Page 51

Data reformatting 2.b.1. Define the reformatting sequence Use the decimal values of the ASCII character codes to indicate the reformatted transmission sequence for the barcode data characters you read and scan End Selection to finish (ÐASCII character codes ). ASCII character SOH (01h) corresponds to the first decoded data character, ASCII character STX (02h) corresponds to the second decoded data character, etc. You can enter the same ASCII character more than once if you want to repeat an input character a number of times. If you do not enter the ASCII position codes for one or more of the characters received, these characters will be removed from the transmission sequence. Example •

“<SOH> <STX> <ETX> “ indicates that you want to transmit the first three characters in the same order that you receive them.

•

For the same input string, “<STX > <SOH>“ indicates that you want to transmit the second character received before the first character and you do not want to transmit the third character.

Define Reformatting Sequence - SOH (01h) to DEL (7Fh)

MB/NX/RM/00/E/970131

41

Page 52

Data reformatting 2.b.2. Define additional characters You may need to insert additional characters - special control characters required by your host system or application for example - in the reformatted transmission sequence. Procedure 1. Scan Define Character 1, 2, 3, 4 or 5. 2. Scan the ASCII code of the additional character you want to define. (Ð ASCII character codes for RS-232 host systems) (Ð ASCII character codes and Keyboard wedge - Additional control characters for keyboard wedge host systems) 3. Insert the characters “y” (79h), “z” (7Ah), “{“ (7Bh), “|” (7Ch), or “}” (7Dh ) for Characters 1, 2, 3, 4, or 5 when you define the reformatted transmission sequence (Ð 2.b.1. Define the reformatting sequence above).

Define Character 1 For “y” (79h)

Define Character 2 For “z” (7Ah)

Define Character 3 For “{“ (7Bh)

Define Character 4 For “|” (7Ch)

Define Character 5 For “}” (7Dh )

42

MB/NX/RM/00/E/970131

Page 53

Data reformatting 2.b.3. Define 1 or 2 delays You may need to insert 1 or 2 delay characters in the reformatted transmission sequence - for example to give the host system enough time to process a page jump character before the MicroBar NX transmits the next character. Delays can also be used in conjunction with additional control characters to split a single code into two fields. Delay values are defined in increments of 50 ms using the Number codes provided at the end of this manual - if you enter “1”, the delay will be 50 ms, if you enter “2”, the delay will be 100 ms, to define a delay of 1 second (1000 ms = 50 ms x 20), you must enter the numbers “2” and “0”. The maximum delay is 78 x 50 ms = 3.9 seconds. Procedure 1. Scan a Define Delay code. 2. Scan a number corresponding to the desired 50 ms increment (Ð Number codes or inside back cover of this manual). 3. Scan End Selection. 4. Insert the characters “~” (7Eh) and/or DEL (7Fh) for Delays 1 and 2 when you define the reformatted transmission sequence ( Ð 2.b.1. Define the reformatting sequence above). Define Delay 1 For “~” (7Eh)

Define Delay 2 For DEL (7Fh)

MB/NX/RM/00/E/970131

43

Page 54

Data reformatting 2.b.4. Substitute/delete characters before transmission You can configure the MicroBar NX to systematically redefine or delete specific characters received in the input data - for example, you may want to transmit the number “1” every time you read the letter “A” in the input data, or you may want to systematically remove all zeros, spaces or hyphens from the input data. 1. Scan Define Substitution Characters. 2. Scan the ASCII code of the character you want to redefine (or delete!). (RS-232 host systems Ð ASCII character codes ) (keyboard wedge host systems Ð ASCII character codes and Keyboard wedge - Additional control characters ) 3. Scan the ASCII code of the substitution character you want to define - if the substitution character is ASCII character DEL (7Fh), the input character will be systematically deleted each time it is encountered. 4. Repeat steps 2 and 3 to define other substitution pairs if required. 5. Scan End Selection to finish. You can define a maximum of 80 substitution pairs. Reset All Substitution Definitions removes all the current substitution definitions–no input characters are redefined before transmission. Cancel Current Definition In Progress allows you to abort a definition in progress without scanning End Selection - the values entered are not taken into account.

Define Substitution Characters

Reset All Substitution Definitions

Cancel Current Definition In Progress

44

MB/NX/RM/00/E/970131

Page 55

Default parameter settings

Default parameter settings Factory default settings for the MaxiScan 2200 configuration parameters are indicated by “*” in this manual. Use the Reset Factory Defaults code to reset all the MicroBar NX parameters to their factory default settings (Ð Reset all configuration parameters ). Ð Parameter list / data strings provides the full list of parameters including default settings. Keep a list of your custom settings - this will be useful if you have to perform a reset.

MB/NX/RM/00/E/970131

45

Page 56

Glossary

Glossary data input devices devices used to enter data through the MicroBar NX to the host system: • pen barcode readers

• laser/CCD barcode readers in wand/laser emulation

• undecoded magstripe readers

•

RS-232 input devices - electronic scales, barcode readers, magstripe readers, . . .

dual RS-232 C

MicroBar NX connected between two systems communicating through an RS-232 link (external power supply usually required)

external power supply

5V mains power supply adapter - necessary if the host system does not provide enough electrical power to drive the MicroBar NX interface number automatically configures the output data transmission parameters for the host system your MicroBar NX is connected to keyboard wedge

MicroBar NX connected between a keyboard and the host system - data from the MicroBar NX is transmitted in keyboard emulation mode to provide instant software compatibility (external power supply usually required)

MicroBar NX decoder and interface unit used to connect one or more data input devices to a data processing host system - keyboard emulation for PCs and terminals, RS-232 communication, . . .

operating parameters parameters that affect the way the MicroBar NX operates - general operating parameters include beep/LED settings, operating mode settings, etc.

output transmission parameters host-system interface-specific communication parameters - in certain cases they need to be modified to optimize the performance of the MicroBar NX symbology barcode type or "family" - Code 39, UPC and EAN are examples of common symbologies

46

MB/NX/RM/00/E/970131

Page 57

Input devices

Input devices

• undecoded pen • wand emulation device • 5V power supply 5V power supply

• undecoded pen • low-power wand emulation device (< 50 mA) modular plugs 2

3

1 jack

5V power supply 4 DB 9-pin connector

5")

undecoded magstripe reader decoded / undecoded laser / CCD scanner (wand / laser emulation) RS-232 TTL input device (electronic scales, barcode reader, magstripe reader)

1 pen - DB 9-pin connector

2 pens - modular plug connectors with dual pen adaptor

MB/NX/RM/00/E/970131

47

Page 58

Input identification

Input identification Input identifier position The MicroBar NX can send an input identification string before or after the barcode data to identify the input device and input port used. If there is a preamble or postamble, the input identification string is inserted between the preamble/postamble and the barcode data:

<preamble>

<Input_id>

<barcode data>

<preamble>

<barcode data>

<postamble> or

< Input_id >

<postamble>

The input identification string can contain a maximum of 15 characters.

Before Barcode Data (*)

After Barcode Data kbd wedge RS-232

Port 1 (RS-232) / Port 3 (Keyboard Wedge)

2

3

1

4

Compose Input Identifier - Port 1 / Port 3

No Input Identifier - Port 1 / Port 3

48

MB/NX/RM/00/E/970131

Page 59

Input identification 2

3

1

Port 4 4

Compose Input Identifier - Port 4

No Input Identifier - Port 4

2

3

1

Port 5 4 5

Compose Input Identifier - Port 5

No Input Identifier - Port 5

MB/NX/RM/00/E/970131

49

Page 60

Installation procedure

Installation procedure The MicroBar NX Installation Guide tells you step by step how to install and set up your MicroBar NX to operate successfully in most working situations.

General installation / configuration procedure 1. Check you have everything you need (Ð Product checklist). 2. Switch off the host system and connect up your MicroBar NX (Ð Connection for your interface). 3. Switch on the host system. 4. Scan the interface number for your host system (Ð Predefined interface numbers for your interface or Compose interface number). 5. Customize the data transmission settings for your interface if required. 6. Customize the settings for output transmission to your host system if required (Ð Data transmission parameters for your interface). 7. Customize the data input parameter settings if required (Ð Symbologies, Laser scanner input devices, Magstripe input devices, RS-232 input devices). 8. Customize the MicroBar NX operating settings if required (Ð Parameter list / data strings and individual operating parameter entries).

50

MB/NX/RM/00/E/970131