Page 13

CHAPTER 2 Installation This chapter describes the MX800 Series installation procedures and includes connection examples.

Installing the Device Unpacking

This section presents installation guidelines for the MX800 Series terminal.

Open the shipping carton and carefully inspect the contents for possible tampering or shipping damage.

WARNING

Do not use a damaged terminal.

MX800 SERIES INSTALLATION GUIDE

7

Page 14

Cable Tie-down Strap and Screw

Multiport Cable Power Pack

Stylus and Tether (Optional) Stylus Mounting Holster (Optional) Figure 1 To unpack the shipping carton

8

1

Example of Terminal Product Components

With the shipping carton right side up, open the top and remove all items from the carton:

•

Terminal unit

•

Cable tie-down strap and screw

•

Power pack (power supply)

•

Multiport cable

•

Stylus and tether (optional)

•

Mounting holster (optional)

2

Remove the protective plastic wrap from the display and other components.

3

Place the components on a table or countertop.

4

Save the shipping carton and packing material for repacking or moving in the future.

MX800 SERIES INSTALLATION GUIDE

Page 15

Selecting a Location

Use the following guidelines to select a location for the MX800 Series terminal.

1

Select a location for the terminal that offers adequate ventilation and protection and is convenient for the user and merchant.

WARNING

The MX800 Series terminal is designed for indoor use only.

2

3

Place the MX800 Series terminal on a flat surface, such as a table or countertop, or mount it on a mounting stand supplied by VeriFone. Avoid areas with:

•

Excessive heat or dust

•

Oil or moisture

•

Devices that cause excessive voltage fluctuations or electrical noise, such as air conditioners, fans, electric motors, neon signs, or high-frequency security devices

•

Direct sunlight or objects that radiate heat Position the terminal conveniently in relation to power and ECR or LAN connections.

WARNING Do not use the MX800 Series terminal near water, including a bathtub, wash bowl, kitchen sink, or laundry tub. Do not use in a wet basement or near a swimming pool.

4

Stand Mount

Before connecting the terminal to the power pack, complete the installation by connecting all the cables (see Connecting the Device and Power Up with the Multiport Cable).

In most retail spaces, the terminal is positioned on a stand mount. To install the terminal on the stand mount:

1

Install the stand mount on the countertop in the desired lane over an appropriate hole through which the wiring connections can be threaded.

2

Thread all wiring connections through the center of the stand mount.

3

Make all wiring connections.

4

Attach the cable tie-down strap with the supplied screw.

5

Align and seat the three pins on the top plate of the stand mount platform with the three key-hole slots on the bottom of the terminal (Figure 2).

MX800 SERIES INSTALLATION GUIDE

9

Page 16

6

Slide the terminal down until the unit seats securely.

Figure 2

PIN Protection Measures

Aligning MX800 Series Terminal with the Typical Mounting Plate

The following techniques can be employed to provide for effective screening of the PIN-entry keypad during the PIN entry process. These methods would typically be used in combination, though in some cases a method might be used singly.

•

Positioning of terminal on the check-stand in such a way as to make visual observation of the PIN-entry process infeasible. Examples include:

•

Visual shields designed into the check-stand. The shields may be solely for shielding purposes, or may be part of the general check-stand design.

•

Position the PED so that it is angled in such a way that PIN spying is difficult.

•

Installing PED on an adjustable stand that allows consumers to swivel the terminal sideways and/or tilt it forwards/backwards to a position that makes visual observation of the PIN-entry process difficult.

•

Positioning of in-store security cameras so that the PIN-entry keypad is not visible.

The following table describes the two preferred mounting methods and the recommended measure to protect from PIN capture in four observation corridors:

10

MX800 SERIES INSTALLATION GUIDE

Page 17

Table 4

Mounting Methods and Protection Measures Customer In Queue

Customers Elsewhere

On-Site Cameras

Use signage behind the PED

Install so that customer is between PED and next in queue

No action needed

Do not install within view of cameras

No action needed

Install so that customer is between PED and next in queue

No action needed

Do not install within view of cameras

Method

Cashier

Countertop without stand

Countertop with stand

VeriFone also recommends instruction of the cardholder regarding safe PIN-entry. This can be done with a combination of:

•

Signage on the PED

•

Prompts on the display, possibly with a “click-through” screen

•

Literature at the point of sale

•

A logo for safe PIN-entry process

Installing Optional Components

This section discusses the installation procedures for the optional components available for the MX800 Series terminal. Your terminal may already have some of these options, as modules can be installed at the factory or in the field.

Installing Countertop Wedge

The countertop wedge raises the rear section of the MX800 Series terminal by an angle of 10 degrees to facilitate use of the screen (Figure 3).

Figure 3 To install the countertop wedge

Countertop Wedge: Rear View of the MX800 Series Terminal

1

Align the pins in the countertop wedge with the two key holes on the bottom of the MX800 Series terminal (Figure 4).

2

Slide the countertop wedge firmly into position.

MX800 SERIES INSTALLATION GUIDE

11

Page 18

3

Route the multiport cable through the races in the countertop wedge or through the races underneath the wedge.

Figure 4

Installing the Countertop Wedge

.

Installing I/O Modules

Use the following steps to install optional I/O modules:

NOTE

The retaining screws are captive, which means they do not actually separate from their seats, but only from the mounting hole.

1

Loosen the module retaining screw on the bottom of the terminal (Figure 5) until the old module can slide out.

Figure 5

12

MX800 SERIES INSTALLATION GUIDE

Removing the old I/O Module

Page 19

2

Slide the module into place (Figure 6) and secure the retaining screw.

Figure 6

Installing MSAM Cards

Installing the Module

Follow the steps below to install smart cards (MSAM cards). Often merchants are issued MSAM cards to run small applications, such as loyalty programs. MSAM cards are used only with MX800 Series terminal smart card configurations.

1

Unplug the power pack from the multiport cable.

2

Place the terminal upside down on a soft, clean surface to protect the lens from scratches.

3

Remove the MSAM compartment door screw and rotate the door up and back to access the MSAM cardholders.

Figure 7

Removing the MSAM Compartment Screw and Door

MX800 SERIES INSTALLATION GUIDE

13

Page 20

4

Remove any previously installed MSAM card by sliding the card from the MSAM cardholder.

Figure 8 NOTE

Before inserting the MSAM card, position it with the card’s gold contacts facing the smart card reader end of the terminal. The cardholder connector base has a set of contacts and a notch on one corner to ensure the MSAM card is positioned correctly. The MSAM card has a notch on one corner to ensure that it fits into the connector base in only one way. The MSAM compartment door will not close properly if the MSAM cards are installed incorrectly.

5

Install an MSAM card by aligning the card and carefully sliding it within the guides on the cover until it is fully inserted.

Figure 9

14

Removing Installed MSAM Card

MX800 SERIES INSTALLATION GUIDE

Inserting the MSAM Card

Page 21

6

Reinstall the compartment cover and door screw.

Figure 10

Installing the Trimplate

The MX800 Series terminal can be fitted with interchangeable trimplates to customize the appearance of the terminal. MX870 trimplate installation is explained below. Trimplates for the MX860, MX850, and MX830 are snapped straight down and are not rocked into place.

1

Insert the trimplate by lining up the three notches of the face plate into the unit.

2

Firmly snap the top part of the trimplate to secure it.

Figure 11

Connecting the Device

WARNING

Reinstalling the Compartment Door and Screw

Installing the Trimplate

This section provides brief descriptions of possible MX800 Series terminal device connections and the power pack connection. For complete information about installing and using an optional device, see the user documentation supplied with that device. Ensure that the multiport cable is not connected to a power pack before attaching the multiport cable to the MX800 Series terminal.

MX800 SERIES INSTALLATION GUIDE

15

Page 22

Multiport Cable

The MX800 Series terminals use a multiport cable (Figure 12) to make most connections, including connections to:

• an ECR

• an Ethernet LAN

• a development/host PC

Figure 12

CAUTION

Sample Multiport Cable: Front and Rear

Improper installation or removal of the terminal connector may permanently damage the MX800 Series terminal. The following precautions must be taken with multiport cables:

16

•

Do not force the terminal connector into place.

•

Always make sure that all of the pins are lined up in correct parallel fashion before applying light pressure to snap the terminal connector into place.

•

Do not attempt to remove the terminal connector by pulling directly on the cable. Instead, firmly grasp the sides of the terminal connector with thumb and forefinger, then pull out at the same angle the connector on the terminal is facing.

•

Disconnecting the power source during transaction processing may cause loss of transaction data.

MX800 SERIES INSTALLATION GUIDE

Page 23

Connecting ECR in Tailgate Mode

To connect an ECR to the MX800 Series terminal, insert the multiport cable plug into the bottom socket on the terminal, as shown in Figure 13.

Figure 13

Example ECR Connection

MX800 SERIES INSTALLATION GUIDE

17

Page 24

Connecting to a Host PC

To connect the MX800 Series terminal to a development PC, see Figure 14, which shows a USB connection with the 23741-02-R multiport cable.

HOST COMPUTER FOR DOWNLOADS OR DEBUGGING

MX800 TERMINAL

USB PORT

MULTIPORT CONNECTOR

Figure 14

18

Host PC Connection

Connecting to the Ethernet LAN

To connect the MX800 Series terminal to an Ethernet LAN through the Ethernet port using a standard Ethernet cable, insert the LAN cable from the LAN router or hub into the Ethernet port on the multiport cable.

Connecting to USB Host or Hub

Connecting to a USB host or hub requires VeriFone USB cable (P/N 23741-02-R). To connect to a USB host or hub:

1

Insert the multiport cable plug into the bottom socket on the terminal and route the cable through the slots to the desired exit side.

2

Plug the USB connector of the multiport cable into the USB host or hub.

MX800 SERIES INSTALLATION GUIDE

Page 25

Power Up with the Multiport Cable

This section describes how to connect the MX800 Series terminal to a power source using the multiport cable.

NOTE

WARNING

If connected to an ECR, the MX800 Series terminal can receive power from the ECR.

Do not plug the power pack into an outdoor outlet or operate the terminal outdoors.

1

Make all other connections before connecting the power pack.

2

Insert the multiport cable connector into the port on the back of the terminal (see Figure 15).

3

Route the cable through the slots to the desired exit side.

4

Insert the plug from the power pack into the +12V receptacle on the multiport cable.

5

Plug the power pack into an indoor electrical power outlet (Figure 15).

Figure 15

Power Pack Connection

MX800 SERIES INSTALLATION GUIDE

19

Page 26

Calibrate Touch Screen

The MX800 Series terminal requires a touch screen calibration at the time of installation. The terminal should be powered on and allowed to stabilize at normal operating temperature; usually this takes no longer than 30 minutes, even if the terminal was previously in a cooler or warmer location. The touch screen calibration procedure (below) should then be performed. To perform a touch screen (panel) calibration, follow this procedure:

20

1

Press the recessed button near the top of the Magnetic Stripe Reader with a straightened paper clip and hold while three LEDs in the MSR track turn on. Release the button when the middle LED turns off. Keep hands away from the display until the prompt appears for password entry.

2

Enter the password.

3

In System Mode, perform a manual touch screen compensation. Tap CONFIGURE > right blue arrow > CALIBRATE > CALIBRATE. Follow the directions on the display.

MX800 SERIES INSTALLATION GUIDE