Manual · VeriFone
TA520/530 Data Collection Terminal Technical Reference Manual
Manual55 pagesPDF 4.1 MB
Technical reference manual for the Time America TA520/530 time and data terminals, made by VeriFone as the ZON 530 family.
Covers · 1 model
The models it covers
Summary
What is in it
Time America's technical reference manual for the TA520 (plastic case) and TA530 (metal case) data collection terminals, in LAN, modem and built-in bar code reader versions. Its FCC page lists VeriFone as the manufacturer and gives the matching ZON model numbers, such as ZON 530 for the TA520M. It covers the display, keypad, card reader and ports, installation and wiring to a PC by RS-232, modem, RS485 LAN or TCP/IP, printers, wands and relays, mounting, basic operation, configuration and supervisor modes, and clock functions.
Its parts
- Overview
- Installation
- Basic Operations
- Modes of Operation
From the manual
Key facts from this manual
Each line names its page in the PDF.
Time America technical reference manual (revision 4.7, June 2002) for the TA520 and TA530 data collection terminals, in LAN versions (TA520L, TA530L, TA520LB, TA530LB) and modem versions (TA520M, TA530M). Its FCC page names VeriFone as the manufacturer and gives ZON 530 as the model name of the TA520M modem terminal. It covers the hardware, installing the terminal and its options, using the card reader and wand, and the specifications.
- Device
- Data collection terminal for time and attendance, order entry, inventory and access control; TA520 in a plastic case, TA530 in a metal case p. 10
- Modem
- M and MB models: internal auto-answer Bell 212A modem, 1200 baud, on two RJ11 jacks p. 12, 54
- Serial port
- 8-pin DIN RS232 port on all terminals, for a PC, serial printer or external modem p. 12
- Display
- 16-character vacuum fluorescent alphanumeric display p. 54
- Keypad
- 16-button silicon-rubber keypad with color coded keys p. 54
- Card reader
- ABA track 2 magnetic stripe, track 1 optional; MB and LB models add a slot bar code reader for 3 of 9 (2 of 5 optional) p. 11
- Processor and memory
- Z-80 microprocessor; 32K EPROM, 32K RAM p. 54
- Power
- Power pack for 120 volts AC, 60Hz; 10W consumption p. 13, 55
- Battery backup
- Built-in battery keeps RAM data up to 7 months without running the terminal; operational battery backup optional p. 13
- LAN
- L and LB models: RS485 LAN on the RJ11 jacks, up to 19200 baud, terminals up to 5000 feet from the host p. 10, 13
- Accessory port
- 6-pin DIN for a bar code wand or slot reader and up to two signal control relays (with a Y cable) p. 12
- Environment
- Operating 0-40 C (32-104 F); storage -18 to 70 C; humidity 5% to 90%, non condensing p. 55
- Signal control relay
- Dry contact up to 5 amps at 110v; 110v outlet up to 10 amps p. 52
- In the box
- TA520: terminal, power supply, mounting kit; by type a 6 foot RJ11 cable, 8 Pin DIN to DB9 serial cable, 50 foot DB9 extension or RS485 converter p. 15
What this manual walks you through
- Choosing a location for the terminal p. 15
- Connecting the power pack, battery backup or cigarette lighter adapter p. 17
- Optional accessories: battery backup, converters, wand, slot reader, transaction print, relay p. 13, 14
- Swiping a badge in the internal card reader p. 35
- Using an external bar code wand or card reader p. 36
- Setting the signal control relay for bells and access control p. 52
- Pin functions of the RS232 8-pin DIN connector p. 55
Good to know
- Set the battery backup switch to off when it is disconnected from AC power, so the battery does not discharge. p. 17
- The signal control relay and signal enhancer need the Bell and Access Control EPROM option. p. 14
- The 6 foot RS232 communications cable is a special cable and must be used with the serial port. p. 16
- Transaction print uses the serial port, so it works only when that port is not used for communications. p. 14
- The default program accepts a five-digit badge; another length shows INVALD BADGE. p. 35
Questions this manual answers
What is the VeriFone ZON 530?
The FCC page of this manual lists the ZON 530 as the model name of the Time America TA520M, a modem data collection terminal in a plastic case. p. 8, 10
What modem is in the TA520M or ZON 530?
An internal auto-answer Bell 212A modem at 1200 baud, connected through RJ11 jacks. p. 12, 54
Does the terminal lose its data in a power failure?
A built-in battery keeps data in RAM for up to 7 months, but it does not run the terminal; an optional battery backup keeps it working. p. 13
Why does the terminal beep 3 times and show PLEASE TRY AGAIN?
The card was not read. Check the position of the stripe or bar code and slide the card through again; if it persists, the card may be damaged. p. 35
What bar codes can the TA520/530 read?
3 of 9 bar codes; 2 of 5 is optional. p. 36
Contents
Chapters and sections
Each line opens the PDF at its page.
- Overview7
- Installation15
- Selecting a Location15
- Package Content15
- Installing the Terminal16
- Connecting the Terminal Power Pack17
- Connecting the Battery Backup or Cigarette Lighter Adapter (optional)17
- Connecting the Terminal to the PC18
- Connecting the P250, P600 or 80 Column Printer (optional)22
- Connecting the Bar Code Wand and Slot Reader (optional)24
- Connecting the Signal Enhancer (optional)25
- Connecting the Signal Control Relay (optional)26
- Mounting the TA520 Plastic Terminal27
- Mounting the TA530 Metal Terminal28
- Basic Operations30
- Modes of Operation38
The whole text · 6 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file