time & attendance and data collection systems. Since 1987 we have constantly explored new ways to do a better job of collecting and processing your data. We are committed to provide powerful systems that are simple to use. What sets Time America apart from all other time & attendance manufactures is our High Quality Products, Superior Service, and our Research and Development process. We are kept on the leading edge of technology through creativity and the relentless efforts of many people. Contributions made by those using our product are essential. Product and system enhancement ideas have come from many customers using our products in their businesses. We welcome and encourage your comments and suggestions. Tell us what you'd like to see in future versions, what's important, what's helpful, and what's not. Tell us also what you think of our instructional manuals and how we can improve them. We appreciate your purchases and are confident that TA520 or TA530 by Time America will be the solution to your data collection needs.

What's In This Manual? Chapter 1

Overview: This section tells you about Time America and what information is offered in this Operating Manual. It also describes the TA520/530 and its functions.

Chapter 2

Installation: This section describes the connection of the communication and peripheral cables. The physical installation of the TA520 and TA530 terminal is also described.

Chapter 3

Basic Operation: This section describes how to use the swipe reader, keypad, and standard terminal function keys.

Chapter 4

Modes Of Operation: This section describes the different modes of operation that are available in the standard terminal. These modes include Configuration, Supervisor, and Diagnostics.

1

Page 8

FCC (15) Compliance This equipment complies with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide protection against interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference with television or radio reception. Users should take whatever measurers are required to eliminate the interference. If this equipment causes interference, try to current the problem by: A. Reorienting the receiving antenna B. Relocating the terminal with respect to the receiver with which it interferes. C. Plugging the terminal into a different AC outlet, and putting the terminal and receiver on different branch circuits. Warning: This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the manufacturer's instructions, it may cause interface with radio and television reception.

FCC (68) Compliance This equipment complies with Part 68 of FCC Rules. Upon request, furnish the following information to the telephone company (telco). A. B. C. D. E.

Manufacturer: VeriFone, Inc. Models: ZON 540 (TA520L), ZON 540M (TA530L), ZON 541 (TA520LB), ZON 541M (TA530LB), ZON 530 (TA520M), ZON 530M (TA530M), ZON 531 (TA520MB), ZON 531M (TA530MB). FCC registration number: B326BQ-14432-DT-E Ringer equivalence: 0.5A USOC modular telephone jack: RJ11

Attention Canadian Users Make sure your local telephone company will permit you to install this equipment. Use only the connection methods accepted by your telephone company. You should be aware, however, that compliance with the above conditions might not prevent degradation of service in some conditions. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Equipment malfunctions, or any equipment repairs and alterations made by a user, may cause the telephone company to request to disconnect the equipment. For your own protection, make sure that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas or noisy electrical environments.

2

Page 9

Notice: The Canadian Department of Communications (DOC) label identifies certified equipment. This certification means the equipment meets certain telecommunications network protective, operational and safety requirements. The department does not guarantee the equipment will operate to a user's satisfaction. CAUTION: Do not attempt to make such connections yourself; contact the appropriate electrical inspection authority or electrician.

Terminal Load Number The load number (LN) indicates the amount of load the terminal will add to a telephone loop. The loop may consist of any combination of devices, provided the sum of their load numbers does not exceed 100. If the sum exceeds 100, the loop may be overloaded. An alphabetic suffix is also specified in the load number for the appropriate ringing type (A or B), if applicable. For example, LN=38B designates a load number of 38 and a B-type ringer.

Service Unless otherwise instructed in this manual, do not, under any circumstances, attempt any service, adjustments or repairs on this unit. Call your local authorized TIME AMERICA dealer for repair or replacement.

About This Manual This manual is a reference guide for installing your TA520 or TA530 terminal. It also describes some of the basic operations of the unit. However, the actual operations and procedures used with the terminal depends on the program loaded into the terminal. A program is a set of instructions stored in your terminal. All TA520 and TA530 terminals are equipped with standard programming. However, your terminal may also be supplied with a custom program to perform special transactions used by your company.

3

Page 10

Hardware Overview The TA520 and TA530 are powerful data collection terminals capable of gathering, processing and transferring information at a high speed. The TA520 and TA530 perform identical functions, the difference being, the TA520 has a hardened plastic case and the TA530 has a metal case. The unique capabilities of these devices make them ideal for automating many costly manual procedures or as alternatives to expensive and bulky, full-sized computer terminals. Because of their small size and versatile communications, these terminals can be utilized in practically any location or working environment. The TA520 and TA530 are ideal for many diverse applications including, time and attendance tracking, order entry, inventory, process tracking, access control, and other transaction processing. The TA520 and TA530 communicate with a remote host computer via cable or telephone line, to perform transactions in a store forward mode. All terminals can communicate via RS232 serial communications. The TA520M, TA520MB, TA530M, and TA530MB contain an internal modem, which can communicate transactions over a standard phone line, at speeds up to 1200 baud. The TA520L, TA520LB, TA530L, and TA530LB contain an RS485 LAN port, which allows multiple terminals to communicate transactions over a single two-wire communications cable, at speeds up to 19200 baud. Badge Slot Display Panel

Wall Mount Slots Communications Ports

Keypad

Name Plate Power Pin

Conduit Knock-Outs Figure 1: TA530 Time & Data Terminal

Display Panel The 16-character alphanumeric display panel (see figure 1-1) provides you with the visual prompts and information needed to operate the terminal. The vacuum florescent display is easy to read, even under poor lighting conditions. It displays fully formed numerals, upper case letters, and several punctuation symbols.

4

Page 11

Keypad The keypad (see figure 1-2) contains 16 keys, which can be used to enter alphabetical data, numeric data, and to initiate many different operations. The actual functions initiated by these keys will vary depending on your terminals programming.

Figure 2: TA530 Keypad

Card Reader All terminals feature an ABA track 2 card reader (slot on the terminals right side, see figure 13) for reading magnetic card data. An optional track 1-card reader is available. The TA520 and TA530 MB and LB also include a slot bar code reader to read 3 of 9 or optionally 2 of 5 bar code badges. Both readers allow you to use a variety of card thicknesses. See Fast Faxes 21 & 29 for card specifications. You can enter identification information by simply sliding a card through the slot. The card reader will read the encoded data off the magnetic stripe or bar code. To slide the card through the card reader, place it at the top of the slot with the magnetic stripe/bar code away from you. Magnetic stripe facing to the right or bar code facing to the left. Slide the card down without stopping, keeping the card firmly pressed to the back of the reader (see figure 3).

Bar Code (faces to the left) Magnetic Stripe (faces to the right)

Figure 3: TA530 Card Reader

5

Page 12

Serial Port All terminals have one serial port for communicating with other devices (see figure 4). The RS232 serial port has an 8-pin DIN connector for direct connect with a computer. This port is also used to support the optional Serial Printer or external modem. The terminals serial port can communicate at up the 19,200 baud.

8-Pin DIN RS232 Serial Port

6-Pin DIN Accessory Port

Power Pin

RJ11 Telephone Jacks Internal Modem or RS485 LAN

Figure 4: TA530 Inner Cavity

Accessory Port All terminals have one accessory port for communicating with optional devices (see figure 4). This port utilizes a 6-pin DIN connector for connecting a bar code wand or bar code slot reader, and up to two signal control relays. The signal control relays are used to turn on/off such devices as bells, and door strikes for access control. To connect more than one device to this port, you will need a 6-pin Din Y cable.

Telephone Jacks Each terminal contains two RJ11 modular telephone jacks (see figure 4). You can connect the RJ11 cable (telephone line) to either jack. These jacks are used for different types of communications (Modem or LAN), depending upon which model of terminal you are working with. The TA520M, TA520MB, TA530M, and TA530MB use the RJ11 jacks to connect to the internal modem. A modem (Modulator/Demodulator), converts electronic data into tones that can be sent great distances over telephone lines. The M and MB models use a Telco Bell 212A, 1200 baud internal modem for simple and automatic telecommunications with a host computer. Either telephone jack can be used for communications. The second jack allows a standard telephone to 6

Page 13

share the same line. When selecting your modem terminal, be sure that it's modem is compatible with the host computer. Note: Each terminals serial port can be used to connect an external modem up to 9600 baud. See the connecting an external modem section of this manual.

The TA520L, TA520LB, TA530L, and TA530LB use the RJ11 jacks to connect to the terminal to an RS485 LAN network. An RS485 LAN (Local Area Network) is a direct connects which allows many terminals to use the same line. This allows terminals to be located up to 5000 feet from the host computer. Either telephone jack can be used for communications.

Power Pin The cord from the power pack plugs into the power pin on the terminal (see figure 4). Each terminal comes with a power pack that plugs into a standard 120 volt, 60 cycle, AC outlet. Power packs for other AC power configurations are available as options.

Battery Backup

(Standard)

Your terminal comes standard with a built-in battery-providing backup power to preserve data in RAM for up to 7 months, in event of power failure. This type of battery backup does not support terminal operations.

Battery Backup

(optional)

When it is necessary to maintain terminal operation when power is cutoff, an operational battery backup is available. This battery backup provides complete terminal operation including communications and bar code wand scanning. This battery backup offers an excellent form of power surge protection, because the terminal is always running off the DC battery. Line power is then used to trickle charge the battery.

Communications Converter

(optional)

The RS232 <--> RS485 Communications converter allows a LAN to be run off a computers serial port. A second version called the “Smart Converter" allows a LAN to be driven from an external modem. This is useful for a remote LAN that will be dialed up using an external modem. See Appendix E - G for diagrams on the different types of LAN converters.

Cigarette Lighter

(optional)

The cigarette lighter adapter plugs into any standard automobile cigarette lighter, to provide a measure of portability to the terminal. For instructions on how to hook up the Cigarette Lighter Adapter, see "Connecting The Battery Backup or Cigarette Lighter Adapter.”

7

Page 14

Bar Code Wand

(optional)

Bar codes are a series of vertical lines on a label that are used to identify an item. These codes are read by drawing a special wand across the bar code. The bar code wand connects to the 6pin DIN port on the terminal. The bar code wand can be used to enter bar code numbers for job tracking and inventory control.

Bar Code Slot Reader

(optional)

The bar code slot reader is used to read bar codes off a badge or card. These cards/badges are read by sliding the card/badge through the slot with bar code facing the reader’s window. The bar code slot reader connects to the 6-pin DIN port on the terminal. The bar code slot reader can be used for access control or in place of the terminals internal bar code slot reader, when high resolution or infrared bar codes are used.

Transaction Print

(optional)

The transaction print option allows the terminal, through supervisor mode, to directly print out transaction lists in a variety of formats. This option also allows you to print out transactions as they occur, giving you an immediate hard copy backup. The transaction print option uses the terminals serial port; therefore, this option can only be used if you are not using the 8-pin DIN port for communications. You can print to any 40-column serial printer, or parallel printer by using a serial to parallel interface converter.

Signal Control Relay

(optional)

Where bell ringing or access control is required, the Signal Control Relay is used to control a 110 Volt AC or contact closure circuit. The terminal can tell the Signal Control relay to turn this circuit on/off at programmed times of the day for a programmed duration (Bell Control) and by an authorized employee number at the proper time of day and day of week (Access Control). The signal Control Relay connects to the 6-pin DIN port on the terminal. Each terminal can support up to two relays (one for bells and one for access), by using a 6-pin DIN Y cable. Appendix I gives detailed instructions on the relays operational settings. Note: Your terminal must contain the Bell and Access Control EPROM option to support the Signal Control Relay. It must be wired for Bells/Access.

Signal Enhancer When installing the terminal in noisy environments, the terminals audio and feedback (accept/reject tones) may be drowned out. The Signal enhancer utilizes the Bell and Access options of the terminal to create a louder buzzer on the Signal Enhancer Box. Additional feedback is also provided by a green accept and red reject light. The Signal Enhancers buzzer and lights mimic the terminals standard accept and reject tones. The Signal Enhancer option uses the terminals Bell and Access signals; therefore, this option can only be used if you are not using Bell and Access control. Note: Your terminal must contain the Bell and Access Control EPROM option to support the Signal Enhancer. It must be wired for Bells and Access.

8