Bar Code Symbologies, continued Interleaved 2 of 5

• Enabled toggles the ability for the keyboard/scanner to read I 2 of 5 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for I 2 of 5, which • • • • • is referred to in the “Use Code ID” function (see page 11). Default is letter “I”. Fix Length (by first 3 reads) fixes the length of acceptable subsequent bar code reads from the first three bar codes read. Useful as a data verification if all bar codes are of a consistent length. Default is “No”. Check Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”. Suppress Digit suppresses the output of the first or last bar code digit. Default is “Not Suppressed”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “10”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “64”.

Standard 2 of 5 / Toshiba Code (China Postal Code)

• Enabled toggles the ability for the keyboard/scanner to read S 2 of 5 / Toshiba Code on or off. Default is “No”. • S25 Code ID is a user-definable identification letter for S 2 of 5, • • • • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “H”. Toshiba Code ID is the same as S25 Code ID (above), but instead applicable to Toshiba Code. Default is letter “C”. Fix Length (by first 3 reads) fixes the length of acceptable subsequent bar code reads from the first three bar codes read. Useful as a data verification if all bar codes are of a consistent length. Default is “No”. Check Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “4”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

MS146 Manual

15

Page 20

Bar Code Symbologies, continued Code 32

• Enabled toggles the ability for the keyboard/scanner to read Code 32 on or off. Default is “No”. • Code ID is a user-definable identification letter for Code 32, • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “T”. Send Leading Character toggles sending or not sending a leading (“start bar code”) character. Default is “Send”. Send Tailing Character toggles sending or not sending a tailing (“stop bar code”) character. Default is “Send”.

EAN 128

• Enabled toggles the ability for the keyboard/scanner to read EAN 128 on or off. Default is “No”. • Code ID is a user-definable identification letter for EAN 128, • • which is referred to in the “Use Code ID” function (see page 11). Default is “None”. Enable Code ID determines whether or not to assign a Code ID. Default is “No”. Field Separator is a user-definable character to insert between fields. Default is “None”.

Code 128

• Enabled toggles the ability for the keyboard/scanner to read Code 128 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for Code 128, • •

16 which is referred to in the “Use Code ID” function (see page 11). Default is letter “K”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “64”.

MS146 Manual

Page 21

Bar Code Symbologies, continued MSI / Plessey Code

• Enabled toggles the ability for the keyboard/scanner to read MSI / Plessey Code on or off. Default is “Yes”. • MSI Code ID is a user-definable identification letter for MSI • • • • •

Code, which is referred to in the “Use Code ID” function (see page 11). Default is letter “O”. Plessey Code ID is the same as MSI Code ID (above), but instead applicable to Plessey Code. Default is the letter “P”. Send Check Digit toggles whether or not to send a check digit. Default is “No Send”. Check Digit Formula defines the formula to calculate the check digit. Options are: “Double Module 10”, Module 11 Plus 10”, and “Single Module 10”. Default is “Double Module 10”. Minimum Length defines the minimal length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “16”.

Code 93

• Enabled toggles the ability for the keyboard/scanner to read Code 93 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for Code 93, • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “L”. Minimum Length defines the minimal length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

MS146 Manual

17

Page 22

Bar Code Symbologies, continued Codabar

• Enabled toggles the ability for the keyboard/scanner to read Codabar on or off. Default is “No”. • Code ID is a user-definable identification letter for Codabar, • • • • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “N”. Send Start/Stop toggles sending or not sending start/stop sentinels. Default is “No Send”. Check Digit defines whether or not a check digit (to insure data accuracy) is calculated, and if so, whether it should be sent or not. Default is “Not Calculate”. CLSI Format deletes the start and stop sentinels and outputs the data with spaces inserted after the 1st, 5th, and 10th characters. Default is “No”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “3”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

UPC-A

• Enabled toggles the ability for the keyboard/scanner to read UPC-A on or off. Default is “Yes”. • Code ID is a user-definable identification letter for UPC-A, which • •

18 is referred to in the “Use Code ID” function (see page 11). Default is letter “A”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

MS146 Manual

Page 23

Bar Code Symbologies, continued UPC-E

• Enabled toggles the ability for the keyboard/scanner to read UPC-E on or off. Default is “Yes”. • Code ID is a user-definable identification letter for UPC-E, which • • • • is referred to in the “Use Code ID” function (see page 11). Default is letter “E”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “No Send”. Zero Expansion adds 0s to the bar code output to change the output format to UPC-A. Default is “No”. Enable NSC=1 allows the output of a UPC-E bar code with a first digit of “1”. Default is “No”.

EAN-13

• Enabled toggles the ability for the keyboard/scanner to read EAN-13 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for EAN-13, which • • • is referred to in the “Use Code ID” function (see page 11). Default is letter “F”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”. Bookland EAN toggles whether or not to send the EAN-13 bar code data in Bookland EAN (ISBN) format. Default is “No”.

EAN-8

• Enabled toggles the ability for the keyboard/scanner to read EAN-8 on or off. Default is “Yes”. • Code ID is a user-definable identification letter for EAN-8, which • • is referred to in the “Use Code ID” function (see page 11). Default is letters “FF”. Send Leading Digit toggles sending or not sending a leading (“start bar code”) digit. Default is “Send”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

MS146 Manual

19

Page 24

Bar Code Symbologies, continued Code 11

• Enabled toggles the ability for the keyboard/scanner to read Code 11 on or off. Default is “No”. • Code ID is a user-definable identification letter for Code 11, • • • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “J”. Check Digit Number defines the check digit correct result to be either “1” or “2”. Default is “2”. Send Check Digit toggles whether or not to send a check digit. Default is “No Send”. Minimum Length defines the minimum length the user will accept for a valid bar code. Default is “1”. Maximum Length defines the maximum length the user will accept for a valid bar code. Default is “48”.

Delta Code

• Enabled toggles the ability for the keyboard/scanner to read Delta Code on or off. Default is “No”. • Code ID is a user-definable identification letter for Delta Code, • • which is referred to in the “Use Code ID” function (see page 11). Default is letter “D”. Calculate Check Digit toggles whether or not to calculate a check digit. Default is “Yes”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

Supplement Code (for UPC-E, ISBN, EAN-13)

• Two Supplement Code toggles whether the two digit supplemental bar code is to be recognized. Default is “No”. • Five Supplement Code toggles whether the five digit supplemental bar code is to be recognized. Default is “No”. • Must Present toggles whether or not the supplemental bar code must be present in order to output data. Default is “Yes”. • Insert Space Separator toggles whether or not to output a space between the main and supplemental bar codes. Default is “No”.

20

MS146 Manual

Page 25

Bar Code Symbologies, continued Label Code IV and V

• Enabled toggles the ability for the keyboard/scanner to read Label Code IV and V on or off. Default is “No”. • Code ID is a user-definable identification letter for Code IV and V, • which is referred to in the “Use Code ID” function (see page 11). Default is letter “B”. Send Check Digit toggles whether or not to send a check digit. Default is “Send”.

MS146 Manual

21

Page 26

Data Editing Data Editing is a powerful function that can give you tremendous control over how data is exported from the scanner. After clicking on “Data Editing” the data editing icons become active. Click on the icon with the blue circle and white plus sign. The “Define Formula” pop-up box to the right appears, which is divided into two sections: “Qualifier” and “Modifier”.

Qualifier The Qualifier section defines the conditions that must be present for the bar code to be modified, such as what type of bar code it must be (Code 39, EAN-13, etc.), what length the bar code must be, or what characters (defined by a match string) the bar code must contain. When the conditions of the Qualifier are met, the bar code is then modified according to the rules defined in the “Modifier”, below.

Modifier The Modifier section contains three selections: “From Original”, “Add New”, and “Delete”. From Original extracts the desired data from the existing bar code. The Start Parameter defines the beginning of the string of data that is to be output. The start parameter can either be defined by position starting from the beginning (“From Position”), or a specific number of characters from the end of the string (“From Last Position”), or a specified number of characters before or after a user-defined character string (“After Matching”). The End Parameter defines the end of the string of data that is to be output. Three options are available: “Number Of Characters To Output”, “All Remaining”, and “After Matching”. The first two are self-explanatory. “After Matching” defines the end as a specified number of characters before or after a user-defined character string. 22

MS146 Manual

Page 27

Data Editing, continued Even if the original bar code data is not modified, if additional characters are to be added (see “Add New”, below) the original Start Parameter must be defined as From Position “1” and the End Parameter defined as “All Remaining”, otherwise, none of the original data will be output.

Add New adds characters (printing and nonprinting) to the data output from the scanner/ reader. These characters can be added before and/or after the actual scanned data (see “Move Up / Move Down”, below). Pre-defined characters include: <t>: Tab <r>: Carriage Return <n>: Line Feed <d>: Any Digit (data editing) <a>: Any Letter (data editing) <*>: Interblock Delay (data editing) <“>: “ (quotation marks) <dd>: character in hexadecimal notation <<>: < (less than) <>>: > (greater than) Characters must be bracketed by < > symbols. Letters and numbers should be represented in hexadecimal format (accessable in a linked menu). For instance, the lower-case letter “t” should be entered as <74> and the numeral 5 should be entered as <35>. Function codes (F keys, Cursor up, Enter, etc.) can also be inserted via hexadecimal code (accessable in a linked menu).

• • • • • • • • • •

Delete deletes existing modifier strings. Move Up / Move Down moves the modifiers up and down in relation to each other. The top modifier will be performed first and each one down the list will be performed in sequence. The original data (modified or unmodified) will be output according to its position in the modifier sequence.

MS146 Manual

23