Page 161
Symbologies - Codabar
Symbologies - Codabar Activation Not Active (*)
Active
Default values Start/stop bars
-
Not Transmitted
CLSI library system
-
Not Active
Check digit (AIM recommendation)
-
Not Used
Concatenation
-
Read Adjacent Codes As Single Code
-
Transmit Single Codes And Concatenated Codes
MB/NX/RM/00/E/970131
151
Page 162
Symbologies - Codabar Start/stop Not Transmitted (*)
a, b, c, d
A, B, C, D a, b, c, d
/ t, n, *, e
DC1, DC2, DC3, DC4
CLSI library system Libraries in the CLSI system used in the United States require the insertion of spaces within the 14-character label - for example, the label 39990000192148 is transmitted as 3 9990 00019 2148. The start/stop code can be transmitted or not transmitted as required. Not Active (*)
Active
152
MB/NX/RM/00/E/970131
Page 163
Symbologies - Codabar Check digit (AIM recommendation) While Codabar has no check character, AIM has a recommended character. Each Codabar data character has a value assigned to it. Not Used (*)
Checked And Transmitted
Checked But Not Transmitted
AIM data character values
MB/NX/RM/00/E/970131 data character value data character value
0 1 2 3 4 5 6 7 8 9
0 1 2 3 4 5 6 7 8 9
$ : / , + A B C D
10 11 12 13 14 15 16 17 18 19
153
Page 164
Symbologies - Codabar Calculation of the check digit
1. The values corresponding to all the Codabar data characters in the message (including Start/Stop characters) are added together to make a total. 2. The data character which must be added to this total to make a multiple of 16 is the check character.
Example
154 message:
A01234B characters:
A 0 1 2 3 4 B values:
16 0 1 2 3 4 17 sum of character values:
43 next multiple of 16:
48
48 - 43 =
5 (the check character)
final message:
A012345B
MB/NX/RM/00/E/970131
Page 165
Symbologies - Codabar Concatenation If you scan two or more Codabar bar codes placed side by side in a single sweep, the MicroBar NX can transmit the data as a single message. If the scanner is configured to transmit start/stop characters, the MicroBar NX will transmit the first start and last stop characters only - intermediate start/stop characters are not transmitted. These concatenation functions are also available for the ABC format used by the American Blood Commission, which has the following restrictions for start/stop characters:
bar_code_1 (left) Start = A, B, C, or D - - Stop = D
...
bar_code_n (right) Start = D - - Stop = A, B, C or D
Read Adjacent Codes As Single Code (*)
Deactivate - Read Single Codes Only
Read Adjacent Codes If Stop 1 = Start 2
ABC (American Blood Commission)
Transmit Single Codes And Concatenated Codes (*)
Transmit Concatenated Codes Only
MB/NX/RM/00/E/970131
155
Page 166
Symbologies - Code 11
Symbologies - Code 11 Activation Not Active (*)
Active
Default values Check digits
-
1 Check Digit
-
Checked And Transmitted
Check digits 1 Check Digit (*)
2 Check Digits
Checked And Transmitted (*)
Checked But Not Transmitted
156
MB/NX/RM/00/E/970131
Page 167
Symbologies - Code 39 (*)
Symbologies - Code 39 (*) Activation Select the desired Code 39 format and scan Active to enable. Full ASCII characters are encoded using one of the four control characters ($, %, /, +) in combination with a letter (Ð Full ASCII conversion chart - Code 39 on the next page). Active (*)
Not Active
Standard 43 Characters (*)
Full ASCII
Default values Code 39 format
-
Standard 43 Characters
Start/stop
-
Not Transmitted
-
Active "*" Only
Check digit
-
Not Used
Multiread
-
Not Active
MB/NX/RM/00/E/970131
157
Page 168
Symbologies - Code 39 (*) Full ASCII conversion chart - Code 39 Code 39 ASCII
Hex Code 39 ASCII
Hex Code 39 ASCII
Hex Code 39 ASCII
Hex
20
40
60
%U
NUL
00
Space
SP
%V
@
%W
‘
$A
SOH
01
/A
!
21
A
A
41
+A a
61
$B
STX
02
/B
"
22
B
B
42
+B b
62
$C
ETX
03
/C
#
23
C
C
43
+C c
63
$D
EOT
04
$
$
24
D
D
44
+D d
64
$E
ENQ
05
%
%
25
E
E
45
+E e
65
$F
ACK
06
/F
&
26
F
F
46
+F f
66
$G
BEL
07
/G
’
27
G
G
47
+G g
67
$H
BS
08
/H
(
28
H
H
48
+H h
68
$I
HT
09
/I
)
29
I
I
49
+I i
69
$J
LF
0A
/J
*
2A
J
J
4A
+J j
6A
$K
VT
0B
+
+
2B
K
K
4B
+K k
6B
$L
FF
0C
/L
,
2C
L
L
4C
+L l
6C
$M
CR
0D
/M
-
2D
M
M
4D
+M m
6D
$N
SO
0E
/N
.
2E
N
N
4E
+N n
6E
$O
SI
0F
/
/
2F
O
O
4F
+O o
6F
$P
DLE
10
0
0
30
P
P
50
+P p
70
$Q
DC1
11
1
1
31
Q
Q
51
+Q q
71
$R
DC2
12
2
2
32
R
R
52
+R r
72
$S
DC3
13
3
3
33
S
S
45
+S s
73
$T
DC4
14
4
4
34
T
T
54
+T t
74
$U
NAK
15
5
5
35
U
U
55
+U u
75
$V
SYN
16
6
6
36
V
V
56
+V v
76
$W
ETB
17
7
7
37
W
W
57
+W w
77
$X
CAN
18
8
8
38
X
X
58
+X x
78
$Y
EM
19
9
9
39
Y
Y
59
+Y y
79
$Z
SUB
1A
/Z
:
3A
Z
Z
5A
+Z z
7A
%A
ESC
1B
%F
;
3B
%K
[
5B
%P
{
7B
%B
FS
1C
%G
<
3C
%L
\
5C
%Q
|
7C
%C
GS
1D
%H
=
3D
%M
]
5D
%R
}
7D
%D
RS
1E
%I
>
3E
%N
^
5E
%S
~
7E
%E
US
1F
%J
?
3F
%O
_
5F
%T
DEL
7F
158
MB/NX/RM/00/E/970131
Page 169
Symbologies - Code 39 (*) Start/stop Transmission Not Transmitted (*)
Transmitted
Accepted characters " * " Only (*)
" $ " Only
" $ " And " * " Accepted
MB/NX/RM/00/E/970131
159
Page 170
Symbologies - Code 39 (*) Check digit Check Digit Not Used (*)
Modulo 43 check digit The modulo 43 check digit is a character added to the end of the Code 39 bar code label for extra validation of the data. Checked And Transmitted
Checked But Not Transmitted
French CIP check digit The CIP check digit is used in the French pharmaceutical industry. It is only used for codes with seven characters. Checked And Transmitted
Checked But Not Transmitted
Italian CPI check digit The Italian CPI check digit is used in the Italian pharmaceutical industry. If the bar code 39 read does not match an Italian checksum, it is transmitted as a standard Code 39. Checked And Transmitted
Checked But Not Transmitted
160
MB/NX/RM/00/E/970131