Page 11

Chapter 1 Getting Started

Communication Cradle The HT580’s battery can be charged by placing the HT580 into its charging/communication cradle - part number: 5000-601558 (RS232-USB) / 5000-601557 (Modem) Positioning Terminal Into Cradle 1. Figure A - Proper Position

Figure A shows the proper way to insert your terminal while using the cradle to transmit data or to charge. Please note that the connector in the bottom of the cradle may be damaged if you use excessive force to insert the terminal.

Front View

2. Figure B - Improper Position

Figure B shows the improper way to insert the terminal into the cradle. Do not insert the terminal into the cradle incorrectly. It will not function properly and damage can occur.

Back View

12

Page 12

Chapter 1 Getting Started

Communication Cradle LED Icons This LED light (Red) shows the power status of the cradle itself. An Illuminated light indicates the cradle is charging. To identify if the terminal is fully charged, it may be necessary to check the terminal LCD. This LED light (Green) shows transmission status of the cradle itself. An illuminated light indicates that data is in transmission.

HT580 Communication with the Host

USB client 1.1 connection through cable

RS232/Modem Cradle Communication

Interface Port The HT580 communicates via the RS232 communication port located on the bottom of the unit. You can connect the HT580 directly via the communication cable to your PC’s RS232 port for data transfer, or connect via the cradle.

Pin Assignment Pin

Name

Pin

Name

1

US-POWER

7

DSR

2

GND

8

GND

3

DC-IN

9

DTR

4

USB DP

10

TXD

5

CTS

11

RXD

6

RTS

12

USB DP

13

Page 13

Chapter 2 Using the Hardware HT580 Keypad The HT580 keypad consists of 18 rubber keys and one power key. The keypad is configured into three different modes: Numeric mode, Command mode, and Alphabetic mode. The keypad is configured in Numeric mode by default, Command mode when the light green CMD key is selected, or Alphabetic mode when the blue ALPHA key is selected.

Keypad Description ESC MENU SCAN C ENTER

To power on the unit press the power key located on the top right cover of the device. Returns you back to the previous menu. Press MENU to scroll items you require. Press SCAN to trigger scanning function or to perform as the ENTER key while in Setting mode. Press C to delete. Press ENTER to save changes or to go to the next page.

ALPHA

Press ALPHA to switch to Alphabet. Any alphabetical character (in blue print) can be activated with the ALPHA key

CMD

Press CMD to perform delimiters such as “#”, “$”, etc. Any delimiter (printed in green) can be activated with the CMD key.

14

Page 14

Chapter 2 Using the Hardware

Barcode Scanning Spectrum

Operating the HT580 After powering on the HT580, you will see the Main Menu as below: HT580 V1.15 1. SETTING 2. TERMINAL 3. RUN EASYJOB

There are 3 options: Setting, Terminal, and Run EasyJob. NOTE: The 3rd option “3. RUN EASYJOB” will only be displayed if the device contains an EasyJob Program. Please refer to the EasyJob Manual for more information.

15

Page 15

Chapter 2 Using the Hardware

Setting the Date/Time Setting System The Setting menu does 2 major functions – User Mode settings and Supervisor settings. Since barcode scanning is disabled in menu mode, the SCAN key is used as the ENTER key. While on Setting mode, the user can use the following two ways to select any item. • Press the MENU key to move to the target item and then press the SCAN/ENTER key • Directly press the item number associated with the setting, to enter the setting options After selecting the Setting menu from the main screen, there are four setting options: 1. DATE & TIME 2. DEVICE 3. MODEM 4. SUPERVISOR

DATE & TIME The Date & Time page will appear as it is shown below: YYYY-MM-DD 2000-01-08 HH-MM-DD 05:50:35

Press numeric keys to input correct date and time. Once complete, press ENTER to save the revised settings. To return to the previous menu, press ESC.

16

Page 16

Chapter 2 Using the Hardware

Device Settings Device settings are the HT580’s basic settings as shown in menu below. 1. BACKLIGHT 2. SCANNER 3. AUTORUN 4. MEM 5. BUZZER 6. KEY

Backlight The HT580’s backlight can be turned on automatically after a key is pressed, and it will automatically turn off after predefined period time if no keys are pressed. The time-out period will be reset if any keys are pressed. In the HT580, the time-out period can be set to 10, 20, 30 or 60 seconds. The backlight can also be set to always off, or always on. Use the MENU button to adjust setting. Below are the options you may choose. ITEM ON 10 SECS ON 20 SECS ON 30 SECS ON 60 SECS Always Off

DESCRIPTION The backlight turns on after pressing a key, and turns off automatically after 10 seconds The backlight turns on after pressing a key, and turns off automatically after 20 seconds The backlight turns on after pressing a key, and turns off automatically after 30 seconds The backlight turns on after pressing a key, and turns off automatically after 60 seconds Backlight always stays on Backlight always stays off

17

Page 17

Chapter 2 Using the Hardware

Scanner Scanner selection changes the way your barcode scanner acts. Below are the possible modes of operation, and explanations of what they do. ON NORMAL

ON FLASH

OFF

Default operating mode. (One trigger, one scan). The scanning beam will be emitted when the SCAN key is pressed, and the scanning beam will turn off when it is released. The scanning beam will automatically turn off when a barcode is successfully read. After pressing scan, the scanner beam will be emitted continuously, flashing on and off, until the scan key is pressed again. Turns off the scanner. The scanning beam will not be emitted after pressing SCAN key

Autorun The Autorun feature is used to automatically run a specific program when powering on the HT580. Below is a list of the five possible options for the autorun configuration, and explanations of what they do.

ITEM

DESCRIPTION

Terminal Mode

Always run terminal mode after powering on the HT580

FormCaching

Always run FormCaching after powering on the HT580.

EasyJob

Always run EasyJob after powering on HT580.

Resume

Load previous program running before powering off.

OFF

Always start at the main menu.

Memory The Memory setting is used to display total memory and free space on the HT580.

Buzzer The Buzzer setting will allow you turn the buzzer on the keys ON/OFF. Press MENU to switch between ON/OFF. Default setting is ON.

18

Page 18

Chapter 2 Using the Hardware

Key The Key setting is used to switch the functionality of the ENTER key, with that of the ESCAPE key. Once this setting is enabled, the ESCAPE key will act as the ENTER key, and the ENTER key will act as the ESCAPE key.

Modem Unitech provides a modem cradle as an accessory for the HT580. With the cradle, a user can transfer data through the phone line. In general, a system administrator needs to setup a host PC to automatically dial out to the modem cradle and issue the command for either data communication or remote control. For such configuration, it is necessary to setup the device to automatically pick the phone up when the host calls the modem. This is done with the “AUTO ANSWER” option. The user can also directly call the remote host PC from the modem cradle via the HT580. To do this, it is necessary to set up the remote PC’s phone number in the HT580. Below is a list of the options for modem settings and a description of what they do. ITEM PHONE NUMBER AUTO ANSWER

DIAL OUT HANG UP

DESCRIPTION To set up the remote PC’s phone number Send ATS0=1 [enter] to modem cradle. The modem cradle will automatically pick up the phone after one ring tone. You will get an error message if HT580 is not plugged into the cradle or if the modem cradle is powered off. Dial Out calls the host PC. The PC must wait for a phone call. Hangs up the phone call if the HT580 is connected.

19

Page 19

Chapter 2 Using the Hardware

Supervisor Mode When entering into Supervisor mode, you will be required to input a password. The default password is “580”. From the Supervisor settings menu, you are given the following options: 1. COMM 3.FORM 5.PSWD 7. DIAG

2. TERM 4. PWR 6. BAR 8. SYS

Communication < COMM > This feature is used to set up communication ports, options and protocols. Below are all of the settings and their options. ITEM

OPTIONS

DEFAULT

PORT BAUD RATE

RS232/USB , BLUETOOTH, MODEM 9600bps, 19200bps, 38400bps, 57600 bps

PARITY DATA BITS STOP BITS PROTOCOL ADDRESS

NONE, ODD, EVEN 8, 7 1, 2 MULTI, NONE “A” ~ “Y” or “0” ~ “6”

RS232/USB Default for both RS232 and Bluetooth is 38400bps. NONE 8 1 Multi A

Port The 4 port interfaces are connected to the same serial port on the HT580. If modem or RS232 is selected, any output data from the HT580 will be sent to those ports. (If USB is selected, the HT580 still communicates via serial port emulation.) For Bluetooth, please refer to the section “Communication” for a guide through Bluetooth communication setup. Address It is necessary to set a unique address if the user wants to identify each terminal separately for communication. There are 32 different available addresses, “A” ~ “Y” and “0” ~ “6”. 20

Page 20

Chapter 2 Using the Hardware

Protocol To communicate with Unitech’s PT series devices, the HT580 provides multi-protocol. Please refer to the communication section and multi-protocol for more details. NOTE: HT580’s built-in Bluetooth modem is fixed at 38400bps. If the user changes the port option to Bluetooth, the baud rate will automatically be changed to 38400bps.

Terminal < TERM > The TERM command enables the HT580 to run a built-in Terminal emulator. The HT580 will operate as a dumb ASCII terminal when the user select this feature and disable the Formcaching menu. To change the communication settings of Terminal Mode, proceed to the Supervisor Mode and enter Term Setup. When finished, go to the Ready Mode menu and press 2. Terminal ID Each HT580 “Terminal” can be identified by an 8-character string Terminal ID assigned by the user. Initially, the default ID is “HT580”. Valid characters for assigning Terminal ID are alphanumeric characters (‘A’-’Z’, ‘0’-’9’). Hit ENTER to make the selection. Online Use the [ ] key to toggle between below 3 modes, then hit ENTER to make the selection. ITEM LOCAL

DESCRIPTION The HT580 does not transmit gathered data to RS232/USB/Bluetooth. REMOTE NONE The HT580 will output data gathered from the bar code port or keypad to its RS- RS232/USB/Bluetooth with None protocol. REMOTE MULTI The HT580 will output data gathered from the bar code port or keypad to its RS- RS232/USB/Bluetooth with Multi-Protocol. Echo Use the [ ] key to toggle between ON and OFF, then hit ENTER to make the selection. The collected data will be displayed on the HT580 LCD when Echo is set to ON, otherwise data will not be displayed when it is set to OFF.