Page 111
M ASTER /S ESSION M ESSAGE P ACKETS 02 Transfer Master Key
Communication Protocol - Key-only Format Each key stored in the PINpad contains its own key attributes. However, this is information is not available when key is loaded using the key-only format (as comparing to the GISKE communication protocol). Therefore, the PINpad sets the following default attributes to the key: Key Attributes
Value
Hex
Definition
Key Usage
‘AN’
0x41, 0x4E
Any, no special restrictions
Key Algorithm
‘D’
0x44
DES
Key Mode of Use
‘N’
0x4E
No special restrictions
Key Version
‘00’
0x30, 0x30 version = zero
Key Length
‘1’
0x31 single length key
The single-DES communication protocol between Master Device and PINpad is described below. Controller
Transmission Direction request packet:
------>
PINpad
<SI>02[n][hhhhhhhhhhhhhh hh]<SO>{LRC}
<------
ACK = LRC OK NAK = LRC incorrect (EOT after 3 NAKs)
<------ response packet: <SI>02[n][hhhhhhhhhhhhhh hh]<SO>{LRC}
ACK = LRC OK, and key echo OK
------>
NAK = LRC incorrect
The PINpad saves new master key ONLY upon receipt of ACK. EOT terminates the entire session.
(EOT after 3 NAKs) EOT if LRC correct but key echo is incorrect <------
EOT
Sample Packet of Key-only Format <SI>0200123456789ABCDEF<SO>{LRC}
This sample packet requests the PINpad to load master key 0123456789ABCDEF into location '0'.
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
109
Page 112
M ASTER /S ESSION M ESSAGE P ACKETS 02 Transfer Master Key
Communication Protocol - GISKE Key Block Format The 3DES communication protocol between Master Device and PINpad is documented in the following section. Sample Packet of GISKE Key Block Format <SI>0200123456789ABCDEF0123456789ABCDEF0123456789ABCDEF0123456789ABCDEF01 23456789ABCDEF0123456789ABCDEF012345678901234567890123<SO>{LRC}
This sample packet requests the PINpad to load GISKE Key Block (120 bytes, shown below) to address [0]. GISKE Key Block: 0123456789ABCDEF0123456789ABCDEF0123456789ABCDEF0123456789ABCDEF012345678 9ABCDEF0123456789ABCDEF012345678901234567890123
Response Format Type
Field
Length
Description
<SI> start of packet
1
ASCII Shift In Control Character; Value: `0Fh'
02 packet type
2
Transfer Master Key
[r] packet parameter
1
Response Code [0 – 9] • 0 – No Error • 1 – Error, PINpad in incorrect KMM (for details, see Rules of Key Management Switching) • 2 – Error, incorrect Key Usage / Mode of Use / Algorithm / Key Length • 3 – Error, version error • 4 – Error, KLK already exists, new KLK is not encrypted from the previous KLK • 5 – Error, GISKE decryption/MAC error. • 6 – Error (This error is not applicable to the PINpad 1000SE). • 7 – Error, Inappropriate Master key addressing. <SO> end of packet character
1
ASCII Shift Out Control Character; Value: `0Eh'
{LRC} block code check
1
Error Check Character
Packet Length: maximum 6 characters, minimum 6 characters
Example Response <SI> 02 0 <SO>{LRC}
110
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
Page 113
M ASTER /S ESSION M ESSAGE P ACKETS 02 Transfer Master Key
Communication Protocol Controller
Transmission Direction request packet:
------>
PINpad
<SI>02[r][hhh.hhh]<SO>{L RC}
<------
ACK = LRC OK NAK = LRC incorrect (EOT after 3 NAKs)
<------ response packet: <SI>02[r]<SO>{LRC}
ACK = LRC OK, No error, and key echo OK
------>
NAK = LRC incorrect
The PINpad saves new master key ONLY upon receipt of ACK. EOT terminates the entire session.
(EOT after 3 NAKs) EOT if LRC correct but key echo is incorrect <------
EOT
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
111
Page 114
M ASTER /S ESSION M ESSAGE P ACKETS 04 Check Master Key
04 Check Master Key Verifies if the PINpad device has a master key already stored in a specific master key memory location.
Category Comments
Interactive Diagnostic Test The controller sends the request packet to verify if a master key is in a specific location. The PINpad device checks the key address and sends a response packet back to the controller indicating whether there is or is not a resident master key in that memory location. The PINpad unit has 10 master key memory locations. Use Packet 04 before sending new keys to prevent the accidental overwriting of a master key. Packet 04 has two types of communication format:
•
Key-only Format
•
GISKE Key Block Format
The communication format depends on the PINpad Key Management setting and length of the key at [address]. The usage of the communication protocol is described in following table. PINpad Key Management Setting
Key Length at [address]
1DES mode
1DES (single length key)
Key-only Format
3DES (single/ double/triple length key)
GISKE Key Block Format
1DES (single length key)
GISKE Key Block Format
3DES (double/triple length key)
GISKE Key Block Format
Mixed or 3DES mode
Communication Protocol Used
Note:
If a single/double/triple length key stored in the PINpad contains the Key Attributes information, then the Master Device will understand the GISKE Key Block Format communications protocol.
The formats for both the request to the PINpad unit and the response from the PINpad unit are shown below. NOTE
This option is disabled when the PINpad unit is set for DUKPT.
112
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
Page 115
M ASTER /S ESSION M ESSAGE P ACKETS 04 Check Master Key
Request Format
<SI> 04 [address] <SO>{LRC}
Request Format Elements Type
Field
Length
Description
<SI> start of packet
1
ASCII Shift In Control Character; Value: `0Fh'
04 packet
2
Master Key Check
[address] packet parameter
1
Master Key Address Range: 0-9 KLK address: F
<SO> end of packet character
1
ASCII Shift Out Control Character; Value: `0Eh'
{LRC} block code check
1
Error Check Character
Packet Length: maximum 6 characters, minimum 6 characters
Key-only Format Response Format
<SI> 04 [response code] <SO>{LRC}
Key-only Format Response Elements Type
Field
Length
Description
<SI> start of packet
1
ASCII Shift In Control Character; Value: `0Fh'
04 packet type
2
Master Key Check
[response] packet parameter
1
Response Code Range: • 0 = No Master Key at address • F = Master Key at address
<SO> end of packet character
1
ASCII Shift Out Control Character; Value: `0Eh'
{LRC} block code check
1
Error Check Character
Packet Length: maximum 6 characters, minimum 6 characters
Key-only Format Examples
<SI> 045 <SO>{LRC}
Packet requests the PINpad device check for the presence of a master key at its master key Memory Location 5. <SI> 040 <SO>{LRC}
Response packet indicates memory location doesn't contain master key (0). <SI> 04F <SO>{LRC}
This response packet indicates the memory location contains master key (F).
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
113
Page 116
M ASTER /S ESSION M ESSAGE P ACKETS 04 Check Master Key
GISKE Key Block Format Response Format
<SI> 04 [r] [kua] [a] [MOUA] [kv] [kl] <SO>{LRC}
GISKE Key Block Format Response Elements Type
Field
Length
Description
<SI> start of packet
1
ASCII Shift In Control Character; Value: `0Fh'
04 packet
2
Master Key Check
[r] packet parameter
1
Response Code • 0 - No Master Key at [address] • F - Master Key present at [address]
[kua] packet parameter
2
Key Usage Attribute (optional); used only if Master Key Present at address [a] Value – Definition • ‘AN’ – ANY * • ‘K0’ – Key Encryption or Wrapping • ‘G0‘ – MAC Generation • ‘M0’ – MAC Verification • ‘P0’ – Pin Encryption • ‘00’ = ISO 9797-1, MAC Algorithm 1 – 56 bits • ‘10’ = ISO 9797-1, MAC Algorithm 1 – 112 bits • ‘20’ = ISO 9797-1, MAC Algorithm 2 – 112 bits • ’30’= ISO 9797-1, MAC Algorithm 3 – 112 bits • ‘40’= ISO 9797-1, MAC Algorithm 4 – 112 bits • ‘50’= ISO 9797-1, MAC Algorithm 5 – 56 bits • ‘60’= ISO 9797-1, MAC Algorithm 5 – 112 bits
[a]
114 packet parameter
1
Note:
The original GISKE (ASCII-Hex) Key Usage Attribute value is saved in the RAM (2bytes).
Note:
ANY means that Key is available in the PINpad, but the Key was not loaded using GISKE format.
Algorithm Attribute (optional); used only if Master Key Present at address [a] Value
Definition [value stored in Key Attributes register]
• 'D'
DES
[0]
•
Reserved
[1]
•
Reserved
[2]
•
Reserved
[3]
• 'T'
TDES
[4]
•
Reserved
[5] ~ [F]
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
Page 117
M ASTER /S ESSION M ESSAGE P ACKETS 04 Check Master Key
Type
Field
Length
Description
[MOUA] packet parameter
1
Mode of Use Attribute (optional); used only if Master Key Present at address [a]
[kv] packet parameter
2
Value
Definition [value stored in Key Attributes register]
• 'N'
No special restrictions [0]
• 'E'
Encryption only
[1]
• 'D'
Decryption only
[2]
•
Reserved
[3]
• '0'
IV
[4]
• 'G'
MAC Generate
[5]
• 'V'
MAC Verify
[6]
• 'C'
Calculate = generate or verify [7]
•
Reserved
[8] ~ [F]
Key Version (optional); used only if Master Key Present at address [a] [kv] is a two-digit ASCII character version number, optionally used to prevent re-injection of old keys. If not used, this field is normally filled with ASCII '0' (0x30). Note:
[kl] packet parameter
1
The PINpad allocates 1 byte (per key) for each key version register.
Key Length (optional); used only if Master Key Present at address [a] Key Lengths can be: • "1" - single length key • "2" - double length key • "3" - triple length key Note:
The PINpad allocates 1 byte (per key) for each key version register.
<SO> end of packet character
1
ASCII Shift Out Control Character; Value: `0Eh'
{LRC} block code check
1
Error Check Character
Packet Length: maximum 13 characters, minimum 13 characters NOTE
To save storage space in RAM, both the Algorithm Attribute and the Mode of Use Attribute are individually converted to [x], a Hex number ranging form 0 ~ F (4 bits). In the response packet, the PINpad converts the each attribute number back to characters used in GISKE specification.
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
115
Page 118
M ASTER /S ESSION M ESSAGE P ACKETS 04 Check Master Key
Protocol Controller
Transmission Direction
04 request packet
------> <------
PINpad
ACK = LRC OK NAK = LRC incorrect
<------
PINpad checks requested memory location for 04 response packet 04 response packet
ACK = LRC OK
------>
NAK = LRC incorrect (EOT after 3 NAKs) <------
116
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
EOT
Page 119
M ASTER /S ESSION M ESSAGE P ACKETS 08 Select Master Key
08 Select Master Key Selects one of the 10 possible master keys (0-9) stored in the PINpad master key memory locations. NOTE
This option is disabled when the PINpad unit is set for DUKPT.
Category Comments
Interactive Diagnostic Test The master device sends this packet to the PINpad to select one of the ten possible master keys (0-9). VeriFone recommends that the controlling device always send this packet first before sending a packet requesting PIN entry (70/ Z60/Z62). VeriFone recommends that the master device should always send this packet first before sending a packet (e.g. Packet 70) to request PIN entry.
Packet Format
<SI> 08 [address] <SO>{LRC}
Elements Type
Field
Length
Description
<SI> start of packet
1
ASCII Shift In Control Character; Value: `0Fh'
08 packet type
2
Select Master Key
[address] packet parameter
1
Master Key address Range: 0-9
<SO> end of packet character
1
ASCII Shift Out Control Character; Value: `0Eh'
{LRC} block code check
1
Error Check Character
Packet Length: maximum 6 characters, minimum 6 characters
Example
<SI> 08 7 <SO>{LRC}
Selects master key 7.
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE
117
Page 120
M ASTER /S ESSION M ESSAGE P ACKETS 08 Select Master Key
Protocol Controller
Transmission Direction
08 packet
------> <------
PINpad
ACK = LRC OK NAK = LRC incorrect (EOT after 3 NAKs) PINpad makes selected master key current No response, if incorrect Master Key is selected (see Note).
<-----NOTE
118
EOT
If Master Key address does not contain any key, the PINpad will still set the currently selected key as the active master key due to the backward compatibility requirements. Functions requiring the usage of the "empty" active master key are responsible to carry out the error code response
PINPAD 1000SE REFERENCE AND PROGRAMMERS GUIDE