Page 31

M ANAGEMENT P ACKETS M02 Check PINpad Mode

M02 Check PINpad Mode Causes the PINpad unit to check the PINpad mode.

Support Mode

Comments

PINpad 1000

PINpad 1000SE

D

D

For PINpad Mode Register values, see the following table: Table 2

PINpad Mode Register Values Bit 7

Request Format

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

PP1000 mode: Default

- - - - - - - - - - - Reserved - - - - - - - - - -

0

0

1

PP1000SE mode

- - - - - - - - - - - Reserved - - - - - - - - - -

0

1

0

<SI> M02 <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

M02 packet

3

Check PINpad Mode

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 6 characters, minimum 6 characters

Response Format

<SI> M02 [PM] <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

M02 packet

3

Check PINpad Mode

[PM] packet parameter

2

The two ASCII-Hex digits are concatenated, big-endian, to produce a single control byte. See the PINpad Mode Register Values, above, for values.

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 8 characters, minimum 8 characters

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

29

Page 32

M ANAGEMENT P ACKETS M02 Check PINpad Mode

Protocol Controller

Transmission Direction

M02 request packet

------>

PINpad

ACK = LRC OK NAK = LRC incorrect <------

(EOT after 3 NAKs)

<------

M02 response packet

ACK = LRC OK NAK = LRC incorrect (EOT after 3 NAKs)

------> <------

30

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

EOT to terminate process

Page 33

M ANAGEMENT P ACKETS M03 Load Permanent Unit Serial Number

M03 Load Permanent Unit Serial Number Loads the permanent unit serial number (PUSN).

Support Mode

Comments NOTE

PINpad 1000

PINpad 1000SE

D

D

The default PUSN is all zeros '0' (0x30). This packet is only available in version 4E3002x and later releases of the firmware. Once the serial number is loaded it cannot be erased or changed. Subsequent M03 requests are ignored and return an error code.

CAUTION

There is no Power Failure Protection in Packet M03 processing. Load PUSN only in an environment where the power level can be guaranteed. Both the request and response formats are shown below.

Request Format

<SI> M03 [PUSN] <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

M03 packet

3

Load PUSN

[PUSN] packet

11

Permanent Unit Serial Number Format: xxx-xxx-xxx Note:

PUSN has input range from ‘0’ ~ ’9’, ‘A’ ~ ‘Z’ and ‘-’. Location and number of ‘-‘are not restricted or limited.

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 17 characters, minimum 17 characters

Response Format

<SI> M03 [r] <SO>{LRC}

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

31

Page 34

M ANAGEMENT P ACKETS M03 Load Permanent Unit Serial Number

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

M03 packet

3

Load PUSN

[r] packet parameter

1

Response Code; • 0=no error • 1=PUSN format error, input is outside the range of ‘0’ ~ ’1’, ’A’ ~ ’B’, or ‘-‘. • 2=PUSN is already loaded, and the

M03 request is ignored. <SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 7 characters, minimum 7 characters

Protocol Controller

Transmission Direction

M03 request packet

------>

PINpad

ACK = LRC OK NAK = LRC incorrect <------

(EOT after 3 NAKs)

<------

M03 response packet

ACK = LRC OK NAK = LRC incorrect (EOT after 3 NAKs)

------> <------

32

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

EOT to terminate process

Page 35

M ANAGEMENT P ACKETS M04 Read Permanent Unit Serial Number

M04 Read Permanent Unit Serial Number Checks the permanent unit serial number (PUSN).

Support Mode

Comments NOTE

Request Format

PINpad 1000

PINpad 1000SE

D

D

Both the request and response formats are shown below. This packet is only available in version 4E3002x and later releases of the firmware. <SI> M04 <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

M04 packet

3

Check PUSN

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 6 characters, minimum 6 characters

Response Format

<SI> M04 [PUSN] <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

M04 packet

3

Check PUSN

[PUSN] packet parameter

11

Permanent Unit Serial Number Format: xxx-xxx-xxx

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh'

{LRC} block code check

1

Error Check Character

Packet Length: maximum 17 characters, minimum 17 characters

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

33

Page 36

M ANAGEMENT P ACKETS M04 Read Permanent Unit Serial Number

Protocol Controller

Transmission Direction

M04 request packet

------>

PINpad

ACK = LRC OK NAK = LRC incorrect <------

(EOT after 3 NAKs)

<------

M04 response packet

ACK = LRC OK NAK = LRC incorrect (EOT after 3 NAKs)

------> <------

34

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

EOT to terminate process

Page 37

M ANAGEMENT P ACKETS 01 Run Diagnostic Function Routine

01 Run Diagnostic Function Routine Causes the PINpad unit to run self-diagnostic functions and send information to the master device.

Category Comments

Interactive Diagnostic Test The response packets to Packet 01 are packet 09 UART Loopback Test and Response Packet 14. This test is initiated by the controller. The PINpad displays the response to this diagnostic test. The table of two-byte ASCII code for diagnostic testing is as follows:

Packet Format

Diagnostic #

Description

PP1000 and PP1000SE modes

00

Change Proc Msg

Yes

01

RAM Test/One time

Yes

02

RAM Test/Continuous

Yes

03

PROM Checksum Test

Yes

04

Keyboard Test

Keyboard Test

05

Display Test

Display Test

06

Serial Number Check

Yes

07

UART Loopback Test

Yes

08

Current BAUD Rate

Yes

----

----

----

----

----

----

----

----

----

12

RAM Test/One Time

Yes

13

RAM Test/Continuous

Yes

14

PROM Checksum Test

Yes

15

PINpad ROM Version #

Yes

<SI> 01 [diagnostic#] <SO>{LRC}

Elements Type

Field

Length

Description

<SI> start of packet

1

ASCII Shift In Control Character; Value: `0Fh'

01 packet type

2

Interactive Diagnostic Routine

[diagnostic#] packet parameter

2

Two-byte ASCII code for the diagnostic test to run; Range: 00-09 (See the preceding table)

<SO> end of packet character

1

ASCII Shift Out Control Character; Value: `0Eh' PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

35

Page 38

M ANAGEMENT P ACKETS 01 Run Diagnostic Function Routine

Type

Field

Length

Description

{LRC} block code check

1

Error Check Character

Packet Length: maximum 7 characters, minimum 7 characters

Examples

<SI> 0101 <SO>{LRC}

This packet sends the PINpad the request to run diagnostic test 1, the one-time RAM test. <SI> 0106 <SO>{LRC}

This packet sends the PINpad device a request to run diagnostic test 6, which displays the serial number.

Protocol

This protocol is used with diagnostic numbers 01 through 06, as well as 08. Diagnostic Numbers 01-06 and 08 The following is the protocol for options 01-06 and 08. Controller

Transmission Direction

01 packet

------> <------

PINpad

ACK = LRC OK NAK = LRC incorrect PINpad executes test

<------

EOT when test finished

UART Loopback Test (07) The following is the protocol for option 07, the UART Loopback Test option. Controller

ACK = LRC OK

Transmission Direction

PINpad

<------

09 request packet

------>

NAK = LRC incorrect (EOT after 3 NAKs) 09 response packet

------> <------

ACK = LRC OK NAK = LRC incorrect

<-----ACK = LRC OK

09 response packet

------>

NAK = LRC incorrect (EOT after 3 NAKs) <------

36

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

EOT when test finished

Page 39

M ANAGEMENT P ACKETS 01 Run Diagnostic Function Routine

12 RAM Test/One Time The following is the protocol for option 12. Controller

Transmission Direction

01 packet:

------>

PINpad

<SI>0101<SO>{LRC}

<------

ACK = LRC OK NAK = LRC incorrect

<------

14 response packet: <SI>14RAM TST BEGIN<SO>{LRC}

ACK = LRC OK

------>

NAK = LRC incorrect (EOT after 3 NAKs) <------

14 response packet: <SI>14RAM TST OK<SO>{LRC} or <SI>14BAD RAM<SO>{LRC}

ACK = LRC OK

------>

NAK = LRC incorrect (EOT after 3 NAKs) <------

EOT to terminate process

13 RAM Test/Continuous The following is the protocol for option 13. Controller

Transmission Direction

01 packet:

------>

PINpad

<SI>0102<SO>{LRC}

<------

ACK = LRC OK NAK = LRC incorrect

<------

14 response packet: <SI>14RAM TST BEGIN<SO>{LRC}

ACK = LRC OK

------>

NAK = LRC incorrect (EOT after 3 NAKs) <------

14 response packet: <SI>14RAM TST OK<SO>{LRC} or <SI>14BAD RAM<SO>{LRC}

ACK = LRC OK

------>

NAK = LRC incorrect (EOT after 3 NAKs) <------

EOT to terminate process

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

37

Page 40

M ANAGEMENT P ACKETS 01 Run Diagnostic Function Routine

14 PROM Checksum Test The following is the protocol for option 12. Controller

Transmission Direction

01 packet:

------>

PINpad

<SI>0103<SO>{LRC}

<------

ACK = LRC OK NAK = LRC incorrect

<------

14 response packet: <SI>14xx<SO>{LRC}

ACK = LRC OK

------>

NAK = LRC incorrect (EOT after 3 NAKs) <-----NOTE

38

EOT to terminate process

In the preceding table, xx is the one-byte PROM internal checksum. There are two checksums inside the PINpad 1000SE. One is the PROM checksum, used for manufacturing purposes, which is 2 bytes long and located at 3FFE/3FFF. The other one is the PROM internal checksum.

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE