Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 5

Omni 5xxx and Vx5xx/Vx6xx Installation Guide, pages 31 to 40

Pages 31 to 40 of 50

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the VeriFone Omni 5100

Page 31

TERMINAL S ETUP Antenna

Antenna

For some Vx6xx terminals to establish a wireless connection, an external antenna is provided. This connection allows communication with your service provider to upload transaction data from the terminal and download system upgrades to the terminal. Radio service is activated by your service provider.

NOTE

Some Vx6xx terminals have an internal antenna and this section can be ignored. Use only the antenna designed for your unit. Failure to use the proper antenna results in the inability to establish a wireless connection.

CAUTION

Never hold the unit by the antenna; doing so may break the connection and void your warranty.

Installation This section only discusses Vx6xx terminals with external antenna. If the Vx6xx arrives from manufacture with the antenna unattached, use the following procedure to install the antenna:

1 Locate the antenna port on the back side of the Vx6xx terminal. 2 Align the connector on the end of the antenna with the connector on the end of the terminal.

3 Push gently on the center of the base of the antenna until it slides into position.

Figure 27

Align Antenna with Antenna Port

VX5XX/VX6XX INSTALLATION GUIDE

31

Page 32

TERMINAL S ETUP Antenna

4 Screw the barrel nut finger tight to retain the antenna.

Figure 28

Tighten Antenna Barrel Nut

Orientation To establish good wireless communication (uplink), vertically align the antenna with respect to ground and sky. For example, if standing and holding the terminal horizontally, position the antenna approximately at a 90° angle to the unit (that is, pointing up from the ground). This should point the antenna directly at the sky. If the unit is on a flat surface (for example, a table top) position the antenna so that it points directly at the sky. NOTE

If an application (for example, SoftPay) is installed in your Vx6xx unit, a signal strength indicator may appear on the display.

Replacing the If your Vx6xx terminal has difficulties completing wireless transactions, you may Antenna have to replace the antenna. Use the following procedure to replace the antenna: 1 Remove the existing antenna from the Vx6xx terminal: a Unscrew the barrel nut to loosen the antenna. b Pull gently on the center of the base of the antenna until it slides out of position.

2 Align the connector on the end of the new antenna with the connector on the end of the terminal.

3 Push gently on the center of the base of the antenna until it slides into position.

4 Screw the barrel nut finger tight to retain the antenna.

32

VX5XX/VX6XX INSTALLATION GUIDE

Page 33

TERMINAL S ETUP Wireless Transactions

Wireless To conduct a wireless transaction: Transactions • Ensure the terminal is in an optimal position for transmitting. •

Smart Card Transaction

Follow the on-screen instructions provided with your application.

The smart card transaction procedure may vary from one application to another. Verify the procedure with your application provider before performing a smart card transaction.

To Conduct a Smart 1 Card Transaction

Position a smart card with the contacts facing upward (see Figure 29).

2 Insert the smart card into the smart card reader slot in a smooth, continuous motion until it seats firmly.

3 Remove the card only when the application indicates the transaction is complete.

Figure 29 CAUTION

Magnetic Card Reader Use

Inserting a Smart Card

Leave the smart card in the card reader until the transaction is complete. Premature card removal will invalidate the transaction. The Vx5xx/Vx6xx supports credit/debit card transactions.

To Conduct a Credit/ 1 Debit Card Transaction

Position a magnetic card with the stripe in the card reader and facing inward, toward the keypad.

2 To ensure a proper read of the magnetic swipe card, the user should insert the magnetic card from the top of the unit, as shown in Figure 30.

VX5XX/VX6XX INSTALLATION GUIDE

33

Page 34

TERMINAL S ETUP Magnetic Card Reader Use

3 Swipe the card through the magnetic card reader.

Figure 30

34

VX5XX/VX6XX INSTALLATION GUIDE

Using the Magnetic Card Reader

Page 35

CHAPTER 3 Specifications This chapter discusses power requirements, dimensions, and other specifications of the Vx5xx/Vx6xx terminal.

Power

Vx5xx/Vx6xx terminal: 9 V DC; 4.0 A

DC Power Pack

UL, ITE listed, Class 2 power supply:

a Input rated: 100 - 240V AC, 50/60 Hz b Output rated: 8.6 - 9.4V DC 4.0 A Barrel connector polarity:

Temperature •

Operating temperature: 0° to 40° C (32° to 104° F)

•

Storage temperature: -30° to + 60° C (-22° to 140° F)

•

Relative humidity: 5% to 90%; no condensation

External For Vx5xx: Dimensions • Length: 209.2 mm (8.2 in) •

Width: 101.8 mm (4.0 in)

•

Depth: 72 mm (2.8 in)

For Vx6xx with Internal Antenna:

•

Length: 209.2 mm (8.2 in)

•

Width: 101.8 mm (4.0 in)

•

Depth: 72 mm (2.8 in)

For Vx6xx with External Antenna:

•

Length: 214.2 mm (8.4 in)

•

Width: 101.8 mm (4.0 in)

•

Depth: 72 mm (2.8 in)

OMNI 5XXX AND VX5XX/VX6XX INSTALLATION GUIDE

35

Page 36

S PECIFICATIONS Weight

Weight

Terminal unit weight: 0.48kg (1.06 lb) For Vx5xx:

•

Omni 5100/5150 and Vx510, Omni 3730 Certifications and Regulations, VPN - 23218

•

Omni 5100/5150 and Vx5xx Quick Installation Guide, VPN - 23219

For Vx6xx:

NOTE

•

Omni 56xx and Vx6xx Certifications and Regulations, VPN - 23644

•

Omni 56xx and Vx6xx Quick Installation Guide, VPN - 23643

CDMA SAR compliance for body worn operating configurations is limited to the specific belt clips / holsters / accessories that have no metallic component in the assembly. The highest reported SAR values for Vx6xx terminals under the FCC ID B32OMNI5600C are: PMS modes (Part 22) - Body-worn 0.567mW/g, PCS modes (Part 24) - Body-worn 0.205mW/g. GSM/GPRS SAR compliance for body worn operating configurations is limited to the specific belt clips / holsters / accessories that have no metallic component in the assembly. The highest reported SAR values for Vx6xx terminals under the FCC ID B32OMNI5600G are: PMS modes (Part 22) - Body-worn 0.753 mW/g, PCS modes (Part 24) - Body-worn 0.564mW/g.

36

OMNI 5XXX AND VX5XX/VX6XX INSTALLATION GUIDE

Page 37

CHAPTER 4 Maintenance The Vx5xx/Vx6xx has no user-maintainable parts.

Clean the Terminal

To clean the terminal, use a clean cloth slightly dampened with water and a drop or two of mild soap. For stubborn stains, use alcohol or an alcohol-based cleaner.

CAUTION Never use thinner, trichloroethylene, or ketone-based solvents – they may cause deterioration of plastic or rubber parts. Do not spray cleaners or other solutions directly onto the keypad or terminal display.

Terminal Contacts

Gently swab the contacts with alcohol or contact cleaner to remove the dirt. It is important that the exposed contacts of the Vx6xx battery stay clean and unbent.

x CAUTION Avoid touching the contacts in the raised area in the center of the V 6xx battery and the recessed area on the terminal. Finger oils tarnish contacts, causing bad connections. When operating on battery power and experiencing a high occurrence of bad or incomplete data transfers, clean the contacts.

Smart Card Reader

Do not attempt to clean the smart card reader. Doing so may void any warranty. For smart card reader service, contact your VeriFone distributor or service provider.

OMNI 5XXX AND VX5XX/VX6XX INSTALLATION GUIDE

37

Page 38

M AINTENANCE Smart Card Reader

38

OMNI 5XXX AND VX5XX/VX6XX INSTALLATION GUIDE

Page 39

CHAPTER 5 VeriFone Service and Support For Vx5xx/Vx6xx terminal problems, contact your local VeriFone representative or service provider. For Vx5xx/Vx6xx product service and repair information:

Return a Terminal or Smart Battery for Service NOTE

•

USA – VeriFone Service and Support Group, 1-800-VeriFone (837-4366), Monday - Friday, 8 A.M. - 8 P.M., Eastern time

•

International – Contact your VeriFone representative

Before returning a Vx5xx/Vx6xx terminal, smart battery, or sled module to VeriFone, you must obtain an MRA number. The following procedure describes how to return one or more Vx5xx/Vx6xx terminals, smart batteries, or sled modules for repair or replacement (U.S. customers only).

International customers are advised to contact their local VeriFone representative for assistance regarding service, return, or replacement of terminals or batteries.

To Return a Terminal 1 for Service

Get the following information from the printed labels on the bottom of each Vx5xx/Vx6xx terminal, smart battery, or sled module to be returned:

•

Product ID, including the model and part number. For example, “OMNI 5100” and “Pxxx- xxx-xx,” “Mxxx-xx-xx-xxx,” or “2xxxx-xx”

•

Serial number (S/N xxx-xxx-xxx)

2 Obtain the MRA number(s) by completing one of the following: a Call VeriFone toll-free within the United States at 1-800-VeriFone and follow the automated menu options.

•

Select the MRA option from the automated message. The MRA department is open Monday to Friday, 8 A.M.–8 P.M., Eastern Time.

•

Give the MRA representative the information you gathered in Step 1. If the list of serial numbers is long, you can fax the list, along with the information gathered in Step 1, to the MRA department at 727-9534172 (U.S.).

b Address a fax to “VeriFone MRA Dept.” with the model and part number(s) •

Include a telephone number where you can be reached and your fax number. OMNI 5XXX AND VX5XX/VX6XX INSTALLATION GUIDE

39

Page 40

VERI F ONE S ERVICE AND S UPPORT Accessories and Documentation c Complete the Inquiry Contact Form at http://www.verifone.com/aboutus/ contact/contact_form.cfm.

NOTE

•

Address the Subject box with to “VeriFone MRA Dept.”

•

Reference the model and part number in the Note box.

One MRA number must be issued for each Vx5xx/Vx6xx terminal you return to VeriFone, even if you are returning several of the same model.

3 Describe the problem(s). 4 Provide the shipping address where the repaired or replacement unit must be returned.

5 Keep a record of the following items: •

Assigned MRA number(s).

•

VeriFone serial number assigned to the Vx5xx/Vx6xx terminal, smart battery, or sled module you are returning for service or repair (terminal serial numbers are located on the bottom of the unit.

•

Shipping documentation, such as air bill numbers used to trace the shipment.

•

Model(s) returned (model numbers are located on the VeriFone label on the bottom of the Vx5xx/Vx6xx terminal).

Accessories and Documentation

Power Pack

VeriFone produces the following accessories and documentation for the Vx5xx/Vx6xx terminal. When ordering, please refer to the part number in the left column.

•

VeriFone online store at www.store.verifone.com

•

USA – VeriFone Customer Development Center, 800-VeriFone (837-4366), Monday - Friday, 7 A.M. - 8 P.M., Eastern time

•

International – Contact your VeriFone representative Contact your local VeriFone distributor to determine which power pack or power cord fits your needs. CPS10936-3A DC power pack (universal)

Thermal Printer Paper

40

21973-01

AC power cord (US)

CRM0039-01

CRM0039 in 30-roll bulk package

CRM0040

High-grade thermal printer paper, 57 mm (2.24-inch) width, 25-meter (82-feet) length; single roll; Available in 20-roll or 50-roll bulk packages

OMNI 5XXX AND VX5XX/VX6XX INSTALLATION GUIDE