The text of a manual · part 4 of 15
TRANZ 380 Reference Manual, pages 31 to 40
Pages 31 to 40 of 148
The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the VeriFone Tranz 380
Page 31
Performing the Direct PC Download
3. Downloading logo@
Connect this end to the 5
8-pin DIN connector ’
(printer port) y a
Connect this end to the PC's COM1 or COM2 serial port
Figure 3-3. TRANZ 380 to PC Connection
Following the instructions in the ZONTALK 2000 Reference Manual, set up ZONTALK 2000 on your PC to perform a direct download: then perform the following steps on the TRANZ 380 terminal. Ensure that the PC is properly connected to the TRANZ 380 terminal before downloading.
Display
Response
1. (idle prompt)
2. FUNCTION?
4. DOWNLOAD DONE
5. (idle prompt)
On the TRANZ 380 terminal, press [FUNC/ENTER].
Press [#] to indicate you want to receive a direct download.
The PC will now download the program to the terminal. A simple graphic is displayed on the terminal showing the progress of the download. As the download progresses, the graphic changes to show the percentage of the download complete - with each character representing 10% of the download.
This prompt indicates a successful download. if you see the prompt DOWNLOAD FAILED: * Reset the PC for another download.
* Press any key on the TRANZ 380 terminal to return to the FUNCTION? prompt.
* Repeat step 2 above. If the download fails again, you may be trying to down- load an invalid or nonexistent program.
Press [CLEAR].
The terminal will automatically restart and begin running the application program.
Page 32
TRANZ 380 Reference Manual
Note: If you wish to download the application to additional terminals, connect the next TRANZ 380 terminal to the PC and repeat steps 1 through 4. Repeat this operation for each terminal that requires the application program.
Telephone Download _ if you do not have a PC running ZONTALK 2000, version 2.0 or higher, at your location, you will have to call a remote download computer to request a download. Many TRANZ 380 terminals in the field receive application code and parameter data via telephone download.
With telephone downloading, you can choose either a full or partial download. A full downtoad sends all application code and parameter data. A partial download sends only the data needed to upgrade the application or parameters already in a terminal. This is faster than completely replacing all of this information in your terminal. The contents of a partial download are determined by the ZONTALK 2000 software. However, if the terminal does not have any application code, or if you are not sure if it does, request the full download.
When telephone downloading, the TRANZ 380 terminal prompts you for the correct data if nothing is programmed in the following memory locations.
Memory Location Information
0000 Download computer's telephone number.
0001 TRANZ 380 terminal serial number. This number is located on the bottom of the terminal.
0019 Application ID number. Obtain this number from the person responsible for maintaining the application files in the download computer.
0960 Speed selection. This memory location should contain a "2" for 1200 baud communication or a "1" for 300 baud communication. The speed selected must match the speed used by the download computer.
Download Prompts for The procedure for entering any of the above locations during a download is Empty Memory Locations _as follows:
Display Response
1. (idle prompt) Press [FUNC/ENTER]
2. FUNCTION? Press [0].
3. DOWNLOAD? Press [FUNC/ENTER]
4. DWNLD PHONE NUM? The TRANZ 380 will prompt you if any of the SERIAL NUM? four memory locations is empty. Enter the APPLICATION ID? phone number, serial number, application ID DNLD SPEED? and download speed as necessary.
Continue with Step 4 on page 3-7.
Page 33
Telephone Download Procedure
3. Downloading
Display
Response
1. (idle prompt) 2. FUNCTION? 3. DOWNLOAD?
4. DIALING
5. WAITING FOR ANSR
Press [FUNC/ENTER]. Press [0].
* If you want a complete download of appli- cation code and parameter data, press [FUNC/ENTER].
*, If you want a partial download, press [*).
Wait, the terminal is dialing the download computer.
If the terminal displays WAITING FOR LINE, check the telephone line cord connection. If the cord is properly connected, the line may be busy. Press [CLEAR] to abandon the call, or wait until the line is free.
The terminal is waiting for the download computer to answer.
The PC will now download the data to the terminal. A simple graphic is displayed on the terminal showing the progress of the download. As the download progresses, the graphic changes to show the percentage of the download complete, with each charac- ter representing 10% of the download.
Note: If the remote download computer can- not locate your application's id number in its data base, the prompt APPL ID NOT FND will be displayed. Press [CLEAR] to cancel the download, check memory location 0019 and try again. If the problem persists, con- tact the person responsible for maintaining the download computer.
Note: If the remote download computer can- not locate your terminal's serial number in its data base, the prompt SERIAL # NOT FND will be displayed. Press [CLEAR] to cancel the download, check memory location 0001 and try again. If the problem persists, con- tact the person responsible for maintaining the download computer.
Page 34
BuyPass Download
TRANZ 380 Reference Manual
Display
Response
7. DOWNLOAD DONE
The terminal successfully completed the download. Press [CLEAR] to return to the idle prompt.
lf UNSUCCESSFUL DL appears instead, the terminal was unable to complete the down- load. This could be due to bad telephone lines or other problems not related to the terminal.
Press [CLEAR] and try the download proce- dure again. If the problem persists, contact the VeriFone Customer Hot Line.
TRANZ 380 terminals support BuyPass downloads, which allow for a set of keystrokes other than what is used in ZONTALK 2000, version 2.0 or higher. To access this feature, follow the instructions below:
Display
Response
1. (idle prompt) 2. DOWNLOAD?
3. DWNLD PHONE NUM? 4. MERCHANT ID?
5. DIALING WAITING FOR ANSWER COMMUNICATING DOWNLOAD DONE
Press [FUNC] and [0].
Press either [1] or [2]. {1] = full download [2] = partial download
Enter the download phone number. Enter the merchant ID number.
Wait until the download is done.
Page 35
Host Transactions
4. How the TRANZ 380 Works
This section will give you an overview of the TRANZ 380 Capabilities and how its different functions work. More detailed operational information can be found in your application manual.
The TRANZ 380 operates as a basic transaction computer with pre-programmed prompts for banking applications. It is intended to communicate with a host computer, which is typically located at a financial institution or a company's data processing center. Host computers can store and process large amounts of data, including a customer's account history. By communicating with the host computer, usually over telephone lines, the TRANZ 380 puts this vast data base at the terminal operator’s fingertips. The host computer notifies the terminal operator whether or not a transaction can be authorized.
The TRANZ 380 terminal can be programmed to perform up to nine different transactions with remote host computers. The specific transactions available are determined by the application program downloaded to the terminal.
A typical host transaction involves dialing the host computer, providing the host computer with information about the terminal and the customer, and receiving authorization to complete the transaction.
One transaction key is reserved for each type of transaction used by each host computer. For example, if you use three different transactions for each of three different host computers, you will need all nine transaction keys.
CLEAR
QZ.} }ABC} | DEF
: GHI, ] JKL MNO BACK S| 4 5 6 SPACE : PRSE4TUV WXY] ALPHA 7 Ff : 8 9 RECALL STORE ; au . SP # FUNC ds 0 [>| ENTER
AUTO
Figure 4-1. TRANZ 380 Host Keys
Page 36
Local Functions
Applications
Standard Application
Custom Applications
TRANZ 380 Reference Manual
Unlike host computer transactions, local functions are performed only at the terminal and do not require communications with a host computer. in fact, most local functions can be performed, even when the phone line is discon-nected or busy.
The TRANZ 380 can perform several different local functions. Some of these functions are standard for all terminals. Up to seven custom local functions (also called local transactions) can be programmed for your application and performed from the keypad. However, the actual number of local functions available to the user depends on how many were programmed into the application.
The local functions available vary with each application. However, some typical local functions may include the following. Refer to your application reference manual for information on the local functions available to you.
* Calculating batch totals;
* Storing user identification information;
*, Listing different transactions previously stored in the terminal: * Date and time calculation; and
* Printing transaction data or other information.
The way a TRANZ 380 terminal operates and the procedures it follows is determined by its application (also called application program). An application is a series of instructions electronically stored (programmed) in the terminal's memory. These instructions direct the terminal to perform specific operations and to respond properly to different events as they occur.
Each TRANZ 380 terminal is supplied with the same standard application. However, to meet the specialized needs of a company, many terminals are programmed with a custom application.
Although each TRANZ 380 is initially programmed with a standard application, this application is only accessible on terminals that do not have a custom application already loaded into them. The standard application allows the user to access many of the services offered by several host computers. This is often sufficient for handling the needs of many companies. However, because the standard application may not meet all of the specialized needs of some companies, many TRANZ 380 terminals are programmed with a custom application.
Custom applications help make the terminal work within a company’s existing operations rather than forcing a company to change transaction procedures to work with a terminal.
These applications can specify how host computer transactions will be performed and how extensive security and fraud control measures will be. If other devices, such as a printer, are used with the terminal, a custom application can precisely determine the procedures and formats for entering and printing information with these devices.
Page 37
Programming a Custom Application
4. How the TRANZ 380 Works
Custom applications are created by programmers using the VeriFone Terminal Control Language (TCL). TCL programming is typically performed on an IBM PC or compatible computer. When the application is completed, it can be sent from the computer to the terminal using a process called downloading. The downloading process transfers the application to the terminal and stores it electronically in the terminal’s memory. See Section 3 for downloading information.
With the inception of the TRANZ 380, there are now two different types of memory available for creating custom TCL applications: Program and Batch. Program Memory holds the TCL application itself and Batch Memory holds batch files. A batch file is a group of input data that is collected together and processed as a single unit. The terminal stores batch files in RAM. As more transactions are performed, the terminal typically adds input data to the open batch until the batch is closed or the memory becomes full.
Program Memory may be up to 64K, while Batch Memory can grow to use all available RAM. For both types of memory, the system memory of the terminal must also be considered when caiculating free space. The formula for determining Program Memory space is: Total RAM (64K or 128K) less System Memory less Batch Memory = Program Memory.
The formula for determining Batch Memory space is: Total RAM (64K or 128K) less System Memory less Program Memory = Batch Memory. Again, Program Memory is limited to 64K, but Batch Memory can take up all available RAM not being used by System Memory and Program Memory.
Figure 4-2 illustrates Program and Batch Memory for the 64K and 128K versions of the TRANZ 380. Due to the differences between Batch and Program Memory, the *S and *Z TCL commands have changed (see Appendix D).
Program Memory
|
Program Memory, contains TCL application
64K Terminal
64K, _- / pach \” Program and Batch Memory Batch Memory
128K Batch 7 1 Memory 128K Program Program Memory, t Program Memory, contains TCL Memory, 64K contains TCL application. contains TCL application. Cannot application Cannot exceed 64K. System exceed 64K. System System I \__ System) 128K Terminal 64K Terminal 128K Terminal
Programming with the Keypad
Figure 4-2. Program and Batch Memory
The TRANZ 380 keypad can be used to quickly modify part of an application Program or to update some of the data stored in the terminal's memory (such as a host computer telephone number). However, creating an entire application is always done on personal computers. These computers have more memory and more keys which make them better equipped for typing and editing application code.
Page 38
RAM and ROM Memory
Memory Locations
Terminal Parameters
TRANZ 380 Reference Manual
Application code, parameter data and system firmware (code permanently programmed into the terminal at the factory) all reside in the terminal's electronic memory. There are two different types of electronic memory in each TRANZ 380 terminal - Random Access Memory and Read Only Memory. Random Access Memory, or RAM, is used to store information that can be easily acquired and modified. Because this memory is readily changed, it is useful for storing custom applications, temporary data entered from the keypad or card reader, phone numbers, the date and time, and other information that may be subject to change from time to time.
Because RAN is also temporary, the built-in battery provides backup power to preserve data in RAM in the event of a power failure.
Read Only Memory, or ROM, is factory installed with each TRANZ 380 terminal. This information is permanent and cannot be changed by the user or application programmer. Because it cannot be changed, ROM is ideal for Safely storing the operating system firmware which controls the different components of the terminal and allows the downloading and use of custom applications. The standard application found in all TRANZ 380 terminals is also stored in ROM.
RAM memory is divided into segments called memory locations. Some memory locations are dedicated to specific functions. For example, memory location 0001 is reserved for the terminal's serial number and location 0004 is reserved for the current date. Other memory locations are general purpose locations which can be used for a variety of functions.
Because RAM memory locations are temporary, the information they contain can be changed at any time. However, for security reasons, these locations can be password protected to prevent unauthorized tampering.
Caution: Do not alter the information in TRANZ 380 memory locations unless you fully understand what you are changing. Your terminal will not be able to function properly unless the locations contain valid data.
Note: While the reserved memory locations are accessible, we recommend that you not use them. Using these memory locations now may cause conflicts in the future with subsequent firmware versions.
A terminal parameter is information that relates to the terminal itself. Table 4-1 lists the different parameters that may be used by your application. However, the actual parameters used depends on the application programmed in your terminal. Each parameter is explained in more detail in Section 6, and all memory locations are listed in Appendix A.
Table 4-1. Terminal Parameters
Memory Location Parameter
0000 Remote Download Computer Phone Number 0001 Terminal Serial Number
0004 Program Date
0005 Message Sequence Number
0006 Scroll Length
Page 39
4. How the TRANZ 380 Works
Memory Location Parameter
0007 Multiple Transaction Timeout 0009 Terminal Key Beep
0010 Dial Type
0011 Dial Speed Flag
0012 Parallel Phone Available Fiag 0013 Number of Attempts
0014 Telephone Line Test
0015 Delay Before Auto Answer 0017 RECALL, Set Clock, Unit-to-Unit Restriction Flag 0019 Application ID
0030 Idle Prompt
0031-0036 Function Keys #1-6
0037 Out of Memory Control String 0038 Auto Answer Control String 0039 Function Key #9
0040-0099 Memory Dial Phone Numbers (General Records) 0950 Printer Type
0951 Printer 250 Paper Advance (Number of Line Feeds) 0952 Generic Printer Baud Rate
0953 Generic Printer Data Format
0954 Generic Printer Handshake
0958 Bell/CCITT Mode
0960 Dial-Up Line Upload/Download Speed 0965 Auto Answer Speed
0966 Auto Answer Processing
0967 Auto Answer Packet Inactivity Timeout 0970 PIN Pad/Bar Code Wand Serial Port Function 0975 Line Recovery Time
0977 Free Memory Reclamation Parameter 0979 Abort Control String
0980 Delay Executing Idle Loop Control String 0981 Idle Loop Control String
0982 Idle Loop Phone Number
0983 Idle Loop Response Analysis Control String 0984 Idle Loop Inactivity Timeout
0985 Host # for Card Initiated Transactions 0986 Host # for Bar Code Initiated Transactions 0990 Communication Error Control String
0999 Programming Error Recovery Log
0955 - 0957
0959
0961 - 0964
0968 - 0969
0971 - 0974 Reserved
0976
0978
0987 - 0989
0991 - 0996
Page 40
Transaction Parameters
Multiple Transactions
Networks
TRANZ 380 Reference Manual
Memory Location Parameter
0998 > 1000 - 1049 Reserved
Each transaction requires a set of parameters before the transaction can be performed on a TRANZ 380 terminal. For example, the host computer phone number must be stored in the correct memory location before the terminal can dial the host computer.
Once the necessary parameters are stored, the terminal will automatically execute the transaction when the associated transaction key is pressed.
Because the TRANZ 380 can accommodate up to nine different transactions, memory locations are reserved for nine different sets of parameters.
Table 4-2 lists the different parameters that may be required for a transaction with a host computer. However, the actual parameters used depends on the requirements of a particular transaction.
Table 4-2. Transaction Parameters
Memory
Location Parameter (X = transaction keys 1-9) 0X00 Primary Phone Number
0x01 Secondary Phone Number
0x02 Cail Center Phone Number
0X03 Referral Card Phone Number 0X04 Merchant/Terminal ID
0X05 Message Format Flag
0X06 Fraud Control Fiag
0X07 Transaction Control String
0X08 Transaction Type Prompt
0X09 Floor Limit
0X10 Response Analysis Control String OX11 Auxiliary Control String
0X12 Multiple-Transaction Group Code 0020-0029 Login Strings 0 through 9
Note: Each of the nine transaction keys has its own set of parameters. For example, the merchant ID memory location for transaction key "2" is 0204. For key "3," the merchant ID memory location is 0304.
TRANZ 380 can perform multiple transactions on a single dial up. Multiple transactions are performed back-to-back; when one transaction is finished, the operator starts the next one until all transactions are completed. This feature, when supported by the host computer, speeds up transactions by reducing the number of times the terminal dials up the host computer. TRANZ 380 permits communications with several separate networks. Networks help callers reach a remote computer that cannot be easily accessed by direct telephone connection. The network receives a call from the terminal and routes the call to the desired host computer.