Page 211

APPENDIX G Manual Diagnostic Procedures There are two built-in diagnostics modes, Level 1 Diagnostic and Level 2 Diagnostic. From these modes, user can perform various tests and operation using the PINpad keypad.

Level 1 Diagnostic

You'll need your system password to enter Diagnostic Level 1 Upon entry, the PINpad will cycle through a menu of eight available diagnostics, which include changing messages, performing one-time and continuous RAM, PROM check, UART loopback tests, and display baud rate. To access this diagnostic level: Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER]. If the password is incorrect, the display will return to idle prompt. Otherwise, the PINpad will repeatedly cycle through the diagnostic menu until a selection is made.

/=SHOW P SER NUM 0=CHG PROC MSG 1=ONE MEM TST 2=CON MEM TST 3=PROM CKSUM

The terminal will cycle through the maintenance and diagnostic menu. Press the numeric key (0-9) that corresponds to the desired selection.

4=KEY TST

If you want to return to the idle prompt, press [CLEAR].

5=DISP TST

Note:

6=SHOW SER NUM 7=SUART LOOP

According to the mode setting, different mode might have different menu items (TBD).

8=DSP BAUD RATE 9=DSP KEY MGT

SHOW P SER NUM

Select the backspace to display the Permanent Unit Serial Number (PUSN). Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press Backspace.

/=SHOW P SER NUM… serial number

Indicates the permanent unit serial number. Compare the serial number to the one on the external label. Press [CLEAR] to return to idle prompt.

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

209

Page 212

M ANUAL D IAGNOSTIC P ROCEDURES Level 1 Diagnostic

CHG PROC MSG

Select option 0 to toggle between PIN PAD/PROCESSING (the default) or PIN PAL/PROCESSING displays. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [0].

0=CHG PROC MDG… PIN PAL/ PIN PAD

ONE MEM TST

Indicates you toggled to the PIN PAL/PIN PAD display. Displays for three seconds then returns to the idle prompt.

Select option 1 to initiate a single RAM memory test. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [1].

1=ONE MEM TST…

CON MEM TST

RAM TST BEGIN

The PINpad will run the RAM memory test.

RAM TST OK

RAM test completed without error. Idle prompt follows.

Select option 2 to initiate a continuous RAM test. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [2].

2=CON MEM TST…

PROM CKSUM

RAM TST BEGIN

The PINpad runs the continuous RAM test.

RAM TST OK

Press and hold down [CLEAR] to return to the idle prompt.

Select option 3 to initiate a PROM checksum test from the PINpad. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [3].

3=PROM CKSUM… PROM OK

Indicates test completed without error. Idle prompt follows.

210

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Page 213

M ANUAL D IAGNOSTIC P ROCEDURES Level 1 Diagnostic

KEY TST

Select option 4 to initiate a keypad reliability test. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [4].

4=KEY TST… xxxxxxx

Press any key on the keyboard. Number 0-9 or an upside down A (for [ENTER] key) is repeated 8 times on the display. Press [CLEAR] to return to idle prompt.

DISP TST

Select option 5 to verify the PINpad display is working properly. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [5].

5=DISP TST… 0'0'0'0'0'0 ****** *'0.

These three tests patterns will appear, one after another, on the display panel. Check that all segments of the pattern are lighting properly. Be sure the third test only display three characters. If more characters are display, the display is "ghosting." If some of the segments are not lit, or if the display does not match what you see in this manual then the unit need to be repaired. After displaying the sets, the PINpad returns to the idle prompt.

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

211

Page 214

M ANUAL D IAGNOSTIC P ROCEDURES Level 1 Diagnostic

SHOW SER NUM

Select option 6 to display the serial number stored internally for the PINpad. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [6].

6=SHOW SER NUM… serial number

Shows the unit serial number. Press [CLEAR] to return to idle prompt.

SUART LOOP

Select option 7 to check the receiver/transmitter circuitry. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [7].

7=SUART LOOP… SUART TST

Indicates UART loopback test started. Wait for results.

SUART OK/

If "SUART OK" is displayed, the test was successful. If "ERR-BAD COM" is displayed, the test failed.

ERR-BAD COM

DSP BAUD RATE

Select option 8 to display the PINpad current baud rate. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

Menu cycle...

Press [8].

8=DSP BAUD RATE… xxxx BPS

DSP KEY MGT

212

Displays the current baud rate in one of 1200 / 2400 / 4800 / 9600 / 19200 BPS for 3 seconds then return to idle prompt.

Select option 8 to display the PINpad current key management mode. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [3].

PASSWORD

Press 83746 followed by [ENTER].

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Page 215

M ANUAL D IAGNOSTIC P ROCEDURES Level 2 Diagnostic

Display

Response

Menu cycle...

Press [9].

9=DSP KEY MGT… Xxxxxxx

Displays the current key management, it will be one of the following: • 'MASTER SESSION' • 'DUKPT' • 'MASTER+DUKPT' • ‘SEMP/4B’

Level 2 Diagnostic NOTE

Diagnostic level 2 allow you to reinitialize and clear RAM and select and display different prompt languages and set PINpad baud rate.

This level requires an additional diagnostic password and is intended for field service and manufacturing personnel only. To access this diagnostic level: Display

Response

(idle prompt)

Press [CLEAR] immediately followed [2].

PASSWORD

Press 844747746 followed by [ENTER]. If the password is incorrect, the display will return to idle prompt. Otherwise, the PINpad will repeatedly cycle through the diagnostic menu until a selection is made.

1=P.C.MEM TST

The terminal will cycle through the menus.

2=INIT MKEY RAM 3=LANGUAGES

Press the numeric key (1-6) that corresponds to the desired selection.

4=DSP ALL MSG

Note:

5=SET BAUD RATE

According to the mode setting, different mode might have different menu items (TBD).

6=SET KEY MGT

P.C. MEM TST

Select option 1 to perform the nonvolatile RAM initialization test used in the manufacturing "burn-in" process. In nonvolatile initialization, the master key buffer is emptied and the correct master key checksum is calculated.

CAUTION

This option should be used to reinitialize the PINpad only.

Display

Response

(idle prompt)

Press [CLEAR] immediately followed [2].

PASSWORD

Press 844747746 followed by [ENTER]. PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

213

Page 216

M ANUAL D IAGNOSTIC P ROCEDURES Level 2 Diagnostic

Display

Response

Menu cycle...

Press [1].

1=P.C.MEM TST… FILLING MEMORY

The PINpad loads each memory location with unique data.

********

These prompt are display repeatedly unless the unique data in one of the memory locations was changed, and will prompt as:

"0.'0.'0.'0. MEMORY OK

Press [CLEAR] in any case to return to the idle prompt.

******** ILLEGAL MEMORY

INIT MKEY RAM

Select option 2 to clear all master keys RAM. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [2].

PASSWORD

Press 844747746 followed by [ENTER].

Menu cycle...

Press [2].

2=INIT MKEY RAM…

LANGUAGES

Select option 3 to set the language displayed in prompts. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [2].

PASSWORD

Press 844747746 followed by [ENTER].

Menu cycle...

Press [3].

3=LANGUAGES… Menu cycle... 1=ENGLISH 2=SPANISH (language)

This menu shows the language available in the operating system. Press the numeric key (1-8) that corresponds to the desired language. The selected language name will appear for confirmation. For example, If you selected "2," the display will show "SPANISH." Press [CLEAR] to return to the idle prompt.

DSP ALL MSG

Select option 4 to display each individual prompt for the language selected in "LANGUAGES". Display

Response

(idle prompt)

Press [CLEAR] immediately followed [2].

PASSWORD

Press 844747746 followed by [ENTER].

Menu cycle...

Press [4].

4=DSP ALL MSG… 0=CHG PROC MSG 214

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Press [ENTER].

Page 217

M ANUAL D IAGNOSTIC P ROCEDURES Level 2 Diagnostic

Display

Response

1=ONE MEM TST

Press [ENTER].

2=CON MEM TST

The PINpad will continue to display another prompt each time you press [ENTER] until it reaches the end of the prompt table.

…

Press [CLEAR] to return to the idle prompt.

SET BAUD RATE

Select option 5 to set the RS-232 baud rate of PINpad. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [2].

PASSWORD

Press 844747746 followed by [ENTER].

Menu cycle...

Press [5].

5=SET BAUD RATE… 1=1200 BPS 2=2400 BPS

Alternate display these 5 prompts, by entry one of 1~5 to select the desired baud rate.

3=4800 BPS

Note:

4=9600 BPS 5=19200 BPS xxxx BPS

SET KEY MGT

Pressing [CLEAR] will return to idle prompt without setting. Pressing other key, the PINpad will alternate display these 5 prompts again for re-entry.

To display set baud rate for 3 seconds then return to idle prompt.

Select option 6 to set the key management mode of PINpad. Display

Response

(idle prompt)

Press [CLEAR] immediately followed [2].

PASSWORD

Press 844747746 followed by [ENTER].

Menu cycle...

Press [6].

6=SET KEY MGT… 0=MASTER SESSION 1=DUKPT 2=MASTER+DUKPT

Alternate display these prompts, by entry one of 0~2 to select the desired key management. When changing the key management mode of PINpad, key erasing rules are applied, please refer to the 15 Refresh PINpad Key Management Mode for more details. Note:

xxxxxxxx

Pressing [CLEAR] will return to idle prompt without setting. Pressing other key, the PINpad will alternate display these 4 prompts again for re-entry.

To display set key management for 3 seconds then return to idle prompt.

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

215

Page 218

M ANUAL D IAGNOSTIC P ROCEDURES Level 2 Diagnostic

216

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

Page 219

APPENDIX A Pinouts

The table in this appendix shows the pinouts for the PINpad 1000SE connector. Connector

1

4

Pin

Description

1

Circuit ground

2

Serial receive (serial data to PINpad)

3

Serial transmit (serial data from PINpad)

4

+9 volts DC (VDC) unregulated power

LOOKING INTO SOCKET

PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE

217

Page 220