Page 51

M ANAGEMENT P ACKETS 11 PINpad Device Connection Test

11 PINpad Device Connection Test Checks the communications/connection between the controller and the PINpad device.

Category Support Mode

Comments

Packet Format

Interactive Diagnostic Tests PINpad 1000

PINpad 1000SE

D

D

If the connection is okay, the controller receives an ACK (acknowledgment) from the PINpad within a second. If the controller does not receive the ACK within a second, it assumes the PINpad unit is not attached. <SI> 11 <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

11 packet type

2

PINpad Connection Test

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 5 characters, minimum 5 characters

Example

<SI> 11 <SO>{LRC}

Protocol Controller

Transmission Direction

11 packet

------> <------

PINpad

ACK = LRC OK NAK = LRC incorrect

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

49

Page 52

M ANAGEMENT P ACKETS 12 Select Prompt Language

12 Select Prompt Language Selects the language used for the prompts.

Category Support Mode

Comments

Interactive Diagnostic Test PINpad 1000

PINpad 1000SE

D

D

The controller uses this packet to select the prompt language. There are two different languages from which to choose. Languages are selected from one of the listed single digit codes.

NOTE

Current firmware only supports English and Spanish prompts.

Packet Format

<SI> 12 [language code] <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

12 packet type

2

Select Language code

[language code] packet parameter

1

Language control Selection; • 1 = English • 2 = Spanish Note:

Any value besides 1 or 2 will result in no change, and the PINpad device will send out an <EOT>.

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 6 characters, minimum 6 characters

Example

<SI> 122 <SO>{LRC}

This example selects the Spanish language prompts (code = 2)

50

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Page 53

M ANAGEMENT P ACKETS 12 Select Prompt Language

Protocol Controller

Transmission Direction

12 packet

------> <------

PINpad

ACK = LRC OK NAK = LRC incorrect PINpad displays in selected prompt language.

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

51

Page 54

M ANAGEMENT P ACKETS 13 Set Baud Rate

13 Set Baud Rate The master device uses this packet to set the baud rate for RS232 communication with the PINpad device.

Category Support Mode

Comments

Interactive diagnostic tests PINpad 1000

PINpad 1000SE

D

D

After the new baud rate has been selected, the unit displays the new baud rate in the format "xxxx BPS" for 3 seconds, then returns to the idle prompt. There are five different baud rate selections: 1200, 2400, 4800, 9600, and 19200 bps. The default of a new PINpad device is 1200 bps. The baud rate setting is stored in backup RAM. The PINpad device retains any change to this default through subsequent power cycles.

NOTE

After power cycling memory test or battery power is lost, the baud rate setting is reset to the factory default. The current baud rate can be determined by using 01 Run Diagnostic Function Routine with diagnostic test # - '00.’

Packet Format

<SI> 13 [bc] <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

13 packet type

2

Set baud rate

[bc] packet parameter

1

Baud rate codes: • 1=1200 baud (default) • 2=2400 baud • 3=4800 baud • 4=9600 baud • 5=19200 baud

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 6 characters, minimum 6 characters

52

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Page 55

M ANAGEMENT P ACKETS 13 Set Baud Rate

NOTE

Examples

If code of [bc] is out of range or missing, the PINpad directly echoes EOT and defaults to 1200 baud. <SI> 134 <SO>{LRC} (9600 baud) <SI> 131 <SO>{LRS} (1200 baud) <SI> 138 <SO>{LRS} (1200 baud) <SI> 13 <SO>{LRC}

(1200 baud)

PINpad Protocol Controller

Transmission Direction

13 packet

------> <------

PINpad

ACK = LRC OK NAK = LRC incorrect

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

53

Page 56

M ANAGEMENT P ACKETS 15 Refresh PINpad Key Management Mode

15 Refresh PINpad Key Management Mode The master device uses this packet to set the key management mode of the PINpad device. After the new key management mode has been selected, the PINpad device displays the new key management mode for 3 seconds, then returns to the idle prompt.

Category

Interactive diagnostic tests

Support Mode

PINpad 1000

PINpad 1000SE

D

D

PINpad Mode Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

15 packet type

2

Key Management Mode

[keycode] packet parameter

4-5

Key Management Codes: • 'MKEY' - Master Session • 'DKEY' - DUKPT • 'DUAL' - Master + DUKPT • others - no change

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error check character

Packet Length: maximum 9 characters, minimum 8 characters

PINpad Mode Comments

The master device uses this packet to change between the following key management modes supported by the PINpad:

•

VISA MASTER SESSION+DUKPT mode (default)

•

MASTER SESSION only mode

•

DUKPT only mode

After the new key management mode has been selected, the PINpad device displays the new key management mode for 3 seconds, then returns to the idle prompt. NOTE

54

Once the key management scheme is selected, it will be retained across power cycles. When switching between key management modes, sensitive data will be erased according to the following table (only in PINpad 1000SE mode -- no keys are erased in PP1000 mode).

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Page 57

M ANAGEMENT P ACKETS 15 Refresh PINpad Key Management Mode

PINpad Mode Request Format

From

To: DUAL

To: MKEY

To: DKEY

DUAL

No Change

Erase All DUKPT Engines keys

Erase M/S keys and KLK

MKEY

No Change

No Change

Erase All keys and KLK

DKEY

No Change

Erase All keys and KLK

No Change

<SI> 15 [keycode] <SO>{LRC}

PINpad Mode Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

15 packet type

2

[keycode] packet parameter

4-5

Available Key Management Codes: • 'MKEY' - Master Session • 'DKEY' - DUKPT • 'DUAL' - Master + DUKPT • others - no change

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error check character

Packet Length: maximum 10 characters, minimum 9 characters NOTE

PINpad Mode Response Format

If code of [keycode] is out of range or missing, the packet command will be ignored and aborted by an <EOT>. <SI> 15 [keycode] <SO>{LRC}

PINpad Mode Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

15 packet type

2

Set Key Management Mode

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

55

Page 58

M ANAGEMENT P ACKETS 15 Refresh PINpad Key Management Mode

Type

Field

Length

Description

[keycode] packet parameter

4

Current Key Management Codes: • 'MKEY' - Master Session • 'DKEY' - DUKPT • 'DUAL' - Master + DUKPT • others - no change

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error check character

Packet Length: maximum 9 characters, minimum 10 characters

Examples

<SI> 15 MKEY <SO>{LRC} Sets PINpad to Master Session mode <SI> 15 DKEY <SO>{LRS} Sets PINpad to DUKPT mode <SI> 15 DUAL <SO>{LRS} Sets PINpad to dual (Master + DUKPT) mode

Protocol Controller

Transmission Direction

15 packet

------> <------

PINpad

ACK = LRC OK NAK = LRC incorrect (EOT after 3 NAKs)

<-----ACK = LRC OK

15 packet

------>

NAK = LRC incorrect (EOT after 3 NAKs) <-----NOTE

56

EOT to terminate process

If the controller receives the response without any error, then it sends an ACK to the PINpad. Then PINpad then sends an <EOT> to terminate the session.

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Page 59

M ANAGEMENT P ACKETS 17 Set Key Management Mode

17 Set Key Management Mode Provides additional PINpad Key Management configuration by setting or clearing control-switches in the Key Management Options Register.

Support Mode

Comments

NOTE

PINpad 1000

PINpad 1000SE

D

D

This packet allows additional PINpad Key Management configuration through setting control-switches in the Key Management Options Register. The PINpad 1000SE supports the following additional functions compared to the PINpad 1000/ PINpad 1000+:

•

3DES DUKPT Support

•

GISKE Master-Session Key Support

•

Secure Messaging

•

Zero Key Support

•

Empty GISKE Key Support

•

MAC-ed Prompt Support

The new MAC alternatives apply only when GISKE is active, and are selected by key attribute and not by key management switch. For compatibility, the default Key Management mode in PINpad is set to MSDUKPT/ Single DES interleaving mode. Once a new key management scheme is selected, it will be retained during the power cycle.

NOTE

Setting a new mode causes the PINpad to erase all existing keys or non-volatile security values stored for secure messaging. For Key Management Mode Register values, see the following table: Table 3

Key Management Mode Register Values Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

1DES master session – Default

-

-

-

-

-

0

0

0

Mixed Mode (1DES & 3DES GISKE)

-

-

-

-

-

0

0

1

3DES GISKE master session

-

-

-

-

-

0

1

0

1DES DUKPT – Default

-

-

-

-

0

-

-

-

3DES DUKPT

-

-

-

-

1

-

-

-

DUKPT Engine 0

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

57

Page 60

M ANAGEMENT P ACKETS 17 Set Key Management Mode

PP1000 mode:

Bit 7

Bit 6

Bit 5

-

-

-

Bit 4

• Zero Key support off

Bit 3

Bit 2

Bit 1

Bit 0

-

-

-

-

-

-

-

-

0 1

• Zero Key support on – Default

PP1000SE mode:

-

-

-

• Zero Key support off – Default and always off.

0 1

• Zero Key support on – N/A

Empty GISKE session key support off – Default and always off for PP1000SE

-

-

0

-

-

-

-

-

Empty GISKE session key support on

-

-

1

-

-

-

-

- do nothing

-

0

-

-

-

-

-

-

Clear all MS master keys & KLK.

-

1

-

-

-

-

-

-

Rsvd

-

-

-

-

-

-

-

Reserved

One ASCII-Hex digit is used produce half of a control byte which the PINpad uses as the DUKPT Engine 1/3 Mode Flag (DEMF): Table 4

DUKPT Engine 1/3 Mode Flag (DEMF) Bit 3

Bit 2

Bit 1 (DUKPT Engine "2")

Bit 0 (DUKPT Engine "1")

1DES DUKPT - Default

0

3DES DUKPT

1

1DES DUKPT - Default

0

3DES DUKPT

1

Reserved Reserved

Reserved Reserved

Examples:

Packet Format

•

DEMF = 0x30 equates to 1DES for Engine “1” and 1DES for Engine “2”

•

DEMF = 0x32 equates to 3DES for Engine “1” and 1DES for Engine “2”

•

DEMF = 0x32 equates to 1DES for Engine “1” and 3DES for Engine “2”

•

DEMF = 0x33 equates to 3DES for Engine “1” and 3DES for Engine “2”

<SI> 17 [KMM] [DEMF] <SO>{LRC}

Elements

58

Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

17 packet type

2

Set Key Management Mode

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE