Inter-character delay
Inter-character delay The maximum rate at which data can be transmitted by the MicroBar NX is affected by the response of the system. By the insertion of an inter-character delay, the MicroBar NX can avoid dropping characters if it is transmitting decoded data too rapidly. This feature can only be used with keyboard wedge and RS-232 interfaces.
Predefined delay values No Delay (*)
10 ms
20 ms
30 ms
40 ms
50 ms
Compose inter-character delay Example
To make your MicroBar NX insert an 80 ms delay between characters: 1. Scan Compose Inter-Character Delay on the next page. 2. Scan
8 then
0.
3. Scan End Selection.
MB/NX/RM/00/E/970131
51
Page 62
Inter-character delay 1
2
3
4
5
6
7
8
9
0
Compose Inter-Character Delay (max 999 ms)
52
End Selection
MB/NX/RM/00/E/970131
Page 63
Inter-message delay
Inter-message delay The maximum rate at which data can be transmitted by the MicroBar NX is affected by the response of the system. An inter-message delay gives the host system time to process each successive message it receives - useful for example when a control code (such as Enter) requiring a response from the host is sent after each record. Each time the MicroBar NX receives a message, an inter-message delay cycle is activated. If the MicroBar NX receives a new message before the end of the inter-message delay, it stores the previous message in a "rolling buffer" memory and the cycle starts again. When no more messages are received before the end of an inter-message delay cycle, all the messages stored in the buffer are transmitted to the host system. The messages are transmitted First-In-First-Out and each message is separated by the inter-message delay. This feature can be used with all host interfaces.
Predefined delay values No Delay (*)
100 ms
500 ms
1000 ms (1 sec)
2000 ms (2 sec)
5000 ms (5 sec)
MB/NX/RM/00/E/970131
53
Page 64
Inter-message delay Compose inter-message delay Example
To make your MicroBar NX insert a 200 ms delay between messages: 1. Scan Compose Inter-Message Delay on the next page. 2. Scan 2
0 then
0.
3. Scan End Selection.
54
MB/NX/RM/00/E/970131
Page 65
Inter-message delay 1
2
3
4
5
6
7
8
9
0
Compose Inter-Message Delay (max 6000 ms)
MB/NX/RM/00/E/970131
End Selection
55
Page 66
Interfaces
Interfaces Interface types If you reset your MicroBar NX to its factory default settings (Ð Reset all configuration parameters), no interface type is selected (null interface). In this case, you will have to reenter the appropriate interface number for your system ( Ð Compose interface number ). Ð Keyboard wedge Ð RS-232
Identifying the interface If the MicroBar NX has already been programmed with an interface number, the green indicator LED of the MicroBar NX will flash a number of times to indicate the host system configuration. If no interface number has been programmed - which may be the case when you set up for the first time - the indicator LED will stay green.
green LED flashes 2 flashes host system configuration • RS-232 C / TTL • dual RS-232 C
7 flashes
56 keyboard wedge
MB/NX/RM/00/E/970131
Page 67
Keyboard wedge
Keyboard wedge Connection - All except Wyse, DEC 220 / 320 / 420 keyboard input connector
Ø
• undecoded pen host computer
• wand emulation device • 5V power supply (if required)
2
5V power supply (if required)
3
1
4 input device
1. Switch off the host system. 2. Disconnect the keyboard from the host computer. 3. Use the appropriate keyboard wedge cables to connect the MicroBar NX between the keyboard and the host computer. 4. Connect your data input devices to the MicroBar NX. 5. If your host system requires an external power supply: •
Connect the power supply (jack or modular plug) to the MicroBar NX.
•
Plug the power supply into the mains socket.
6. Switch on the host system.
M Do not switch on the host system until you have connected up and plugged in the external power supply. MB/NX/RM/00/E/970131
57
Page 68
Keyboard wedge Connection - Wyse, DEC 220 / 320 / 420 keyboard input connector
Ø host computer
• undecoded pen • low-power wand emulation device (< 50 mA) 5V power supply (modular plug)
2
5V power supply (jack)
3
1
4 input device
1. Switch off the host system. 2. Disconnect the keyboard from the host computer. 3. Use the appropriate keyboard wedge cable to connect the MicroBar NX between the keyboard and the host computer. 4. Connect your data input devices to the MicroBar NX. 5. Connect the external power supply (jack or modular plug) to the MicroBar NX. 6. Plug the power supply into the mains socket. 7. Switch on the host system.
M Do not switch on the host system until you have connected up and plugged in the external power supply. 58
MB/NX/RM/00/E/970131
Page 69
Keyboard wedge Predefined interface numbers If your interface number is not among the predefined interface numbers, you must compose the number yourself (Ð Compose interface number ).
IBM PC AT and compatibles N° 200 - QWERTY - English
N° 201 - AZERTY - French
N° 204 - QWERTZ - German
N° 205 - QWERTY - Swedish / Finnish
N° 207 - QWERTY - Norwegian
N° 208 - QWERTY - Danish
N° 2020 - QWERTZ - Swiss / French
MB/NX/RM/00/E/970131
59
Page 70
Keyboard wedge IBM 31xx, 32xx, 34xx N° 230 - QWERTY - English
N° 231 - AZERTY - French
N° 232 - AZERTY - international
N° 234 - QWERTZ - German
N° 2310 - QWERTY - data entry
N° 2313 - AZERTY - data entry
N° 2314 - QWERTZ - numeric keypad
60