The text of a manual · part 3 of 15
TRANZ 380 Reference Manual, pages 21 to 30
Pages 21 to 30 of 148
The original document is the PDF (5.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the VeriFone Tranz 380
Page 21
Connecting the Printer 250 (optional)
| ©
2. Installation
Warning: Before installing the Printer 150, be sure the TRANZ 380 terminal is not plugged into a power source.
1. Connect the small plug from the printer power pack to the power connector of the Printer 150, located on the right side of the rear panel. Ensure that the flat surface is up (arrow facing forward).
2. Plug the printer interface cable into the 8-pin mini-DIN connector on the rear of the printer.
3. Plug the other end of the cable into the TRANZ 380's RS-232 port.
Plug the male AC power cord plug into an indoor, grounded 120 volt AC outlet. Verify that the green POWER indicator comes on. Do not install or operate the Printer 150 outdoors.
Note: If you are running the Printer 150 in the Printer 100 emulation mode, press the RESET button on the Printer 150 after you power up your terminal. This will help ensure correct operation with your terminal’s application software.
Note: Figure 2-3 depicts power pack with part number 02396-01. If power pack with part number 10890-01 is used, the power cord will appear from the opposite side of the power pack; however, this does not effect the connections. Ensure that the flat surface of the small plug is
RS-232 port oo 3 up (arrow facing y forward)
a,
Printer Power Pack mini-DIN connector
|
Printer Interface Cable
Figure 2-3. Printer 150 Connections
The VeriFone Printer 250 is a low-cost, high-performance roll printer. It prints receipts and local reports on rolls of continuous plain or 2-ply carbon-less roll paper at up to 42 characters per line. The Printer 250 combines the versatility of a dot matrix printer with a small footprint and a wide range of features to satisfy the printing needs of transaction processing operations.
The following instructions are for connecting the Printer 250 to the TRANZ 380. Follow the instructions supplied with the printer for unpacking, inserting paper and ink ribbons and maintenance. Use VeriFone printer interface cable with part number 10448-XX (straight connector) or 10454-XX (90-degree connector).
Page 22
Connecting the Printer 500 (optional)
TRANZ 380 Reference Manual
Warning: Before installing the Printer 250, be sure the TRANZ 380 terminal is not plugged into a power source.
1. Connect the 4-pin mini-DIN plug from the printer power pack to the power connector of the Printer 250, located on the right side of the rear panel.
2. Plug the printer power pack into an indoor, grounded 120 volt AC outlet. Do not install or operate the Printer 250 outdoors.
3. Plug the 8-pin mini-DIN connector of the printer interface cable into the communications port of the Printer 250, located on the left side of the rear panel.
4. Connect the other end of the printer interface cable to the TRANZ 380’s RS-232 or printer port, located on the right side of the rear panel.
Plug power pack only into an indoor, grounded AC outlet.
Mini-DIN Mini-DIN us Plug Plug
Printer interface Cable, - - ____ Printer Power
Pack
Figure 2-4. Printer 250 Connections
The VeriFone Printer 500 is a high-performance, dot-matrix printer that prints up to 42 characters per line. It has several paper feed options and can print on precut paper slips, continuous paper rolls, or both.
The following instructions are for connecting the Printer 500 to the TRANZ 380. Follow the instructions supplied with the printer for unpacking, inserting paper and ink ribbons and maintenance. Use VeriFone printer interface cable with part number 10448-XX (straight connector) or 10454-XX (90-degree connector).
Warning: Before installing the Printer 500, be sure the TRANZ 380 terminal is not plugged into a power source.
1. Insert the 3-pin mini-DIN plug from the printer power pack into the power connector on the left side of the Printer 500 rear panel. Note: This is a self-locking plug. When you wish to remove the cable, you must first pull the outer sleeve on the plug straight back.
2. Many Printer 500 power packs have a permanently attached AC power cord. However, if your power pack has a separate removable AC power cord, plug the cord into the connector on the power pack.
3. Insert the 8-pin mini-DIN plug of the printer interface cable into the RS-232 connector of the Printer 500, located on the right side of the rear panel.
Page 23
2. Installation
4. Connect the other end of the printer interface cable to the TRANZ 380's RS-232 or printer port, located on the right side of the rear panel.
5. Plug the male AC power cord plug into an indoor, grounded 120 volt AC outlet. Do not install or operate the Printer 500 outdoors.
Printer f \. RS-232 Port
Power
\ Se
SLUG LS ben DQ Mini-DIN 4 3-pin | SS Plug t Mini-DIN Plug . .
Printer Interface Cable”
Figure 2-5. Printer 500 Connections
Connecting the The VeriFone Printer 600 is a quiet and very economical thermal roll printer Printer 600 __ that prints up to 40 characters per line, or 80 compressed characters. Its (optional) smail footprint and ability to mount to a wall makes it ideal for many locations.
The following instructions are for connecting the Printer 600 to the TRANZ 380. Follow the instructions supplied with the printer for unpacking, inserting paper and maintenance. Use VeriFone printer interface cable with part number 10448-XxX (straight connector) or 10454-Xx (90-degree connector).
Warning: Before installing the Printer 600, be sure the TRANZ 380 terminal is not plugged into a power source.
1. Insert the 8-pin mini-DIN plug of the printer interface cable into the RS-232 connector of the Printer 600, located on the left side of the rear panel.
2. Connect the other end of the printer interface cable to the TRANZ 380’s RS-232 or printer port, located on the right side of the rear panel.
3. Attach the small plug on the power pack cord to the power pin of the Printer 600, located on the right side of the rear panel.
4. Plug the two-prong AC connector from the power pack into an indoor 120 volt AC outlet. Do not install or operate the Printer 600 outdoors.
Mini-DIN ( , Plug
Figure 2-6. Printer 600 Connections
RS-232 Ports
Printer Interface Cable
Page 24
TRANZ 380 Reference Manual
Connecting the, Connect the plug on the bar code wand to the PIN Pad/Bar Code port on the Bar Code Wand rear of the TRANZ 380 terminal, as shown below in Figure 2-7. (optional) Warning: Before connecting the bar code wand, be sure the TRANZ 380 terminal is not plugged into a power source.
PIN Pad/Bar Code Port i
Figure 2-7. Bar Code Wand Connection
Connecting The TRANZ 380 terminal can be used with either the PINPad 101 (hand-held the PIN Pad model; Figure 2-8, left frame) or the PINPad 201 (terminal-size model; Figure (Optional) 2-8, right frame). The following steps are typical for connecting either PIN pad:
Warning: Before connecting a PIN pad to the TRANZ 380, be sure the terminal is not plugged into a power source.
1. Connect the modular plug on the PIN pad cable to the modular jack on the rear of the PIN pad.
2. Connect the 6-pin DIN plug on the other end of the cord to the PIN Pad/ Bar Code port on the rear of the TRANZ 380 terminal.
TRANZ 380 PINPad 101
PINPad 201 TRANZ 380
~~, A - Modular Plug Be sure to install grommet flush to , VT be Gos. rear of PIN pad as shown here \. ° -* “ Pot
Figure 2-8. PIN Pad Connections
Page 25
Connecting the Terminal Power Pack
Routing Cords in the Cable Channels (optional)
2. Installation
1. Attach the small plug on the power pack cord to the power pin on the rear of the terminal.
2. Plug the two-prong AC connector from the power pack into an indoor 120 volt AC outlet.
Warning: Do not plug the power pack into an outdoor outlet or operate the TRANZ 380 terminal outdoors. Disconnecting the power source during processing may cause program corruption and/or loss of data capture files.
Connect power pack IN to indoor 120 volt AC ly. Power Pin outlet only pF) @)
Figure 2-9. Power Pack Connections
The cable routing channels, located underneath the terminal, allow you to hang the power and modular line cords from the front of the terminal instead of the rear.
1. Turn the TRANZ 380 terminal upside down and locate the cable channels. (See Figure 2-10.)
2. Insert a section of each cable into the channel closest to the cable plug. Be sure that the cords are straight and nested securely in the channels.
3. Turn the terminal right side up and place it back in its Original position with the cords neatly out of the way.
Insert cords in these channels.
I | | is a9 lei Fok)
Figure 2-10. Cable Routing Channels
]
Page 26
TRANZ 380 Reference Manual
Page 27
TRANZ 380 Downloading
Terminal-to-Terminal Direct Download
3. Downloading
Before you can fully operate the TRANZ 380, its memory must contain both application code and parameter data. Application code provides the instructions the terminal needs to perform its operations and to respond to different events as they occur.
Parameter data is additional information specific to a terminal, host computer or merchant. Examples of parameter data include the terminal serial number, host computer phone number and the merchant identification number. Because application code is usually lengthy, it should rarely be entered from the terminal's keypad. Instead, applications are transferred from a download computer or another terminal. Parameter data can be entered from the keypad, or it can be easily downloaded like application code.
There are three different ways to download the application code: *, Terminal-to-Terminal Direct Download
* Direct PC Download
* Telephone Download
Note: TRANZ 330 Track 2 applications should run on the TRANZ 380 without modification. TRANZ 330 Track 1 applications, as well as Track 1 and Track 2 applications, will require a few modifications.
This is the simplest download method. Terminal-to-terminal downloads involve copying all the information from the memory of one terminal : (master) into the memory of another terminal ~ Master Terminal (slave). This results in two terminals with exactly the same information in each memory location.
Before using this download method, you must have a "master" terminal with all of the application code and parameter data already stored in its memory. Use telephone or direct PC down- loading if you need to create a master terminal. The following instructions describe how to per-
Slave Terminal form a terminal-to-terminal download. You will Figure 3-1. . need a download cable (VeriFone part number Terminal-to-Terminal 00490-00) for this procedure. Download
The following table illustrates which terminal-to-terminal downloads are possible and which are not.
Page 28
Master/Slave Considerations
TRANZ 380 Reference Manual
Table 3-1. Terminal-to-Terminal Downloading Possibilities
Master Slave Possible?
TRANZ 380 w/64K RAM TRANZ 380 w/64K RAM Yes TRANZ 380 w/128K RAM TRANZ 380 w/128K RAM Yes TRANZ 380 w/64K RAM TRANZ 380 w/128K RAM Yes TRANZ 380 w/128K RAM TRANZ 380 w/64K RAM No TRANZ 380 (any) TRANZ 330 (any) No TRANZ 330 (any) TRANZ 380 (any) No
The TRANZ 380 sending the information is called the master terminal; the TRANZ 380 receiving the information is called the slave terminal.
Terminal-to-terminal downloads completely replace the memory in the slave terminal. You must manually enter the data in those memory locations specific to an individual terminal.
For example, memory location 0001 is reserved for a terminal’s serial number. if the number is not changed, this memory location will contain the serial number of the master terminal instead of the slave terminal.
Usually only the terminal’s serial number will have to be changed. However, refer to your application reference manual to see if any other memory locations are affected by the download. Use the STORE or RECALL functions as described in Section 5 to change individual memory locations.
During terminal-to-terminal downloads, the date and time of the master terminal can be transferred to the slave terminal. Since this feature is not always de-sirable, you have the option of enabling or disabling it. By changing memory location 1000 to "1", this feature is enabled; by changing it to "0" or leaving it empty, this feature is disabled. See Section 6 for more information.
1. Connect one end of the terminal-to-terminal download cable to the 8-pin DIN connector (printer port) on the back of the master terminal.
2. Connect the other end of the cable to the 8-pin DIN connector on the back of the slave terminal.
8-pin DIN Connector
VL. ~
Figure 3-2. Terminal-to-Terminal Connections
3. Use the terminal's displayed prompts as a guide for the following procedure to download the application code and parameter data.
Page 29
On the Master Terminal:
On the Slave Terminal:
3. Downloading
Display
Response
1. 2.
@
(idle prompt) FUNCTION?
ENTER PASSWORD?
UNIT SEND
(idle prompt) FUNCTION?
On the master terminal, press [FUNC/ENTER].
Press [*] on the master terminal.
Note: If memory location 0017 contains a non-zero number, the memory will be password protected. You will be required to enter the system password before proceeding with the download. This is a feature designed to pre- vent unauthorized access to the data stored in the terminal.
If memory location 0017 contains a zero, the password is not required and you can proceed to step 5.
Enter the system password to unlock memory information. The system password supplied with each terminal is 266831 (press: [1] [ALPHA] [ALPHA] [6] [6] [8] [3] {1]). How- ever, if you or the application programmer have already created a new password, enter the new password instead.
The terminal will display an asterisk for each key entered.After entering the complete password, press [FUNC/ENTER].
The display panel will show UNIT SEND to indicate that the master terminal is ready to download to the slave terminal.
Press the slave terminal [FUNC/ENTER] key.
Press [#}] on the slave terminal. The slave terminal will momentarily display UNIT RECEIVE indicating that it is ready to receive the information from the master terminal.
Note: If memory location 0017 contains a non- Zero number, the memory will be password protected. You will be required to enter the system password before proceeding with the download. This is a feature designed to pre- vent unauthorized access to the data stored in the terminal.
lf memory location 0017 contains a zero, the Password is not required and you can proceed to step 10.
Page 30
On Both Terminals:
Direct PC Downloads
Connecting the Download Computer
TRANZ 380 Reference Manual
Display Response
8. ENTER PASSWORD? Enter the system password to unlock memory information. The system password sup- plied with each terminal is 266831 (press: [1] [ALPHA] [ALPHA] [6] [6] [8] [3] [1]). How- ever, if you or the application programmer have already created a new password, enter the new password instead.
Q. *hee The terminal will display an asterisk for each key entered. After entering the complete password, press [FUNC/ENTER].
10. UNIT SENDING Shortly after the UNIT RECEIVE message DOWNLOAD APPL is displayed, the master terminal will display UNIT SENDING. The slave terminal's dis- play will change to DOWNLOAD APPL.
11. DOWNLOAD DONE When the download is complete, both terminals will display the DOWNLOAD DONE prompt indicating the download was a success.
Press the [CLEAR] key on both terminals to display the idle prompt.
A direct PC download uses a cable to directly transfer an application program from a PC to your TRANZ 380 terminal. Due to the speed and simplicity of this procedure, direct PC downloads are ideal for downloading to many terminals prior to their deployment to permanent locations.
A direct PC download requires: ° A TRANZ 380 terminal * An IBM PC or compatible computer
* Acable: IBM-PC version, VeriFone part number 00446-05 (25 pin) IBM-AT version, VeriFone part number 00446-04 (9 pin)
* ZONTALK 2000, version 2.0 or higher - a proprietary software downloading program developed by VeriFone :
* A terminal application must be present on the PC before downloading 1. Connect the 8-pin DIN connector on the download cable to the 8-pin DIN connector on the rear of the TRANZ 380 terminal.
2. Connect the other end of the download cable to the COM1 or CON2 serial port on the download computer. The download software allows you to specify which COM port to use.
3. Follow instructions in "Performing the Direct PC Download" (on next page).