Page 11

RS232, continued Time Out The ACK/NAK function (see page 7) can be given a limited (ranging from 1 second to 10 seconds) or unlimited amount of time to operate. Default is “1 Second”.

Data Direction Three options are available for data direction: “Send to Host”, “Send to Host & Terminal”, and “Send to Terminal”. Default is “Send to Host”.

Receive Terminator A user-definable Receive Terminator can be inserted at the end of bar code data. Pre-defined receive terminators include: <t>: Tab <r>: Carriage Return <n>: Line Feed <d>: Any Digit <a>: Any Letter <*>: Interblock Delay <“>: “ (quotation marks) <dd>: character in hexadecimal notation <<>: < <>>: > The above special characters must be bracketed by < > symbols as shown. Function codes (F keys, cursor up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu) and must include surrounding brackets (<>). Letters and numbers should be entered directly by keyboard input without surrounding brackets (<>). Default is “None”.

• • • • • • • • • •

8

Scanner Configuration Manager

Page 12

Scanner Port Terminator, Use Code ID, Double Verification, Scanning Mode, Label Type, Aim Function for Long-Range Engine, Aim Time for Long-Range Engine, Preamble, and Postamble are the parameters for Scanner Port configuration.

Terminator The Terminator is a command that follows the input of bar code data. Four different terminators can be selected here: “Enter”, “Return (on numeric keypad)”, “Field Exit or Right Control”, or “None”. Alternative terminators (such as Tab) can be be configured via the Postamble function (see page 11). Default is “Enter” UPC-A A UPC-E E EAN-13 F Use Code ID EAN-8 FF I 2 of 5 I The Code ID function can be used to S 2 of 5 H identify the type of bar code that is Code 39 M being scanned by inserting an identifyCodabar N ing letter (refer to chart at right) at the Code 93 L beginning of the bar code output. Code 128 K For example, if the Code ID function is UCC/EAN128 ]C1 on, and a bar code string of “54321” MSI O was output as “M54321”, the bar code Code 32 T would thus be identified as type Code Plessey Code P 39. Label Code IV, V B Default is “No”. Toshiba Code C Code 11 / Telpen J Delta Code D Double Verification Double Verification enables the scanner to verify the accuracy of the output by outputting only after a specified number (from 0 to 7) of identical results. For instance, if 3 is selected, the scanner will not output the bar code data until it’s obtained 4 identical scan results. Because the scanner normally scans at a rate of 33 scans per second (unless it’s a wand), this process should take less than a fraction of a second, even for higher values. Default is “0-Off” Scanner Configuration Manager

9

Page 13

Scanner Port, continued Scanning Mode Actual bar code scanning can occur in six different ways: Trigger scan causes the scanner light to remain on as long as the trigger is depressed, whether the bar code is recognized or not. Flashing causes the scanner to flash continuously after the trigger is pressed until it detects a bar code and outputs the data. The scanner light will remain on in anticipation of another bar code for approximately 12 seconds, after which it will begin flashing again. A second trigger press stops the scanning. Multiscan allows multiple scans while holding down the trigger. One Press One Scan causes the scanner light to remain on after the trigger is briefly depressed until a bar code is detected and output. Test is similar to the Flash setting except that the scanner outputs bar code data in a rapid-fire manner as long as a bar code is presented to the scanner. Old Laser Flash causes the scanner to flash continuously after the trigger is pressed and will scan each bar code only once per presentation. A second trigger press stops the scanning. Continuous causes the scanner light to remain on and scan bar codes as they are presented. Bar codes can be “double scanned” only after a short interval. Default is “Trigger”

• • • • • • •

Label Type Toggle between reading only Positive and both Positive and Negative bar codes. Reading both positive and negative bar codes can be useful in the graphics industry when negative images must be proofed. Default is “Positive”.

Aim Function for Long Range Engine The Aim Function causes a laser scanner to output a “pin-point” aiming aid for a specified period of time (see below) to enable the user to more easily scan distant bar code labels. This function can be toggled on or off. Default is “No”. 10

Scanner Configuration Manager

Page 14

Scanner Port, continued Aiming Time for Long Range Engine The Aiming Time function specifies the duration of the Aim Function (see previous page). Length of duration can be specified from 500ms to 2 seconds, in half-second increments. Default is “1 second”.

Preamble Insert a string of characters prior to the actual scanned data. Pre-defined characters include: <t>: Tab <r>: Carriage Return <n>: Line Feed <d>: Any Digit <a>: Any Letter <*>: Interblock Delay <“>: “ (quotation marks) <dd>: character in hexadecimal notation <<>: < <>>: > The above special characters must be bracketed by < > symbols as shown. Function codes (F keys, cursor up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu) and must include surrounding brackets (<>). Letters and numbers should be entered directly by keyboard input without surrounding brackets (<>). Default is “None”

• • • • • • • • • •

Postamble Identical to Preamble (above), but characters are inserted after scanned data. A common postamble would be to insert a “Tab” in lieu of an “Enter” terminator (see page 9). Default is “None”

Scanner Configuration Manager

11

Page 15

Magnetic Reader The Magnetic Stripe Reader configuration parameters differ from the Scanner Port mainly in that magnetic cards adhere to only one standard defined by ANSI and ISO/IEC, while there are over a dozen different symbologies for bar codes. Each magnetic stripe can contain three distinct parallel tracks, each 0.110” (2.794mm) wide. Each track’s unique characteristics are described below.

Track 1 The recording density of Track 1 is defined as 210 bits per inch. The character configuration (encoding) is 6 bits plus 1 parity (odd) bit, which yields 64 unique alphanumeric and symbolic characters. The maximum information content is 79 characters, with the format defined by the Format Code letter: A is defined by the card issuer and is for their exclusive use. B developed by the International Air Transportation Association (IATA) contains alphanumeric information for banking and finance. The standard sequence for format B is listed below. C-M are reserved for use by ANSI Subcommittee X3B10. N-Z are available for use by individual card issuers.

• • • •

Following is track 1 output and an explanation of the components. %B987654321012300^UNITECH/JOE^0512896745280? % B PAN ^ CC NAME ^ DATE SC PVV DD ? LRC % Start Sentinel - 1 character - always “%” for Track 1 Format Code - 1 alphabetical character - in this case, “B” B PAN Primary Account Number - up to 19 digits ^ Separator - 1 character - always “^” for Track 1 CC Country Code - 3 digits (only for MasterCard) NAME Cardholder Name - 2 to 26 alphabetical characters normally last name, then first name, separated by a “/” ^ Separator - 1 character - always “^” for Track 1 DATE Expiration Date - 4 digits - YYMM format SC Service Code - 3 digits - defines transaction requirements PVV PIN Verification Value - 0 to 5 digits DD Discretionary Data - additional characters to fill out maximum record length ? End Sentinel - 1 character - always “?” for all tracks LRC Longitudinal Redundency Check - 1 check character 12

Scanner Configuration Manager

Page 16

Track 2 The recording density of Track 2 is defined as 75 bits per inch. The character configuration (encoding) is 4 bits plus 1 parity (odd) bit, which yields 16 unique characters (10 numeric digits plus 6 symbolic characters :;<=>?). The maximum information content, defined by the American Bankers Association (ABA), is 40 characters arranged in the format below. Following is track 2 output and an explanation of the components. ;987654321012300=05121208967428? ; PAN = CC DATE SC PVV DD ? LRC ; Start Sentinel - 1 character - always “;” for Track 2 PAN Primary Account Number - up to 19 digits = Separator - 1 character - always “=” for Track 2 CC Country Code - 3 digits (only for MasterCard) DATE Expiration Date - 4 digits - YYMM format SC Service Code - 3 digits - defines transaction requirements PVV PIN Verification Value - 0 to 5 digits DD Discretionary Data - additional characters to fill out maximum record length ? End Sentinel - 1 character - always “?” for all tracks LRC Longitudinal Redundency Check - 1 check character

Scanner Configuration Manager

13

Page 17

Track 3 The recording density of Track 3 is defined as 210 bits per inch. The character configuration (encoding) is 4 bits plus 1 parity (odd) bit, which yields 16 unique characters (10 numeric digits plus 6 symbolic characters :;<=>?). The maximum information content, defined by the Thrift Industry (THRIFT-TTS), is 107 characters arranged in the format below. ; FC PAN = CC CuC CE AA AR CB CL RC PINCP IC PANSR FSANSR SSANSR DATE CSN CScN FSAN = SSAN = RM CCD DD ? LRC ; Start Sentinel - 1 character - always “;” for Track 3 FC Format Code - 2 alphabetical characters PAN Primary Account Number - up to 19 digits = Separator - 1 character - always “=” for Track 3 CC Country Code - 3 digits CuC Currency Code - 3 digits CE Currency Exponent - 1 digit AA Amount Authorized Per Cycle - 4 digits AR Amount Remaining This Cycle - 4 digits CB Cycle Begin (Validity Date) - 4 digits - YYMM format CL Cycle Length - 2 digits RC Retry Count - 1 digit - number of remaining PIN tries PINCP PIN Control Parameters - 6 digits IC Interchange Control - 1 digit PANSR PAN Service Restriction - 2 digits - describes the account FSANSR FSAN Service Restriction - 2 digits - see FSAN below SSANSR SSAN Service Restriction - 2 digits - see SSAN below DATE Expiration Date - 4 digits - YYMM format CSN Card Sequence Number - 1 digit CScN Card Security Number - 9 digits FSAN First Subsidiary Account Number - variable number of digits = Separator - 1 character - always “=” for Track 3 SSAN Second Subsidiary Account Number - variable number of digits = Separator - 1 character - always “=” for Track 3 RM Relay Marker - 1 digit CCD Crypto Check - 1 digit DD Discretionary Data - additional characters to fill out maximum record length ? End Sentinel - 1 character - always “?” for all tracks LRC Longitudinal Redundency Check - 1 check character

14

Scanner Configuration Manager

Page 18

Setting Magnetic Reader Parameters Keyboard Configuration Manager, shown left and outlined in detail below, enables the output from the keyboard’s magnetic stripe reader to be modified to the user’s requirements. In a POS environment, normally only Track 2 is selected.

Terminator The Terminator is a command that follows after the bar code data. Four different terminators can be selected here: “Enter”, “Return (on numeric keypad)”, “Field Exit or Right Control”, or “None”. To define a different terminator, use the “Data Editing” function (see page 26) Default is “Enter”.

Send Start/Stop Sentinel Each magnetic stripe track begins with a start character and ends with a stop character (and an LRC character). The start character for track 1 is a % (percent sign), and for tracks 2 and 3 is a ; (semi colon). The stop character for all three tracks is a ? (question mark). Selecting the “No” option for this parameter strips the start/stop sentinels for each track from the output data. Default is “Yes”

Track Selection Select only one, all, or any combination of the available tracks. Selections include: All Tracks Track 1 and Track 2 Track 1 and Track 3 Track 2 and Track 3 Track 1 Output Track 2 Output Track 3 Output Default is “All Tracks”.

• • • • • • •

Scanner Configuration Manager

15

Page 19

Magnetic Reader, continued Track 2 Account Number Only If only track 2 is enabled (see previous page), only the account number from track 2 and the start/stop sentinels are output. If tracks other than track 2 are enabled, this parameter actually outputs all the other track’s data, the account number from track 2, and their start/stop sentinels. Default is “No”.

Output Only When All Tracks Have Correct Data A useful function for insuring data integrity, this function can cause trouble when the card reader tries to read more tracks than are on the card. Default is “No”.

Separator Character Insert one character between each track’s output. Pre-defined characters include: <t>: Tab <n>: Line Feed <d>: Any Digit (not applicable to this function) <a>: Any Letter (not applicable to this function) <*>: Interblock Delay (not applicable to this function) <“>: “ (quotation marks) <dd>: character in hexadecimal notation <<>: < <>>: > The above special characters must be bracketed by < > symbols as shown. Function codes (F keys, Cursor up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu) and must include surrounding brackets (<>). Letters and numbers should be entered directly by keyboard input without surrounding brackets (<>). Default is “None”.

• • • • • • • • •

16

Scanner Configuration Manager

Page 20

Magnetic Reader, continued Track 1 Output Sequence Track 1 output sequence can be easily re-arranged to whatever sequence the user requires. Track 1 parameters include: Account Number Last Name First Name Expiration Year Expiration Month Discretionary Data All Information Delimiter / Text Default is “None”.

• • • • • • • •

Highlight a parameter (such as “Account Number”) in the “Sources Available” area and click on the top horizontal arrow (shown right) to move it to the “Actual Output” area. Use the lower horizontal arrow to remove selections from the Actual Output area. Use the up and down arrows to move selected parameters up or down in relation to the other parameters. When the selected parameters are in the desired sequence, click the “OK” button.

Track 2 Output Sequence Track 2 output sequence is arranged in the same manner as the Track 1 output sequence (above). Track 2 parameters include: Account Number Expiration Year Expiration Month Discretionary Data All Information Delimiter / Text * Note that track 2 does not contain last name and first name data. Default is “None”.

• • • • • •

Scanner Configuration Manager

17