The text of a manual · part 1 of 4
Scanner Configuration Manager User Guide, pages 1 to 10
Pages 1 to 10 of 40
The original document is the PDF (767 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Unitech MS210
Page 1
Scanner Configuration Manager User Guide
(System Requirement: Windows PC)
unitech
Page 2
1.
TABLE OF CONTENTS SCANNER CONFIGURATION MANAGER Start it Up . . . . . . . . . . . . First Look . . . . . . . . . . . . Settings . . . . . . . . . . . . Device . . . . . . . . . . . . . . Beeps and Delays. . . . . . . . . . Beep Tone . . . . . . . . . . . Interblock Delay . . . . . . . . . Intercharacter Delay . . . . . . . Keyboard Wedge . . . . . . . . . . Function Code . . . . . . . . . . Caps-Lock . . . . . . . . . . . Language . . . . . . . . . . . . Wand Emulation Output . . . . . . Level Duration of Minimal Width . . . Polarity of Idle Condition . . . . . . Use Numeric Keypad . . . . . . . RS232 . . . . . . . . . . . . . . Baud Rate . . . . . . . . . . . Parity . . . . . . . . . . . . . Data Bit . . . . . . . . . . . . Handshaking . . . . . . . . . . ACK/NAK . . . . . . . . . . . . BCC Character . . . . . . . . . Time Out . . . . . . . . . . . . Data Direction . . . . . . . . . . Receive Terminator . . . . . . . . Scanner Port . . . . . . . . . . . Terminator . . . . . . . . . . . Use Code ID . . . . . . . . . . Double Verification . . . . . . . . Scanning Mode . . . . . . . . . Label Type . . . . . . . . . . . Aim Function for Long Range Engine . Aiming Time for Long Range Engine . Preamble . . . . . . . . . . . . Postamble . . . . . . . . . . . Magnetic Reader . . . . . . . . . . Track 1. . . . . . . . . . . . . Scanner Configuration Manager
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. 1 . 1 . 3 . 4 . 4 . 4 . 4 . 4 . 4 . 5 . 5 . 5 . 6 . 6 . 6 . 6 . 6 . 7 . 7 . 7 . 7 . 7 . 7 . 7 . 8 . 8 . 8 . 9 . 9 . 9 . 9 . 10 . 10 . 10 . 11 . 11 . 11 . 12 . 12
Page 3
TABLE OF CONTENTS, continued Track 2. . . . . . . . . . . . . . . . . . . Track 3. . . . . . . . . . . . . . . . . . . Setting Magnetic Reader Parameters . . . . . . . Terminator . . . . . . . . . . . . . . . . Send Start/Stop Sentinel . . . . . . . . . . Track Selection . . . . . . . . . . . . . . Track 2 Account Number Only . . . . . . . . Output Only When All Tracks Have Correct Data . Separator Character . . . . . . . . . . . . Track 1 Output Sequence . . . . . . . . . . Track 2 Output Sequence . . . . . . . . . . Bar Code Symbologies . . . . . . . . . . . . . Code 39 . . . . . . . . . . . . . . . . . . I 2 of 5 . . . . . . . . . . . . . . . . . . S 2 of 5 / Toshiba Code . . . . . . . . . . . . Code 32 . . . . . . . . . . . . . . . . . . EAN 128 . . . . . . . . . . . . . . . . . Code 128 . . . . . . . . . . . . . . . . . MSI / Plessey Code . . . . . . . . . . . . . Code 93 . . . . . . . . . . . . . . . . . . Codabar . . . . . . . . . . . . . . . . . . UPC-A . . . . . . . . . . . . . . . . . . UPC-E . . . . . . . . . . . . . . . . . . EAN-13 . . . . . . . . . . . . . . . . . . EAN-8 . . . . . . . . . . . . . . . . . . Code 11 . . . . . . . . . . . . . . . . . . Delta Code . . . . . . . . . . . . . . . . . Supplement Code . . . . . . . . . . . . . . Label Code IV and V . . . . . . . . . . . . . Data Editing . . . . . . . . . . . . . . . . . . Qualifier . . . . . . . . . . . . . . . . . . Modifier . . . . . . . . . . . . . . . . . . Arrange Formulas . . . . . . . . . . . . . . The “Everything Else” Formula . . . . . . . . . Function Codes . . . . . . . . . . . . . . . . ASCII Chart . . . . . . . . . . . . . . . . . . TROUBLESHOOTING . . . . . . . . . . . . . . . Problems and Solutions . . . . . . . . . . . . . BAR CODE TEST CHART . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. 13 . 14 . 15 . 15 . 15 . 15 . 16 . 16 . 16 . 17 . 17 . 18 . 18 . 19 . 19 . 20 . 20 . 20 . 21 . 21 . 22 . 22 . 23 . 23 . 23 . 24 . 24 . 24 . 25 . 26 . 26 . 26 . 28 . 28 . 29 . 30 . 34 . 35 . 36
Scanner Configuration Manager
Page 4
SCANNER CONFIGURATION MANAGER Scanner Configuration Manager software is the simplest and most foolproof way to configure your scanner settings.
Start it Up After loading and starting SCMSetup.exe the icon to the left will appear on your desktop: Click on the SCM icon and the following screen will appear: As you can see, you are presented with a blank work area and a row of icons across the top. Following is an explanation of each of the icons:
Above, from left to right, are the standard Windows icons for “New Document”, Open File”, and “Save File”. Scanner Configuration Manager saves scanner settings in .cfg files, so you can have access to a variety of different scanner configurations that you’ve set up. To reset the scanner back to factory default, click on the “New Document” icon and download the unmanipulated setting to the scanner (see below).
The above icons, from left to right, represent download settings (from computer to scanner), and upload settings (from scanner to computer). The third icon opens a Test Pad where you can view the actual scanner output. Scanner Configuration Manager
1
Page 5
The above four icons are used in the “Data Editing” feature of SCM. From left to right they are the “Add a Formula” icon, the “Remove a Formula” icon, and the right-hand two are the “Move Formula” icons that move selected formulas up or down in relation to each other. For information on data editing, see page 26.
Click this icon to print a series of bar codes that you can scan in order to configure your scanner to the current SCM settings. This option is especially useful if downloading to the scanner is not an option, as in the case of USB, Mac ADB, or RS232 interface, or if Win NT is your operating system. If printing to a PDF file is an option (via Acrobat), this configuration can be sent via e-mail to different locations where they can be scanned from a printed PDF file.
Help is just a click away.
2
Scanner Configuration Manager
Page 6
First Look Click the upload icon (see page 1) and the following pop-up screen will appear: (alternatively, you can click on the “New Document” icon, page 1, in which case the second screen will appear) Enter the scanner product number (MS210, for example). Make sure the “By Keyboard Interface” radio button is selected, and click “OK”. The LED on the top of the scanner will flash during the upload process.
The screen to the left appears. Click on any of the selections under “Current Settings” to view its “Attributes”.
Double-click on any of the “Attributes” to edit that attribute. This is done via a drop-down menu. After selecting your configuration settings, click on the Download icon (see page 1). The LED on the top of the scanner will flash during the download process. Afterwards, you will be prompted to do an optional “Quick Test”. Scanner Configuration Manager
3
Page 7
Settings Following is a detailed discussion of each of the settings, their attributes, and the effects each of these will have on data output from your Unitech scanner.
Device The only attribute for the “Device” setting is “Device ID”, which defines the device to which the scanner is connected (usually a computer or terminal). Select the setting that most closely describes your device. The default selection is “01 - IBM PC/AT, PS/2 MOD 40, 60, 80, USB”, which is appropriate for most PCs.
Beeps and Delays The three attributes for “Beeps and Delays” are: “Beep Tone”, “Intercharacter Delay”, and “Interblock Delay”.
Beep Tone Select a value from “None” to “High” to set the loudness of the tone, or select “Low to High” or “High to Low” to set the characteristic of the tone. Default is “Medium”.
Interblock Delay Interblock delay is the time duration that can be inserted between one block of data and another. This function is analogous to the time duration required between dialing a phone number’s country code and the phone number itself. The interblock delay can be inserted via SCM’s Data Editing function (see page 26). Default is “10 ms”.
Intercharacter Delay Intercharacter Delay is the time duration between data characters sent from the scanner to the computer. Intercharacter delay is usually inserted when the data flow must be slowed down for the benefit of a slower computer. Default is “1 ms”. 4
Scanner Configuration Manager
Page 8
Keyboard Wedge Your Unitech keyboard contains a built in data decoder or “wedge” that translates raw bar code input into Keyboard Scan Code, with the result that bar code data exits the scanner as if you had typed the text. Seven keyboard wedge parameters are listed below:
Function Code Function Code determines how function code characters from the scanner is output. If Yes is selected, then scanned function codes will output the same as if their corresponding function keys were pressed. Scanning an F1 label will pop-up a “Help” box, F3 a “Find” pop-up box, etc. If No is selected, the scanned function codes will output special character strings defined by Unitech for non-print character output. Default is “Yes”.
• •
Caps-Lock The Caps Lock function determines how the Caps Lock key controls the case of alphabetical characters. The three options below are available: Auto Trace automatically determines the Caps Lock key status and informs the decoder accordingly. Lower Case manually coordinates the physical state of the Caps Lock key with the Caps Lock state of the decoder. For example, if the Caps Lock light is not on, then “Lower Case” should be selected. Upper Case is the same as Lower Case (above) except that it applies to the upper case state. If the Caps Lock is on, then Upper Case should be selected. Default is “Auto Trace”.
• • •
Scanner Configuration Manager
5
Page 9
Keyboard Wedge, continued Language Your Unitech scanner can output characters using eleven different language sets, including: Danish French Norwegian Swiss U.S. English German Swedish Alt Key Mode U.K. English Italian Spanish Default is “U.S.”
Wand Emulation Output Wand emulation refers to raw, undecoded bar code data - 0s and 1s. The choice here is whether to assign a 1 (high) to the dark bar and a 0 (low) to the white space - or vice-versa. Bar with High / Space with Low Bar with Low / Space with High Default is “Bar with High / Space with Low”.
Level Duration of Minimal Width This adjustment refers to the amount of time the wand scanner requires to recognize an individual bar in a bar code. The choices are 200 µs (microseconds) or 600 µs. Default is “200 µs”.
Polarity of Idle Condition The polarity of the idle condition (while it has no input) of the wand scanner can be either high or low. Default is “Low”.
Use Numeric Keypad The ASCII code for numeric input from the keypad part of the keyboard is different from that of the upper row of the keyboard proper. Some accounting programs require keypad input, and for that reason, the keyboard decoder can output scanned or read numbers as either keypad or keyboard (upper row) output. Default is “No”.
6
Scanner Configuration Manager
Page 10
RS232 Baud Rate Baud Rate (bits per second) refers to the speed of the data through the RS232 port. If the data error rate is unacceptably high, setting the baud rate lower should help. Default is “9600 Baud”.
Parity A technique used to detect data transmission errors by adding an extra bit to each character. This scheme has been supplanted in modern communication devices by “error correction”. Default (and the current universal standard) is “No Parity”.
Data Bit Number of bits per byte that are dedicated to data (minus start/stop bits). Default (and the current universal standard) is “8 Data Bits”.
Handshaking Handshaking is the mechanism that controls the speed of data flow so that a slower receiver of data is not overwhelmed by a faster sender of data. Selections are: “Ignore”, “RTS (request to send) Enabled at Power Up”, and “RTS Enabled in Communication”. Default is “Ignore”
ACK/NAK Data characters that are sent from the receiver to the sender in order to “acknowlege” or “not acknowlege” the receipt of the data without error. Rarely used these days. Default is “No”.
BCC Character Block Check Character. An error checking character added for data integrity. Default is “No”. Scanner Configuration Manager
7