Page 28
Data Editing, continued Arrange Formulas After the formulas have been created, they must be arranged in the optimum sequence by selecting formulas and using the “Move Formula” icons (see page 4) This sequence is usually according to their qualifier - from least likely to occur to most likely to occur. In the example pictured above, a series of formulas are designed to output all the data in a bar code that follows a series of “0”s. For instance, if the actual bar code is “000045678”, the desired output would be “45678” (the original minus all the 0s occurring at the beginning of the string). If there are six 0s (Formula 1), then the output starts at the seventh position. If there are five 0s (Formula 2), then the output starts at the sixth position, etc. If, instead, we were to place the qualifier for two 0s above (before) the qualifier for six 0s, then the formula stipulating two 0s would activate even if there were six 0s in the bar code because the qualifier would stop looking for 0s after it had found two. In this case, all qualifiers with three or more 0s would be disregarded, which would not be a desirable result.
The “Everything Else” Formula If a formula is entered into the Data Editing area, then all scanned bar codes will be evaluated according to this formula. If the scanned bar code does not satisfy the requirements of the Qualifier (see page 22), then no data is output. Practically speaking, the scanner has been set up to scan only bar codes that are defined by the Qualifier. You will not be able to scan other types of bar codes. The answer to this problem is to end the sequence of formulas with a formula that has no Qualifier and whose Modifier includes all the scanned data (starts at position 1 and outputs “all remaining”). An example of this can be seen as Formula 7 above. 24
MS146 Manual
Page 29
Function Codes for PC (Code 39) (Characters in parentheses represent Code 39 bar code printing)
F1 (%VA)
F2 (%VB)
F3 (%VC)
F4 (%VD)
F5 (%VE)
F6 (%VF)
F7 (%VG)
F8 (%VH)
F9 (%VI)
F10 (%VJ)
F11 (%VK)
F12 (%VL)
Esc (/FK)
Cursor Up (/FE)
Delete (/FX)
Tab (/FI)
Cursor Down (/FF)
Left Enter (/FL)
Back Tab (/FJ)
Cursor Left (/FD)
Right Enter (/FM)
Shift Make (/FP)
Cursor Right (/FC)
Page Up (/FG)
Shift Break (/FS)
Insert (/FW)
Page Down (/FH)
Ctrl Make (/FQ)
Alt Make (/FR)
Right Ctrl (/FO)
Ctrl Break (/FT)
Alt Break (/FU)
MS146 Manual
25
Page 30
ASCII Chart (Characters in parentheses represent Code 39 bar code printing)
NUL (%U)
VT ($K)
SYN ($V)
SOH ($A)
FF ($L)
ETB ($W)
STX ($B)
CR ($M)
CAN ($X)
ETX ($C)
SO ($N)
EM ($Y)
EOT ($D)
SI ($O)
SUB ($Z)
ENQ ($E)
DLE ($P)
Escape (%A)
ACK ($F)
DC1 ($Q)
FS (%B)
BEL ($G)
DC2 ($R)
GS (%C)
BS ($H)
DC3 ($S)
RS (%D)
Tab (%I)
DC4 ($T)
US (%E)
LF ($J)
NAK ($U)
Space
26
MS146 Manual
Page 31
ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)
! (/A)
, (/L)
7
" (/B)
-
8
# (/C)
.
9
$
/
: (/Z)
%
0
; (%F)
& (/F)
1
< (%G)
` (/G)
2
= (%H)
( (/H)
3
> (%I)
) (/I)
4
? (%J)
* (/J)
5
@ (%V)
+
6
MS146 Manual
27
Page 32
ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)
28
A
L
W
B
M
X
C
N
Y
D
O
Z
E
P
[ (%K)
F
Q
\ (%L)
G
R
] (%M)
H
S
^ (%N)
I
T
_ (%O)
J
U
' (%W)
K
V
MS146 Manual
Page 33
ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)
a (+A)
l (+L)
w (+W)
b (+B)
m (+M)
x (+X)
c (+C)
n (+N)
y (+Y)
d (+D)
o (+O)
z (+Z)
e (+E)
p (+P)
{ (%P)
f (+F)
q (+Q)
| (%Q)
g (+G)
r (+R)
} (%R)
h (+H)
s (+S)
~ (%S)
i (+I)
t (+T)
Delete (%T)
j (+J)
u (+U)
k (+K)
v (+V)
MS146 Manual
29
Page 34
SPECIFICATIONS PERFORMANCE Light Source:
Visible Light: 660nm LED Infrared Light: 930nm LED
Depth of field: Sensor: Resolution: Print Contrast: Scan rate:
2mm Photo diode 6 mils (.015mm) min. 0.6 min. 2” (50mm) to 30” (750mm) per second
DECODER Symbologies:
Codabar, Code 11, Code 32, Code 39 (Standard and Full ASCII), Code 93, Code 128, Delta Code, EAN-8, EAN-13, Label Code IV and V, MSI Code, Plessey Code, Standard 2 of 5, UPC-A, UPC-E
Interfaces:
PS/2, RS232, TTL, USB (see next page for pinouts)
Configuration:
Via Scanner Configuration Manager software (downloadable from www.ute.com)
Data Editing:
Almost unlimited (via Scanner Configuration Manager software - see above)
MECHANICAL / ELECTRICAL Dimensions: Weight: Max Card Thickness: Scanning Area: Voltage: Power consumption:
3.75” L x 1.375” W x 1.1875” H (95mm L x 35mm W x 30mm H) 6.7 oz. (190 grams) with cable 54 mils (.054”, 1.37mm) 0.43” (11mm) from bottom of card 5 Volts DC Decoded: 70mA TTL (Undecoded): 35mA
Cord:
6’ 0” (1.83m)
ENVIRONMENTAL Temperature: Humidity: Mechanical shock:
30
Operating:
32° to 122° F (0° to 50° C)
Storage:
-4° to 140° F (-20° to 60° C)
0% to 95% RH non-condensing 5 foot (1.5m) drop to concrete
MS146 Manual
Page 35
PINOUTS Keyboard Interface (6 pin mini-DIN male) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
Data (Connect to PC Data) Reset (Connect to PC Reset) Ground +5V DC Input Clock (Connect to PC Clock) N/C
RS232 Interface (DB9 female) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9
N/C TXD (Transmit Data) RXD (Receive Data) N/C GND (Ground) N/C CTS (Clear to Send) RTS (Request to Send) VCC (+5V DC Input)
TTL (Wand) Interface (DB9 female - squeeze release) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9
N/C Data N/C N/C N/C N/C Ground N/C +5V DC Input
2
1
4
3 6
5
5 4 3 2 1
9 8 7 6
5 4 3 2 1
9 8 7 6
USB Interface (4 pin male) Pin 1 Pin 2 Pin 3 Pin 4
MS146 Manual
+5V DC Input Data Data + Ground
1 2 3 4
31
Page 36
TROUBLESHOOTING Most problems that you might encounter with your scanner can be solved using the following procedures:
Try scanning other bar codes. If your scanner can scan other types of bar code symbologies, but cannot scan your bar codes, first check to see if your particular bar code symbology is enabled. If it is, try the scanner on the same bar code type in the Bar Code Test Chart in the back of this manual. Then, insure that your bar codes are crisp and clear.
Reset to Factory Default. While the Scanner Configuration Manager program is active, click the “new file” icon (see page 3) and the “download to scanner” icon (see page 3) to reset your scanner back to factory default. Please note that the factory default interface is specified as PS2/ AT/USB. If you have a different interface, then you will need to configure that also (see page 6) and then download to the scanner. Caution: This procedure will erase special configurations that you would have created.
Test the scanner on other ports. Unitech scanners are built to the highest standards, and a perceived scanner malfunction may actually be a malfunction in the host computer. Test the scanner on the host’s other ports if possible or, in necessary, on other systems to verify that the problem is actually in the scanner and not in the host computer.
32
MS146 Manual