Page 151
RS-232 - Slave mode 3. Adapt the strings to slave mode format
Remove the backslash separator characters from the data strings obtained in Display Data String Mode and adapt each string to slave mode format: <startB> (<68>)
Example
<command>
<checksum >
<stop> (<6A>)
To activate Code 39 from the host terminal in slave mode, you must send the following string from the host terminal: 68414C605E6A
4. Send the commands from the host terminal to the MicroBar NX
Transmit the commands from the host to the MicroBar NX. You can send slave mode commands individually or make a list in a command file. The values displayed in Display Data String Mode are hexadecimal values. Make sure that the values you send from the host system correspond to these values. In our example, the MicroBar NX must receive the hexadecimal value 41 or its equivalent (ASCII character "A", for example), not the decimal value 41.
5. Save the configuration and quit slave mode
Commands sent in slave mode are not saved automatically in the MicroBar NX memory. If you wish to save the new configuration, enter the Update Current Configuration command (Ð Configuration modes - Temporary configuration mode) - manually or using slave mode. To quit slave mode, rescan your normal interface number (Ð RS-232 - Predefined interface numbers) and reconfigure the RS-232 output parameters to suit your system if required.
MB/NX/RM/00/E/970131
141
Page 152
Software version identification
Software version identification Software version information is useful if you have a problem and need to contact your UBI representative (Ð Troubleshooting ).
Version indications Textual display on the host terminal screen
If the MicroBar NX is connected to a host terminal with a display monitor, the software version is displayed on the screen: * MicroBar NX * V1.4_ * Copyright UBI STC * JAN. 17 1997 *
Software version beeps / green indicator LED flashes
Each digit of the software version number (N.N) is indicated by a number of long beeps and green indicator LED flashes corresponding to (version_number + 1). The specific software version letter if applicable (n.nL) is represented by a number of short beeps corresponding to the equivalent alphabetical position of the letter. Example
Specific software version 1.4A is indicated by: 2 long beeps a pause
5 long beeps a pause
1 short beep
Software Version
142
MB/NX/RM/00/E/970131
Page 153
Symbologies
Symbologies If your application uses a ScanPlus as an input device (wand or laser emulation), the same symbologies (and code lengths if applicable) must be activated for the ScanPlus and the MicroBar NX. Disconnect the ScanPlus to make sure that ScanPlus Transparent Configuration Mode is disabled before you configure the ScanPlus.
Available symbologies To optimize the performance of your MicroBar NX and to ensure trouble-free scanning, do not select symbologies that you do not need (Ð Symbologies - Activation).
Ð Symbologies - Ames Code Ð Symbologies - Codabar Ð Symbologies - Code 11 Ð Symbologies - Code 39 (*) Ð Symbologies - Code 93 Ð Symbologies - Code 128 / EAN 128 Ð Symbologies - Interleaved 2 of 5 Ð Symbologies - Matrix 2 of 5 Ð Symbologies - MSI Code Ð Symbologies - Plessey Code Ð Symbologies - Standard 2 of 5 Ð Symbologies - Telepen Ð Symbologies - UPC/EAN code families (*) (UPC-A, UPC-E, EAN-8, EAN-13)
MB/NX/RM/00/E/970131
143
Page 154
Symbologies Default symbologies Code 39 and the UPC/EAN code families are preselected by default. When you install and set up your MicroBar NX for the first time, all the symbology parameters are set to their factory default settings - indicated by an asterisk (*) in this manual. The symbology default settings are global factory defaults - they are independent of the different symbology activation codes. If you want to reset all the default symbology settings, you can scan the Reset Factory Defaults bar code (Ð Reset all configuration parameters), but you will then have to completely reconfigure your MaxiScan 2200. It is often easier to scan Disable All Symbologies and reactivate individual symbologies ( Ð Symbologies - Activation ). Keep a list of your custom settings - this will be useful if you have to perform a reset.
Character formats and MicroBar NX transmission format symbology
144 character format supported
MicroBar NX transmission format
•
Code 39 alphanumeric - letter case not defined upper case
• • •
Code 93 Code 128 Telepen alphanumeric full ASCII - letter case defined full ASCII - lower case/upper case as defined
• • • • • • •
Ames Code Codabar Code 11 Interleaved 2 of 5 Matrix 2 of 5 Standard 2 of 5 UPC/EAN code set numerical numerical
MB/NX/RM/00/E/970131
Page 155
Symbologies Barcode length and data security The reliability of the barcode data transmitted can depend on the symbologies used - some symbologies are more "fragile" than others and errors may occur due to incorrect interpretation of code lengths. For the Interleaved 2 of 5 and Standard 2 of 5 symbologies, the Define 1 Or 2 Or 3 Fixed Lengths parameters allow you to configure the MicroBar NX to only accept codes which meet certain length requirements - the safest option if you know that all the codes in your application have fixed lengths. As well as barcode length parameters, other configuration parameters are available for laser scanners to help to increase the security of the data transmitted (Ð Laser scanner input devices - Consecutive same read data validation ).
M Each symbology (Interleaved 2 of 5 and Standard 2 of 5) has a different set of configuration codes for barcode length parameters - you must only use the codes for your symbology.
MB/NX/RM/00/E/970131
145
Page 156
Symbologies - Activation
Symbologies - Activation To optimize the performance of your MicroBar NX and to ensure trouble-free scanning, do not select symbologies that you do not need. The symbology activation codes are also provided with the parameters for each symbology (Ð appropriate Symbologies section for your symbology).
Disable All Symbologies Disable All Symbologies deactivates all the symbologies activated. If you want to deactivate individual symbologies, use the Not Active codes for each symbology. Disable All Symbologies does not reset the individual parameter settings for each symbology. When you reactivate a symbology, you recover the parameter settings stored in memory for that symbology when it was disabled. If you want to reset all the individual symbology parameters to their factory default values, you must scan the Reset Factory Defaults bar code ( Ð Reset all configuration parameters ). Disable All Symbologies
146
MB/NX/RM/00/E/970131
Page 157
Symbologies - Activation Symbology activation codes Ames Code - Not Active (*)
Ames Code - Active
Codabar - Not Active (*)
Codabar - Active
Code 11 - Not Active (*)
Code 11 - Active
Code 39 - Not Active
Code 39 - Active (*) The default format for Code 39 is Standard 43 Characters. Code 93 - Not Active (*)
Code 93 - Active
MB/NX/RM/00/E/970131
147
Page 158
Symbologies - Activation Code 128 / EAN 128 - Not Active (*)
Code 128 / EAN 128 - Active
Interleaved 2 of 5 - Not Active (*)
Interleaved 2 of 5 - Active
Matrix 2 of 5 - Not Active (*)
Matrix 2 of 5 - Active
MSI Code - Not Active (*)
MSI Code - Active
Plessey Code - Not Active (*)
Plessey Code - Active
Standard 2 of 5 - Not Active (*)
Standard 2 of 5 - Active The default format for Standard 2 of 5 is Identicon (6 Bars).
148
MB/NX/RM/00/E/970131
Page 159
Symbologies - Activation Telepen - Not Active (*)
Telepen - Active
UPC/EAN code families Select the desired UPC/EAN format configuration and scan UPC/EAN - Active to enable.
UPC/EAN - Not Active
UPC/EAN - Active (*)
UPC-A Deactivated
UPC-E Deactivated
EAN-8 Deactivated
EAN-13 Deactivated
MB/NX/RM/00/E/970131
149
Page 160
Symbologies - Ames Code
Symbologies - Ames Code Activation Not Active (*)
Active
150
MB/NX/RM/00/E/970131