Page 21
TERMINAL S ETUP Connect Optional Device(s)
6 Replace the MSAM compartment door and reinstall the screw (see Figure 13).
Figure 13
Connect Optional Device(s) CAUTION
Closing MSAM Compartment Door
The Vx5xx/Vx6xx supports some peripheral devices designed for use with electronic point-of-sale terminals.
Before connecting any peripheral device, remove the power cord from the bottom of the terminal and ensure that the green indicator LED is not lit. Reconnect the power cord only after you are finished connecting the peripheral device(s). For complete information about peripheral installation and use, refer to the user documentation supplied with those devices. For more information about optional devices, please contact your VeriFone distributor.
NOTE
RS-232-type devices do not work on the PINpad port. PINpad-type devices do not work on the RS-232 port. If an optional peripheral device does not function correctly, check the port connection.
Vx5xx Optional For the Vx5xx, use the two ports on the back panel to connect up to two optional Device Connections devices. Connecting the PINpad or Smart Card Reader to the Vx5xx Use the following procedure to connect a PINpad or smart card reader.
1 Insert the RJ45-type connector on the end of the PINpad or smart card reader into the port on the back of the peripheral device. To install a PINpad 101, PINpad 201, or PINpad 1000, position and insert the grommet to secure the cable connection. If a cable is not already connected to the smart card reader or PINpad, insert the small modular plug on one end of the interface cable into the optional device’s modular jack. VX5XX/VX6XX INSTALLATION GUIDE
21
Page 22
TERMINAL S ETUP Connect Optional Device(s)
2 Insert the larger RJ45-type connector on the other end of the PINpad cable into the PINpad serial port on the bottom of the terminal.
Figure 14
Vx5xx Example PINpad Serial Port Connections
Connecting the Check Reader to the Vx5xx The Vx5xx terminal supports the CR 600 and CR 1000i check readers. Contact your VeriFone representative or visit the online store at www.store.verifone.com for information on these devices. Figure 15 provides an example of a peripheral connection to the RS-232 port. CAUTION
Check readers require a separate power source. Before connecting a check reader or similar device, remove the power cord from the bottom of the terminal and ensure that the green indicator LED is not lit.
Figure 15 22
VX5XX/VX6XX INSTALLATION GUIDE
Vx5xx Example Check Reader Connection
Page 23
TERMINAL S ETUP Connect Optional Device(s)
Vx6xx Optional The side port of the Vx6xx terminal can operate either as a PINpad port or an RSDevice Connections 232 port, depending on the power source available. Connecting the PINpad or Smart Card Reader to the Vx6xx When plugged in and not operating off battery power, the side port operates as a PINPad port and the terminal can be connected to a PINpad (see Figure 16). Use the following procedure to connect a PINpad or smart card reader.
1 Insert the RJ45-type connector on the end of the PINpad or smart card reader into the port on back of the peripheral device. To install a PINpad 101, PINpad 201, or PINpad 1000, position and insert the grommet to secure the cable connection. If a cable is not already connected to the smart card reader or PINpad, insert the small modular plug on one end of the interface cable into the optional device’s modular jack.
2 Insert the larger RJ45-type connector on the other end of the PINpad cable into the PINpad serial port on the side of the terminal. Figure 16 provides an example of a smart card reader and PINpad connection to the PINpad serial port.
Figure 16
Vx6xx Example PINpad Serial Port Connections
VX5XX/VX6XX INSTALLATION GUIDE
23
Page 24
TERMINAL S ETUP Connect Optional Device(s)
Connecting the Check Reader to the Vx6xx When operating off battery power and not plugged in, the side port operates as an RS-232 port and the terminal can be connected to a check reader. The Vx5xx/Vx6xx terminal supports the CR 600 and CR 1000i check readers. Contact your VeriFone representative or visit the online store at www.store.verifone.com for information on these devices. Figure 17 provides an example of a peripheral connection to the RS-232 port. CAUTION
Check readers require a separate power source. Before connecting a check reader or similar device, remove the power cord from the bottom of the terminal and ensure that the green indicator LED is not lit.
Figure 17
Vx6xx Example Check Reader Connection
External Printers Although all Vx5xx/Vx6xx variants have an internal thermal printer, it may be Supported convenient to print larger print runs (for example, daily or weekly reports) to an external printer. The Vx5xx/Vx6xx terminal supports the VeriFone P250, P350, P900, and P950 external printers. Contact your VeriFone representative or visit the online store at www.store.verifone.com for information on these devices. External printer connections are through the RS-232 port and require a separate power supply.
24
VX5XX/VX6XX INSTALLATION GUIDE
Page 25
TERMINAL S ETUP Connect the Terminal Power Pack
Connect the Terminal Power Pack CAUTION
When you have finished connecting optional peripheral(s), you are ready to connect the Vx5xx/Vx6xx terminal to the provided power source.
Using an incorrectly rated power supply may damage the terminal or cause it not to work as specified. Before troubleshooting, ensure that the power supply being used to power the terminal matches the requirements specified on the bottom of the terminal. (See Chapter 3, Specifications, for detailed power supply specifications.) Obtain the appropriately rated power supply before proceeding.
To Connect the 1 Terminal Power Pack
Insert the round barrel connector (see Figure 18 and Figure 19) into the power port, identified by the icon at right.
Figure 18
Vx6xx Power Pack Connection
Figure 19
Vx5xx Power Pack Connection
2 Route the cable through cable retainer to secure the power cord (see Figure 19). NOTE
The bottom of the Vx5xx has an integrated cable-retaining feature to secure the power cord to the terminal.
3 Insert the AC power cord into the power pack.
VX5XX/VX6XX INSTALLATION GUIDE
25
Page 26
TERMINAL S ETUP Smart Battery
4 Plug the AC power cord into a wall outlet or powered surge protector. WARNING
WARNING
NOTE
Do not plug the power pack into an outdoor outlet or operate the terminal outdoors.
Disconnecting the power during a transaction may cause transaction data files not yet stored in terminal memory to be lost.
To protect against possible damage caused by lightning strikes and electrical surges, consider installing a power surge protector. When the terminal has power, the terminal lights are activated and the green LED indicator remains lit. If an application is loaded in the terminal, it starts after the initial VeriFone copyright screen and usually displays a unique copyright screen. If no application is loaded in the terminal, DOWNLOAD NEEDED appears on screen after the initial VeriFone copyright screen.
Smart Battery
NOTE
The Vx6xx wireless terminal uses an Li-ion smart battery (see Accessories and Documentation for ordering information). The internal logic of the smart battery prevents both overcharging and undercharging (a fault condition in which the battery level goes well below the minimum acceptable charge and the battery becomes unusable). The Vx6xx terminal will operate on battery power or on power pack power. The smart battery charger in the terminal will be active whenever the power pack is connected. The following are features of the smart battery:
•
Two Li-ion cells
•
A fuel gauge module that
•
• monitors state of charge (voltage and current),
• communicates with the terminal (charge parameters and status to indicate full discharge),
• determines full charge capacity (on charge cycle and uninterrupted discharge cycle), and
• automatically shuts down when cell voltage is extremely low.
A safety circuit that
• 26
VX5XX/VX6XX INSTALLATION GUIDE prevents cell damage from overcharge, over-discharge, or overheating
Page 27
TERMINAL S ETUP Smart Battery
NOTE
• activates when the battery is left in an unused terminal for extended periods, and
• resets when battery voltage reaches a preset threshold during the charge cycle.
Conserve battery power by turning the Vx6xx terminal off when not in use. If the terminal is not to be used for several days, remove the battery from the terminal as it continues to discharge even when the terminal is turned off.
Installation The Vx6xx smart battery fits in a slot on the back of the Vx6xx terminal, as shown in Figure 20. The locking tab clicks when the battery is in place. The slot is keyed, so that there is only one way to insert the battery.
Figure 20
Install the Smart Battery
Removal To remove the Vx6xx smart battery, press the locking tab at the top of the battery and pull the smart battery from its slot.
Figure 21
Detaching the Smart Battery from the Vx6xx Terminal
Charging After unpacking your Vx6xx terminal, install the battery and connect the power pack to the unit for 6 hours. It is also recommended that the smart battery receive a periodic full discharge. To ensure a full discharge, use the unit until the battery is fully drained. The smart battery has a safety circuit to protect the Li-ion cells from overcharging and over-discharging. If the battery is over-discharged, the safety circuit shuts down the battery. The battery must then be recharged to restore operation. VX5XX/VX6XX INSTALLATION GUIDE
27
Page 28
TERMINAL S ETUP Install/Replace SIM Card (GSM/GPRS Models)
NOTE
The Vx6xx terminal automatically shuts off when the smart battery reaches the critically low charge state. If this occurs, the smart battery must be recharged for a minimum of 1/2 hour before it can power the terminal. It may take several recharge attempts to reset the safety circuit when charging a smart battery that has been discharged below this critical state.
Battery Life The Vx6xx smart battery can be charged and discharged hundreds of times, but will eventually wear out. When operating times are noticeably shorter than usual, it is time to buy a new battery (see Accessories and Documentation for ordering information). WARNING Do not dispose of batteries in a fire. Li-ion batteries must be recycled or disposed of properly. Do not dispose of Li-ion batteries in municipal waste sites.
Install/Replace SIM Card (GSM/GPRS Models)
The SIM (Subscriber Identity Module) card is a smart card inserted in the Vx6xx GSM/GPRS terminal that contains your GSM/GPRS radio account information. Use the following procedure to replace or install a SIM card.
1 Loosen the screw from the GSM/GPRS sled module at the back of the Vx6xx terminal.
Figure 22
28
VX5XX/VX6XX INSTALLATION GUIDE
Loosen Retaining Screw
Page 29
TERMINAL S ETUP Install/Replace SIM Card (GSM/GPRS Models)
2 Detach the GSM/GPRS sled module from the terminal.
Figure 23
Remove GSM/GPRS Sled Module
3 Insert the SIM into the cardholder at the back of the GSM/GPRS sled module.
Figure 24 NOTE
Insert SIM Card Into GSM/GPRS Sled Module
The SIM cardholder has a notch on one corner to ensure the SIM card is positioned correctly and for easy orientation in the cardholder. Before inserting the SIM card, position it as shown in Figure 24, with the card’s gold contacts facing down.
VX5XX/VX6XX INSTALLATION GUIDE
29
Page 30
TERMINAL S ETUP Install/Replace SIM Card (GSM/GPRS Models)
4 Replace the GSM/GPRS sled module in the terminal.
Figure 25
Replace GSM/GPRS Module
5 Tighten the retaining screw.
Figure 26
30
VX5XX/VX6XX INSTALLATION GUIDE
Tighten Retaining Screw