The text of a manual · part 4 of 6
MX800 Series Installation Guide, pages 27 to 32
Pages 27 to 32 of 40: Maintenance; Troubleshooting
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the VeriFone MX850, VeriFone MX860 and VeriFone MX870
Page 27
CHAPTER 3 Maintenance The MX800 Series terminal has no user-maintainable parts. The smart card implementation is a proprietary hardware solution that has no serviceable parts.
Cleaning the Terminal CAUTION
Smart Card Reader
To clean the terminal, use a clean cloth slightly dampened with water and a drop or two of mild soap. For stubborn stains, use alcohol or an alcohol-based cleaner. For best results, use the VeriFone Cleaning Kit (P/N 02746-01). Never use thinner, trichloroethylene, or ketone-based solvents as they may deteriorate plastic or rubber parts. Do not spray cleaners or other solutions directly onto the display. Do not attempt to clean the smart card reader. Doing so may void the warranty. For smart card reader service, contact your VeriFone distributor or service provider.
MX800 SERIES INSTALLATION GUIDE
21
Page 28
22
MX800 SERIES INSTALLATION GUIDE
Page 29
CHAPTER 4 Troubleshooting During normal, day-to-day operation of your MX800 Series terminal, it is possible for minor malfunctions to occur. Following are some examples of possible problems, and steps to resolve them. VeriFone follows stringent quality control standards in the manufacture of MX800 Series terminals. Each unit that leaves the factory has been rigorously tested to ensure quality and reliable operation. However, should you encounter a problem in operation, read this section for possible causes and solutions. CAUTION Perform only the procedures specified in this guide. For all other services, contact your local VeriFone distributor or service provider. Service conducted by parties other than authorized VeriFone representatives may void the product warranty. Each MX800 Series terminal is equipped with tamper-evident labels. Do not, under any circumstances, attempt to disassemble the terminal. The troubleshooting guidelines provided in this section identify various problems and suggest the appropriate corrective action(s). If you have problems operating your MX800 Series terminal, please read through these troubleshooting examples. If the problem persists, or if it is not described below, contact your local VeriFone representative for assistance.
Display is Blank
If the terminal display does not show correct or readable information, check all cable connections. If the problem persists, contact your local VeriFone representative for assistance.
Serial Port Does Not Work
The following are the corrective steps to be taken if the serial port does not work.
1
Check whether the device connected to the serial port of the multiport cable of the MX800 Series terminal has power and is functioning correctly. If possible, perform a self-test on the device.
2
The cable connecting the optional device to the MX800 Series terminal’s serial port may be defective. Try a different serial cable.
3
If the problem persists, contact your local VeriFone representative for assistance.
MX800 SERIES INSTALLATION GUIDE
23
Page 30
Transaction Fails to Process
The following are the corrective steps to be taken if the terminal does not process the transaction. There are several possible reasons why the terminal may not be operating correctly or processing transactions. To check the most likely causes, follow the steps below.
Step 1: Check the magnetic card reader
Step 2: Check the smart card reader
Step 3: Check the cable connections
No Response From the Stylus
24
1
Make sure that you are swiping cards correctly with the MX800 Series terminal. For the MX800 Series terminal reader, the black, magnetic stripe on the card should face down and towards the screen.
2
Perform a test transaction using several different magnetic stripe cards to ensure that the problem is not a defective card.
3
Process a transaction manually using the screen instead of the card reader. If the manual transaction works, the problem may be a defect in the card reader. Contact your VeriFone distributor or service provider.
4
If the manual transaction does not work, proceed to Step 3: Check the cable connections.
1
Make sure you are inserting the cards correctly with the MX800 Series terminal smart card reader. The chip on the card should face down and inward.
2
Perform a test transaction using several different smart cards to ensure that the problem is not with the card.
3
Ensure any MSAM cards are correctly inserted and that the cardholders are properly secured.
4
If the problem persists, contact your VeriFone distributor or service provider.
1
Ensure that all cables are correctly connected.
2
If cables are connected properly, check that the cable is in working order by connecting a known good cable. If transactions process with this cable, replace the defective cable.
3
If the problem persists, contact your local VeriFone representative for assistance.
The following are the corrective steps to be taken if the terminal does not respond to the stylus inputs. (This procedure does not apply to the MX830 terminal without touch screen.)
1
Check the documentation to ensure that the terminal supports this stylus.
2
Unplug the stylus that does not respond and connect a known working stylus.
3
If the problem persists, contact your local VeriFone representative for assistance.
MX800 SERIES INSTALLATION GUIDE
Page 31
Gap in Captured Signature
The following are the corrective steps to be taken if there is a gap in captured signature. (This procedure does not apply to the MX830 terminal without touch screen.)
1
Ensure that the stylus is pressed hard during signature capture.
2
If the problem persists, contact your local VeriFone representative for assistance.
No Response From the Touch Screen
The following are the corrective steps to be taken if the touch screen does not respond or displays the incorrect response. (This procedure does not apply to the MX830 terminal without touch screen.)
NOTE
The MX800 Series terminal requires a touch screen calibration at the time of installation. The terminal should be powered on and allowed to stabilize at normal operating temperature; usually this takes no longer than 30 minutes, even if the terminal was previously in a cooler or warmer location. The touch screen calibration procedure (below) should then be performed. To perform a touch screen (panel) calibration, follow this procedure:
1
Press the recessed button near the top of the Magnetic Stripe Reader with a straightened paper clip and hold while three LEDs in the MSR track turn on. Release the button when the middle LED turns off. Keep hands away from the display until the prompt appears for password entry.
2
Enter the password.
3
In System Mode, perform a manual touch screen compensation. Tap CONFIGURE > right blue arrow > CALIBRATE > CALIBRATE. Follow the directions on the display.
4
If the problem persists, contact your VeriFone representative for assistance.
MX800 SERIES INSTALLATION GUIDE
25
Page 32
26
MX800 SERIES INSTALLATION GUIDE