Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 15

TRANZ 380 Reference Manual, pages 51 to 60

Pages 51 to 60 of 148

The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the VeriFone Tranz 380

Page 51 read from a scan by OCR; it may hold reading errors

Resetting the Calendar/Clock

5. Basic Operation

4. When the transaction is completed, the terminal returns to the normal, pre-dial mode.

Post-dialing is only enabled for one transaction at a time. You must press [BACKSPACE/POST] before beginning each transaction that you want post-dialed.

The Calendar/Clock in the TRANZ 380 terminal has a built-in lithium battery to maintain the correct time even when power is removed from the terminal. However, there are occasions when you should reset the clock, such as adjusting for your time zone or resetting the clock to daylight savings time.

To reset the clock, follow these steps: Display

Response

10.

(idle prompt) DIAGNOSTICS

RTC CHIP TEST

YEAR 1980-2079 =

MONTH =

DAY =

HOUR 0-23 =

. MINUTES =

. SECONDS =

(day of week, date and time)

Simultaneously press [*] and [3].

Press [ALPHA] to begin the "reset clock" function.

The terminal will display this message for two seconds while it tests the real time clock (RTC) chip. The terminal will then prompt you through the following entries for reset- ting the date and time.

If you make a mistake, press [BACKSPACE] and reenter the correct information.

Press [FUNC/ENTER] after each entry.

Enter two digits for the current year. For example, enter "91" for the year 1991.

Enter a number, 1 through 12, to identify the current month. For example, enter the num- ber "6" for June.

Enter a number, 1 through 31, to identify the current day. For example, enter "14" for the date June 14. :

Enter a number, 0 through 23, to identify the current hour in a 24-hour format.. For example, enter "10" if the time is 10 a.m.; enter "16" if the time is 4 p.m.

Enter the number of minutes, from 0 to 59, currently past the hour. For example, enter "14" if the time is 10:14.

Enter the number of seconds from 0 to 59, currently past the minute. For example, enter "23" if the time is 10:14 and 23 seconds.

The terminal will display the new date and time.

5-9

Page 52 read from a scan by OCR; it may hold reading errors

Changing the System Password

TRANZ 380 Reference Manual

Certain operations such as STORE and RECALL, require the use of the system password to prevent unauthorized or accidental destruction of data. Each TRANZ 380 is shipped with the factory set system password "Z66831" (press: [1] [ALPHA] [ALPHA] [6] [6] [8] [3] [1]).

You may want to change this password to an unpublished number. You can change the password at any time provided you know what the current password is. The password may contain up to nine alphanumeric characters.

Caution: If you change the system password and then forget or lose the new password, there is no method you can use to determine the new password! Losing or forgetting the new password will prevent you from adding information to memory or changing any of the information already stored in memory! However, transactions that do not require use of the password may still be executed.

The VeriFone Customer Support Department can reset the password back to 266831. This involves shipping the terminal to the VeriFone Customer Support Center and will incur a service charge. See page 8-8 for returning the terminal.

Follow these steps to change the system password.

Display Response 1. (idle prompt) Press [FUNC/ENTER]. 2. FUNCTION? Press [ALPHA].

3. ENTER OLD PASSWD Enter the old password.

Note: Each keystroke is displayed as a "*" (asterisk).

After entering the password, press the [FUNC/ENTER] key.

If the password entered does not match the current system password, the terminal will display the prompt "INVALID PASSWORD":=." Press [FUNC/ENTER] and [ALPHA] to re- Start the procedure and enter the correct password.

If the password entered matches the current system password you will be prompted for the new password.

4. ENTER NEW PASSWD Enter the new password.

Note: Each keystroke is displayed as a "*" (asterisk).

After entering the password, press the [FUNC/ENTER] key.

5. ENT PASSWD AGAIN Enter the new password again.

Page 53 read from a scan by OCR; it may hold reading errors

Terminal Displays PROGRAMING ERR X

Error Codes

Programming Error Override Procedure

5. Basic Operation

Display Response

Note: Each keystroke is displayed as a "*" (asterisk).

After entering the password, press the [FUNC/ENTER] key.

If you incorrectly enter the password, the terminal will abort the change password routine.

if you correctly enter the password both times, the change is successful and the terminal returns to the idle state.

This message indicates that the TRANZ 380 terminal detected an error in its RAM (Random Access Memory). The message will also include a single-digit code (X) to identify the error type.

If this message appears, you must either override the error or remove the error by re-initializing (clearing) the terminal’s memory.

Table 5-3 lists the nine possible codes that may appear at the end of this error message. These codes indicate what the terminal was attempting before the error was detected.

Table 5-3. Programming Error Type Codes

Attempted Operation Start End

Power-up 0 Store from TCL 1 Dial-up download 3 Store from keypad 5 Unit-to-unit download 7 ooh N

CAUTION! Although you can still operate the TRANZ 380 terminal after over-riding the error, the memory is still corrupted. This option is provided only for testing purposes or to allow you to retrieve important data from memory. You must clear the error as soon as possible to ensure reliable operation. To clear the error, download the application program using one of the methods described in Section 3.

Display Response

1. PROGRAMING ERR X Press [5] and [3] simultaneously. Wait for the idle prompt.

2. (idle prompt) « You can now continue with normal operations.

Page 54 read from a scan by OCR; it may hold reading errors

Error Log

Re-initialize Memory Procedure

TRANZ 380 Reference Manual

Display Response

* Use the RECALL procedure described in this section to view any data you might need. The error log is stored in memory location 0999. See Error Log below.

¢« Download the application program as soon as possible. This will re-initialize memory, clearing all remaining errors.

The terminal enters the date, time and type of programming errors in memory location 0999. Entries for up to 12 errors can be stored at one time. A hyphen * separates each entry.

The format for each entry is MMDDYYHHC-, where:

Value Description

MM Month

DD Day

YY Year

HH Hour in 24-hour format

Cc Programming error type code - Entry separator

For example: If location 0999 contains 081291 100-081 291 150-, two errors were detected and overridden after power-up attempts on August 12, 1991 - one at 10 am and the other at 3 pm.

Use the re-initialize memory procedure to clear the error from the terminal. After re-initializing memory, you must download the application program before you can perform any transactions.

CAUTION! Re-initializing memory will clear the application program and data from the terminal. If you need to retrieve any information before clearing these from memory, use the Programming Error Override Procedure instead.

Display Response

1. PROGRAMING ERR X Press [1] and [ENTER] simultaneously. Wait for the idle prompt.

2. (idle prompt) The terminal’s RAM is reinitialized and ready for downloading. Download the application program as described in Section 3.

Page 55 read from a scan by OCR; it may hold reading errors

Terminal Parameters

6.Terminal Parameters

Your TRANZ 380 terminal must be configured with terminal-specific parameters which determine how the terminal operates. Special memory locations are reserved specifically for terminal parameters. By entering the proper

Cation software.

For example, you can determine how many characters the terminal scrolls when the scroll key is pressed, or the phone number of the download computer.

Memory Location Description

0000 Download Phone Number

0001 Serial Number

0004 Program Date

0005 Message Sequence Number

0006 Scroll Length

0007 Multiple Transaction Timeout

0009 Terminal Key Beep Flag

0010 Dial Type Flag

0011 Dial Speed Flag

0012 Parallel Phone Available Flag

0013 Number of Retries

0014 Telephone Line Test Flag

0015 Delay Before Auto Answer

0016 Encrypted Working Key/Master Key Pointer 0017 RECALL, Set Clock, Unit-to-Unit Restriction Flag 0019 Application ID

0030 Idie Prompt

0031-0036 Function Keys (#1-6)

0037 Out of Memory Control String

0038 Auto Answer Control String

Page 56 read from a scan by OCR; it may hold reading errors

Location Parameters

TRANZ 380 Reference Manual

Memory Location

Description

0039 0040-0099 0950 0951 0952 0953 0954 0958 0960 0965 0966 0967 0970 0975 0977 0979 0980 0981 0982 0983 0984 0985 0986 0990 0997 0999 1000

Function Key (#9)

Memory Dial Phone Numbers (Genera! Records) Printer Type

Printer 250 Paper Advance (Number of Line Feeds) Generic Printer Baud Rate

Generic Printer Data Format

Generic Printer Handshake

Bell/CCITT Mode

Dial-Up Line Upload/Download Speed

Auto Answer Speed

Auto Answer Processing

Auto Answer Packet Inactivity Timeout

PIN Pad/Bar Code Wand Serial Port Function Line Recovery Time

Free Memory Reclamation Parameter

Abort Control String

Delay Executing Idle Loop Control String

Idle Loop Control String

Idle Loop Phone Number

Idle Loop Response Analysis Control String Idle Loop Inactivity Timeout

Host # for Card Initiated Transactions

Host # for Bar Code Initiated Transactions Communication Error Control String VeriFone Control String

Programming Error Recovery Log

Date and Time Transfer

Entering Terminal/ _ {f you are using a standard application or if you programmed your terminal by downloading an application from another TRANZ 380 terminal, you must configure your terminal with the Terminal/Location parameters.

Use the STORE or RECALL functions as described in Section 5 for instructions on entering information into your terminal’s memory locations.

Note: If you programmed your terminal with a remote IBM PC compatible download computer, these parameters may have already been entered for you. Use the RECALL function to determine if the parameters were downloaded.

Download Memory Location: 0000 Phone Number Character Type: Alphanumeric Field Length: Up to 32 characters

This parameter is the phone number the terminal dials to connect to the remote download computer. The download phone number may contain up to 32 characters including numerals 0 through 9 and a two-second pause (-).

Page 57 read from a scan by OCR; it may hold reading errors

Serial Number

Program Date

Message Sequence Number

6. Terminal Parameters

You can enter an access code with the phone number and, if needed, separate the two by inserting the pause character between them. For example, if you enter the common outside line access code "9" followed by a dash (-) and the phone number, the terminal will dial the 9, pause two seconds, then continue dialing the phone number. Insert additional pause characters as needed for pauses longer than two seconds.

If the memory location is empty, the terminal will automatically prompt you for the download data.

Note: Do not add a dash (-) in the middle of a phone number. This will create an unnecessary delay in dialing the number. The pause character is intended for deliberate pauses between access codes and phone numbers.

Memory Location: 0001 Character Type: Alphanumeric Field Length: Up to 10 characters

Turn your terminal upside down and locate the serial number on the label after the characters "S/N." Enter this number into memory location 0001. This number identifies your terminal to the download computer.

If the memory location is empty, the terminal will automatically prompt you for the download data.

Memory Location: 0004 Character Type: Numeric Field Length: 6 characters

Enter the date into memory location 0004. This records the date that the parameters in the terminal were updated.

The format for this parameter is MMDDYY. For example, to enter July 23, 1991, enter "072391."

Format Description

MM Month DD Date YY Year

Memory Location: 0005 Character Type: Numeric Field Length: 4 characters

The TRANZ 380 terminal assigns a sequence number to every VISA second generation transaction it performs.

The terminal sequentially numbers each transaction, thus identifying the order in which the transactions are performed.

The message sequence number (also called the transaction sequence number) parameter allows you to specify the number of the first transaction in the

6-3

Page 58 read from a scan by OCR; it may hold reading errors

Scroll Length

Multiple Transaction

Timeout

Terminal Key Beep Flag

TRANZ 380 Reference Manual sequence. For example, if you select the number 0500, the first transaction will be numbered 0500, the second 0501, the third 0502 and so on.

Memory Location: 0006 Character Type: Numeric Field Length: Up to 2 characters

The TRANZ 380 terminal has a 16 character display panel which is adequate for viewing most prompts. To view messages longer than 16 characters, you will need to scroll to the right or to the left. The scroll length parameter determines the number of characters that will be scrolled each time the right [*] or left [#] scroll keys are pressed. For example, if the parameter selected is "12," pressing the [*] key will scroll the display 12 characters to the right.

Memory Location: 0007 Character Type: Numeric Field Length: 1 character

The multiple transactions feature of the TRANZ 380 allows the terminal to perform more than one transaction on a single call to a host computer. This parameter specifies the length of time the terminal will wait between transactions before disconnecting the phone line.

If a transaction ends and a new one doesn't begin within the time specified in this parameter, the terminal will break the phone connection with the host computer. However, as long as another transaction begins within the specified time, the terminal will remain connected.

Ten different entries are available. If nothing is entered in the memory location, the multiple transaction feature is disabled.

Entry Timeout Length

Multiple transactions disabled 20 seconds

40 seconds

60 seconds

80 seconds

100 seconds

120 seconds

140 seconds

160 seconds

90 minutes

COON DUAR WN$O

Memory Location: 0009 Character Type: Numeric Field Length: 1 character

The terminal key beep flag indicates whether or not the terminal should beep when the keys are pressed. Enter a 0 if you want a beep, or enter a 1 if you don’t want a beep.

Page 59 read from a scan by OCR; it may hold reading errors

Dial Type Flag

Dial Speed Flag

6. Terminal Parameters

Memory Location: 0010 Character Type: Numeric Field Length: 1 character

This parameter indicates the type of dialing your TRANZ 380 terminal will use, whether tone or pulse, and also allows enhanced pulse dialing setting for Europe.

Entry Description fe) Tone dial

1 Pulse dial (USA) 2 10 - ndial

3 n+ 1 dial

Note: The terminal must be configured for the type of telephone transmission used by the telephone company central office in your area. Check with your phone company if you do not know which type of service you have.

Parameters 2 and 3 contain pulse dialing settings where "n" represents the telephone number digit you dial. If you dial the digit "0" with a parameter 2 setting, there will be 10 pulses. If you dial a "1", there will be 9 pulses. Parameter 3 is just the opposite, with the digit "0" having 1 pulse and the digit "9" having 10 pulses.

Memory Location: 0011 Character Type: Numeric Field Length: 1 character

The TRANZ 380 terminal can be programmed to dial a phone number at one of five speeds. This parameter determines the number of digits or pulses per second. If nothing is entered for the parameter, the terminal will dial a normal 10 digits per second or 10 pulses per second.

Entry Speed

5 per second; very slow dial 7 per second; slow dial

10 per second; normal dial 15 per second; fast dial

20 per second; very fast dial kONnM+-oO

Note: The Canadian Department of Communications (DOC) does not permit dialing speeds greater than 10 digits or pulses per second to be used in Canada.

Page 60 read from a scan by OCR; it may hold reading errors

Parallel Phone Available Flag

Number of Retries

Telephone Line Test

TRANZ 380 Reference Manual

Memory Location: 0012 Character Type: Numeric Field Length: 1 character

This parameter indicates if a standard telephone is connected to the same telephone line as the TRANZ 380 terminal. This flag permits the automatic dialing of the call center of the "PICK-UP CARD" phone number provided the host computer sends a RealShare or VISA second generation type message with an autodial command.

Enter a "0" if a phone is not connected. Enter a "1" if a phone is connected.

Note: The TRANZ 380 terminal beeps when either of the automatic phone numbers is dialed, indicating that the clerk should pick up the handset for instructions.

Memory Location: 0013 Character Type: Numeric Field Length: 1 character

You can select the number of times the TRANZ 380 terminal will redial a telephone number for a transaction before giving up. For example, if a "5" is entered, the terminal will dial the primary phone number up to five times followed by the secondary phone number five times. The terminal won't stop dialing until the other phone is answered or if the number of attempts indicated here are made. If no entry is made for this memory location, the terminal will default to three attempts.

Memory Location: 0014 Character Type: Numeric Field Length: 1 character

This parameter tests the telephone line to determine if another telephone is being used on the same line. If the test is activated and a phone is being used, the terminal will not perform the transaction until the line is free.

The line test also enables the TRANZ 380 terminal to interact with the control ° Signals of standard key telephone systems. In a key system, the A/A1 wires on a telephone line indicate when a call is on hold. To work ona key system, the TRANZ 380 must enable A/A1 control.

Note: A/A1 activation support is available only as a special order option. If you require this support, please call your VeriFone sales representative.

There are four options for this parameter. Entry Description

0 Activate A/At, do line test.

1 Activate A/A1, don’t do line test.

2 Don't activate A/A1, do line test.

3 Don’t activate A/A1, don't do line test.