Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 15

TRANZ 380 Reference Manual, pages 61 to 70

Pages 61 to 70 of 148

The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the VeriFone Tranz 380

Page 61 read from a scan by OCR; it may hold reading errors

Delay Before Auto Answer

Encrypted Working Key/ Master Key Pointer

RECALL, Set Clock, Unit-to-Unit Restriction Flag

Application ID

6. Terminal Parameters

Memory Location: 0015 Character Type: Numeric Field Length: 3

This parameter allows you to set the delay in seconds before the terminal answers an incoming call after the first ring. The maximum value is 999 seconds. Memory location 0038 must contain a control string before the auto answer feature will be enabled.

Memory Location: 0016 Character Type: Alphanumeric Field Length: 18

This parameter allows you to obtain an encrypted PIN block from a VeriFone PIN pad when the *H command is executed. The terminal expects location 0016 to contain the Encrypted Working Key and a pointer to which of the ten PIN pad working keys is to be used. The format of the data in location 0016 is as follows:

0016=nnnnnnnnnnnnnnnn-x where: n = Encrypted Working Key hexadecimal digit - = Mandatory data separator x = Master Key Pointer (0-9)

Memory Location: 0017 Character Type: Numeric Field Length: 1 character

This parameter allows you to protect memory from unauthorized or accidental alteration by putting a password restriction on the RECALL, clock setting and terminal-to-terminal download functions. if you enter a non-zero number in location 0017, the system password Z66831 will be required for these functions. If you enter a zero for location 0017, the password will not be required.

Memory Location: 0019 Character Type: Alphanumeric Field Length: Up to 7 characters

The application ID identifies a custom application file name to the download computer. With this ID, the download computer can select the correct application and download it to the terminal. Obtain the application ID from the person responsible for maintaining the download computer.

If the memory location is empty, the terminal will automatically prompt you for the download data.

Page 62 read from a scan by OCR; it may hold reading errors

idle Prompt

TRANZ 380 Reference Manual

Memory Location: 0030 Character Type: Alphanumeric Field Length: Up to 16 characters

The standard TRANZ 380 idle prompt is the day of the week, date and time in the following format:

WWW MM/YY hh:mma where:

Www 3-character day of week

MM = numeric month YY = numeric year hh = hours in 12-hour format : = "blinking" colton mm = minutes a = AM or PM indicator

You can change the display by entering a new prompt in memory location 0030. Any message can be entered, such as "READY" or "HELLO," in up to 16 alphanumeric characters. If memory location 0030 is empty, the terminal will display the default idle prompt: day of week, date and time. If the first character in memory location 0030 is a "." (period), the operating system will use the remaining characters as format information for the date and time. The characters are described in the TCL command J. (See Appendix D for how the TCL command J has been enhanced for the TRANZ 380.) The time may be represented in either a 12- or 24-hour format. Example: to display "MY BANK hh:mm" where:

"hh" is hours in a 24-hour format, ":" is a blinking colon and "mm" is minutes The user would store the string: ".UMY UBUAUNUK SKRTE" where:

. time format information flag UM

= M Y = Y space = space UB = B UA = A UN = N UK = K space = space S) = suppress leading zeroes K = hours in 24-hour mode R = allow leading zeroes T = blinking colon E = minutes

Page 63 read from a scan by OCR; it may hold reading errors

Function Keys #1-6, #9

Out of Memory Control String

Auto Answer Control String

Memory Dial Phone Numbers

6. Terminal Parameters

Memory Location: 0031-0036, 0039 Character Type: Alphanumeric Field Length: 120 characters

These parameters can be used by an application to perform local functions. Each function key is accessed by pressing [FUNC/ENTER] followed by the appropriate numeric key ( [1], [2], [3]...[6], [9] ). This then executes the control string in the corresponding memory location (0031, 0032, 0033... 0036, 0039).

Memory Location: 0037 Character Type: Alphanumeric Field Length: 120 characters

This parameter can be used by the application to automatically delete old data if the TRANZ 380 detects that all available memory is already in use.

This location is usually empty and must be custom programmed for each application to utilize this feature.

Memory Location: 0038 Character Type: Alphanumeric Field Length: Up to 120 characters

This parameter enables the TRANZ 380 to respond to an incoming telephone ring and communicate with another dial-up device.

This memory location is usually empty and needs to be programmed for the auto answer control string to support communication between the TRANZ 380 and the remote dial-up device.

Memory Location: 0040-0099 (General Records) Character Type: Alphanumeric Field Length: Up to 60 characters

Caution: Some of these memory locations may contain application program data. Refer to your application reference manual to see which of these locations are available before entering memory dial phone numbers.

For convenient memory dialing you can store frequently called telephone numbers in the memory locations reserved for general records. To use this feature, press the [0] key after the idle prompt and then enter the memory location that contains the phone number you want to dial.

The phone number may contain up to 60 characters including the numerals 0 through 9 and a two-second pause (-) character.

You can enter an access code with the phone number and, if needed, separate the two by inserting one pause character for each two-second pause between them. For example, if you enter the common outside line access

6-9

Page 64 read from a scan by OCR; it may hold reading errors

Printer Type

Printer 250 Paper Advance

Generic Printer Baud Rate

TRANZ 380 Reference Manual code "9" followed by a dash (-) and the phone number, the terminal will dial the 9, pause two seconds, then continue dialing the phone number.

Note: Do not add a dash (-) in the middle of a phone number. This will create an unnecessary delay in dialing the number. The pause character is intended only for use between access codes and phone numbers.

Memory Location: 0950 Character Type: Numeric Field Length: 1 character

This parameter allows you to specify the type of printer you have connected to the TRANZ 380 terminal. There are currently four options.

Entry Printer Type fe) No printer

1 Generic roll printer

2 Printer 250 / Printer 600 3 Printer 150 / Printer 500

Memory Location: 0951 Character Type: Numeric Field Length: 3 characters

This parameter allows you to specify the number of line feeds a Printer 250 roll printer will automatically advance after printing a receipt or transaction record. The default number of line feeds is 6. However, you can enter any number from 1-255.

Memory Location: 0952 Character Type: Numeric Field Length: 1 character

This parameter specifies the serial port baud rate if the printer type is set for generic roll printer (0950=1).

Entry Baud Rate

300 baud (defauit) 600 baud

1200 baud

2400 baud

4800 baud

9600 baud

19200 baud

Aahoan-o

Page 65 read from a scan by OCR; it may hold reading errors

Generic Printer Data Format

Generic Printer Handshake

Bell/CCITT Mode

Dial-Up Line Upload/Download Speed

6. Terminal Parameters

Memory Location: 0953 Character Type: Numeric Field Length: 1 character

This parameter specifies the data format for the serial port if the printer type is set for a generic roll printer (0950=1).

Entry Data Format 0 7 data bits, even parity, 2 stop bits (default) 1 8 data bits, no parity, 2 stop bits

Memory Location: 0954 Character Type: Numeric Field Length: 1 character

This parameter determines the type of handshaking used on the serial port if the printer type is set for generic roll printer (0950=1).

Entry Handshake 0 Hardware (CTS/RTS default) 1 None

Memory Location: 0958 Character Type: Numeric Field Length: 1 character

This parameter allows you to set the internal modem to either Bell or CCITT mode.

Note: This feature is not available for all versions of the TRANZ 380. Entry Mode

<empty> Bell 0 Bell 1 CCITT

Memory Location: 0960 Character Type: Numeric Field Length: 1 character

This parameter is for specifying the communications speed (baud rate) used when uploading or downloading information over a public dial-up line. The baud rate you specify must match the baud rate used by the device your TRANZ 380 is communicating with.

If the memory location is empty, the terminal will automatically prompt you for the download data.

Page 66 read from a scan by OCR; it may hold reading errors

Auto Answer Speed

Auto Answer Processing

Auto Answer Packet Inactivity Timeout

TRANZ 380 Reference Manual

Entry Baud Rate

<empty> 300 Baud 1 300 Baud 2 1200 Baud

Memory Location: 0965 Character Type: Numeric Field Length: 1 character

This parameter is used for specifying the communications speed (baud rate) used when the host computer calls the terminal.

Entry Baud Rate

<empty> 300 Baud 1 300 Baud 2 1200 Baud

Memory Location: 0966 Character Type: Numeric Field Length: 1 character

This parameter allows control over how the terminal will respond when it auto-answers cails from the host computer.

Entry Process

<empty> Go off-hook, wait 2 seconds, execute Control String in 0038

2 Go off-hook, wait 2 seconds, execute Control String in 0038

1 Go off-hook, wait 2 seconds, raise answer carrier, execute Control String in 0038

0 Go off-hook, wait 2 seconds, raise answer carrier, wait for ENQ, execute Control String in 0038

Memory Location: 0967 Character Type: Numeric Field Length: 1 character

This parameter determines how long the terminal will remain off hook without any communications activity from the host.

Entry Timeout Length

100 seconds 120 seconds

0 Multiple transactions disabled 1 20 seconds

2 40 seconds

3 60 seconds

4 80 seconds

5

6

Page 67 read from a scan by OCR; it may hold reading errors

PIN Pad/ Bar Code Wand Serial Port Function

Line Recovery Time

Free Memory

Reclamation |

Parameter

6. Terminal Parameters

Entry Timeout Length 7 140 seconds

8 160 seconds

9 90 minutes

Memory Location: 0970 Character Type: Numeric Field Length: 1 character

If you wish to use the PIN Pad/Bar Code Wand port, you must specify its function by identifying the device connected to it. Enter the desired number from the table below. If you are not using the port, leave this location empty or enter a "0."

Entry Function

<empty> Nothing Connected

0 Nothing Connected

1 Bar Code Wand

2 PIN Pad

3 General Communications Device

Memory Location: 0975 Character Type: Numeric Field Length: 1 character

When the terminal attempts to dial out and determines that the line is already in use, it will wait until the line becomes available. This parameter determines how long the terminal will remain on hook once the line is available to allow the phone company enough time to disconnect the line and prepare for the next call. Acceptable values for this parameter are in the range of 1 to 255 seconds with a default value of 3 seconds.

Memory Location: 0977 Character Type: Numeric Field Length: 1 character

This parameter controls how memory is made available for re-use once the data in it has been deleted. It is usually empty and should be custom programmed for each application to utilize the various options. If this location is empty, the default is "0": "Reclaim 1 piece of free memory after every store operation."

Entry Description

0 Reclaim 1 piece of free memory after every store operation.

1 Reclaim 1 piece of free memory after each transaction or function. 2 Reclaim all free memory after each transaction or function.

3 Do not reclaim free memory.

Page 68 read from a scan by OCR; it may hold reading errors

Abort Control String

Delay Executing Idle Loop Control String

Idle Loop Control String

Idle Loop Phone Number

Idle Loop

Response Analysis

Control String

TRANZ 380 Reference Manual

Memory Location: 0979 Character Type: Alphanumeric Field Length: 60 characters

This parameter can be used to provide customized processing each time the terminal powers up, or a transaction or local function is completed. This location is usually empty and must be custom programmed for each application to utilize this feature.

Memory Location: 0980 Character Type: Alphanumeric Field Length: Up to 120 characters

This parameter is used in conjunction with the other Idle Loop parameters (0981, 0982, 0983 and 0984). It specifies the time in seconds between each execution of the Idle Loop Control String (0981).

Memory Location: 0981 Character Type: Alphanumeric Field Length: Up to 120 characters

This parameter allows you to program the TRANZ 380 to perform specific tasks while the terminal is in the idle state. It is used in conjunction with the other Idle Loop parameters (0980, 0982, 0983 and 0984).

As an example, the terminal can be programmed to check the current time to see if it has exceeded a predetermined trigger time then automatically dial up a remote host to upload captured records.

Memory Location: 0982 Character Type: Alphanumeric Field Length: Up to 60 characters

This parameter is used in conjunction with the other Idle Loop parameters (0980, 0981, 0983 and 0984). It specifies the phone number to dial for host communications initiated from the Idle Loop Control String (0981).

Memory Location: 0983 Character Type: Alphanumeric Field Length: Up to 120 characters

This parameter is used in conjunction with the other Idle Loop parameters (0980, 0981, 0982 and 0984). It contains the control string used to analyze the response received from a host when the transaction is initiated from the Idle Loop Control String (0981).

Page 69 read from a scan by OCR; it may hold reading errors

Idie Loop Inactivity Timeout

Host for Card Transactions

Host for Bar Code Transactions

Communication Error Control String

VeriFone Control String

6. Terminal Parameters

Memory Location: 0984 Character Type: Alphanumeric Field Length: Up to 60 characters

This parameter is used in conjunction with the other Idle Loop parameters (0980, 0981, 0982 and 0983). It specifies the time in seconds the TRANZ 380 will wait before disconnecting the phone line when performing multiple transactions from the Idle Loop Control String (0981).

Memory Location: 0985 Character Type: Numeric Field Length: 1 character

This parameter specifies which host transaction key control string will be executed when a card is swiped through the reader from the idle state. Valid entries for this parameter are 1 through 9 with the default being 1.

Memory Location: 0986 Character Type: Numeric Field Length: 1 character

This parameter specifies which host transaction key control string will be executed when a bar code is swiped through the reader from the idle state. Valid entries for this parameter are 1 through 9 with the default being 2.

Memory Location: 0990 Character Type: Alphanumeric Field Length: 60 characters

By default, communication errors result in the display of an error message and the termination of the transaction in progress. This parameter is used to allow the TRANZ 380 to customize the processing of communication errors.

This location is usually empty and must be custom programmed for each application to utilize this feature.

Memory Location: 0997 Character Type: Alphanumeric Field Length: 120

This control string is reserved for VeriFone use, specifically, VeriFone testing purposes. A control string may be located here and executed via the TRANZ 380 Diagnostics Menu (see page 8-3).

Page 70 read from a scan by OCR; it may hold reading errors

Programming Error

Recovery Log

Date and Time Transfer

TRANZ 380 Reference Manual

Memory Location: 0999 Character Type: Alphanumeric Field Length: 60

An error condition may occur when the TRANZ 380 is in any of its five modes of operation that requires access to nonvolatile RAM and a checksum error is noted. If you elected to log the programming error event, the result will be in this memory location. See pages 5-11 and 5-12 for more information on programming errors and recovery.

Memory Location: 1000 Character Type: Alphanumeric Field Length: Up to 120

This parameter enables or disables the transfer of the master terminal’s date and time to the slave terminal during a terminal-to-terminal download. A value of "1" enables the transfer of the date and time; a value of "O", or if this location is empty, disables the transfer.