Page 21
Chapter 2 Using the Hardware
AutoLF Use the [ ] key to toggle between ON or OFF, then hit ENTER to make the selection. When AutoLF is set to ON, the HT580 will append a LF (10 hex) character to the input data block. Mode Use the [ ] key to toggle between BLOCK and CHAR, then hit ENTER to make the selection. Line/Page Use the [ ] key to toggle among LINE, PAGE and BOTH, then hit ENTER to make the selection.
FormCaching < FORM > FormCaching is a built-in application generator on the HT580 which allows users to create a data entry application from the device by specifying field prompt, field length, data type, input method, delimiter, etc, without writing a program and loading it to the HT580. Entry data can be processed in batch mode or 2 real time modes. Batch mode
Stores your data (according to your settings) into “FORM.DAT”. The user can use the communication program to get this file from the device to a PC.
On line None
Directly sends the record data via RS232/USB or Bluetooth (according to your port settings) after recording your data. Data will still be stored into “FORM.DAT.”
On line Multi
Follows Unitech’s Multi-protocol. Data will be stored in the system area and wait for a remote polling command.
To provide a convenient way to distribute Formcaching settings, users are able to import and export FormCaching settings from one HT580 to another.
22
Page 22
Chapter 2 Using the Hardware
When in setting mode, there are 3 options – SETTING, IMPORT and EXPORT as shown in menu below. 1. SETTING 2. IMPORT 3. EXPORT
EXPORT IMPORT SETTING
Saves FormCaching’s configuration as “FORM.SET”. Changes FormCaching configuration from the “FORM.SET” file. Configures FormCaching‘s operation flow.
When SETTING is selected, the HT580 will first ask the user to specify data fields in four categories, including field prompt, data length, data type and device type. After defining all of the data field options, use the ESC key to end the setup. Below is a table describing all of the FormCaching Setting options. FormCaching Specification DATA FIELD DEFINITION: maximum field number= 8 Category Range FIELD PROMPT Max.16 characters 1-48 MIN/MAX Field LENGTH Field type 1.NUMERIC 2.ALPHANUM
DEVICE TYPE
1.KEY ONLY 2.SCAN ONLY 3.BOTH
Description set field prompting Set minimum and maximum field length Numeric data (0~9) or alphanumeric data (20H~FCH) Input by keyboard only, bar code scanning only or both
23
Page 23
Chapter 2 Using the Hardware
DATA RECORD DEFINITION Category Range Between Field 1. Append Screen 2. Clear Screen
FIELD DELIMITER
1. , 2. ; 3. SPACE 4. TAB 5. FIXED LENGTH
RECORD DELIMITER
1. CR 2. LF 3. CRLF 1. NONE 2. MMDD 3. YYYYMMDD 4. DDMMYY 5. YYYYMMDD 6. DDMMYYYY 1. NONE 2. HHMM 3. HHMMSS 4. SSMMHH 1. Batch 2. Online None 3. Online Multi 0-6
DATE STAMP FIELD
TIME STAMP FIELD
Trans Mode
FIELD DELAY
Description 1. Append Screen: Prompt will be displayed on next line according to previous cursor place. If cursor is already on the last line, it will scroll one line up. 2. Clear Screen: It will clear screen and then display Assign field delimiter, “Fixed Length” mean to store data according to maxi length setting, it will automatically append spaces to end of field data if length of input data are less than maxi. length Assign record delimiter
Assign date stamp and specify the format of date stamp
Assign time stamp and specify the format of time stamp
Defines the way your data is stored Specify time delay between each record input in second
24
Page 24
Chapter 2 Using the Hardware
When FormCaching is enabled, a data file named FORM.DAT will be created in the HT580. FORM.DAT stores the data as entered by the user when using the FormCaching program. The HT580 will not allow the user to redefine the data fields in FormCaching once the FORM.DAT has been created. The file FORM.DAT must be deleted in order to implement any change in the configuration of FormCaching. Running FormCaching The HT580 built-in application FormCaching can be run from the main menu by selecting the terminal option, then selecting 2. Formcaching. The FormCaching application will follow the prompt settings previously defined by the user to request input, and stores the data in the FORM.DAT file. HT580 FormCaching Defaults The HT580 enables FormCaching with the default settings: DATA FIELD DEFINITION: Field number=2 Category Field #1 FIELD PROMPT DATA LENGTH FIELD TYPE DEVICE TYPE Field #2 FIELD PROMPT DATA LENGTH DATA TYPE DATA RECORD DEFINITION Category FIELD DELIMITER RECORD DELIMITER DATE STAMP FIELD TIME STAMP FIELD FIELD DELAY
Setting ITEM: 20 ALPHANUM BOTH QTY: 8 ALPHANUM Setting , CR NONE NONE 1
25
Page 25
Chapter 2 Using the Hardware
Power < PWR > The unit will automatically power off if nothing is scanned or keyed after the set amount of time. Use the MENU key to set the auto-off time-out to 1, 2, 5, 10, or 15 minutes, select DISABLE to disable the auto power-off
Password <PSWD> The Password Setting allows the user to change the default password. The default password is “580”
Barcode < BAR > This option is used to configure individual barcode symbologies. After entering the configuration menu, the LCD will display the BARCODE Setup as shown below. <BARCODE SETUP> CODE 39 ON
Setup decoding of HT580 supported bar code symbologies: Symbology Code 39
I 2 of 5
Code 32
Function Decoding full ASCII Check Digit Start/stop Character Decoding Check Digit First digit Last digit Decoding First digit Last digit
Option ON/OFF ON/OFF ON/OFF Send/No-send ON/OFF ON/OFF SEND/NOT SEND SEND/NOT SEND ON/OFF SEND/NOT SEND SEND/NOT SEND
Default ON OFF OFF NO SEND ON OFF SEND SEND ON SEND SEND 26
Page 26
Chapter 2 Using the Hardware
Symbology Matrix 2 of 5
Function Decoding Check Digit Industrial 2 of 5 Decoding Codabar Decoding Check Digit CHINA POST
MSI
IATA 2 of 5 CODE 11 EAN-13
EAN-8
UPC-A
Option Default ON/OFF ON ON/OFF OFF ON/OFF ON ON/OFF ON ON / ON&Not Send / ON & SEND / OFF OFF ON/OFF ON Decoding Check Digit ON / ON&Not Send / ON & SEND / OFF OFF ON/OFF OFF Decoding CHECK DIGIT SINGLE MOD 10/DOUBLE MOD 10/ SINGLE MOD DOUBLE MOD 11+10 MOD 10 ON & Send / ON & NOT SEND OFF Check Digit ON/OFF OFF Decoding Check Digit ON / ON &Not Send / ON&SEND / OFF OFF ON/OFF OFF Decoding Check Digit ON / ON&Not Send / ON&SEND / OFF OFF ON/OFF ON Decoding ISBN ON/OFF OFF ISBN ON/OFF OFF Send Leading Digit Send/No-send Send/No-send Send Check Digit ON/OFF ON Decoding Leading Digit SEND/NOT SEND Send SEND/NOT SEND Send Check Digit ON/OFF ON Decoding EXPEND to ON/OFF OFF EAN-13 Send Leading Digit ON/OFF ON/OFF Send Check Digit
27
Page 27
Chapter 2 Using the Hardware
Symbology UPC-E
Function Decoding UPC-E0 UPC-E1 EXPEND TO UPC-A Leading Digit Check Digit CODE 93 Decoding Code 128 Decoding EAN128 EAN128 CODE ID EAN128 FUNC CH Telepen Decoding UK PLESSEY Decoding Check Digit
Option ON/OFF ON/OFF ON/OFF ON/OFF
Default ON ON ON OFF
SEND/NOT SEND SEND/NOT SEND ON/OFF ON/OFF ON/OFF ON/OFF
Send Send OFF ON ON OFF
NOT SEND/SEND
NOT SEND
ON/OFF ON/OFF SEND/NOT SEND
ON OFF Send
28
Page 28
Chapter 2 Using the Hardware
Diagnostic <Diag> The HT580 has a built-in diagnostics program to test the terminal’s hardware. The test routines are data destructive. Therefore, before running the diagnostic program, make sure you back up the data on the HT580. NOTE: When a hardware or software service has been made on the HT850, such as maintenance, repair or upgrade, it is strongly recommended to run the diagnostic program. 1. VER 3. LCD 5. PWR 7. RTC
ITEM VER SCAN LCD COMM PWR KEY RTC MEM
2. SCAN 4. COMM 6. KEY 8. MEM
DESCRIPTION Display firmware version for the HT580 and Decoder. Tests barcode input by scanning barcode labels. Press the ESC key to return to the diagnostics menu. Darken the dots of the LCD screen and cycle power to the LCD backlight to check if the LCD functions OK Connect to the PC’s communication testing program to test the USB/ RS232 communication Tests Battery power Tests every key response Current time/date is displayed Tests RAM condition
29
Page 29
Chapter 2 Using the Hardware
System <SYS> There are 4 options given in the System menu as shown below – Warm Start, Cold Start, Update F/W and Update Decoder. 1. WARM START 2. COLD START 3. UPDATE F/W 4. UPDATE DEC
Warm Start Cold Start
Warm boots the HT580 Reboots the HT580, erasing all data and returning all configurations to default. Update Firmware Update firmware. (See page 38) Update Dec
Unit must be sent in to Unitech for this update.
Another way to Cold/Warm start HT580 by combination keys: COLD START: While the unit is OFF. Press and hold the CMD/ALPHA keys and press the POWER key simultaneously. WARM START: While the unit is OFF. Press and hold the ALPHA key and press the POWER key simultaneously.
FormCaching After configuring the Formcaching you can press “2” from the main menu to enter Formcaching’s data input. Input data will be stored on the HT580 as the file “Form.dat”. You can use the communication tool to upload it back to PC. You can delete it from the HT580 after it has been successfully uploaded to PC.
30
Page 30
Chapter 3 Communication USB Communication To connect the HT580 to PC via USB, you need to install the USB driver which will redirect data to a virtual COM port. You can get the USB driver from HT580 CD. Windows will prompt with the new device dialog box when the HT580 is first connected to the PC via USB. Please direct the dialogue box to the Unitech USB driver folder and then follow its prompting to install the driver. Then, check for the correct COM port number from Control Panel System Hardware Device manager. Then you can find correct COM number from “USB Serial Port” under option “Connection Port (COM and LPT)” In the HT580, you should change the default communication port to “RS232/USB” from Setting Supervisor COMM