What is in it
Intermec's installation guide for the MaxiScan 3100, a range of compact fixed bar code scanners offered with CCD (3100 SR) or laser (3100 ST and ML) scanning. It covers integration and reading position, reading moving bar codes, mounting and dimensions, RS-232 C, RS-422/485 and current loop connections, input/output synchronization, setup with EasySet, slave mode, the optional MaxiScan Connexion System box, the RS-232 to RS-422/485 conversion cable, and technical characteristics with reading distances.
Its parts
- Before you start
- Installation
- Connections
- Input / output synchronization
- Setup
- Slave mode
- MaxiScan Connexion System (option)
- Conversion cable (RS-232 C to RS-422 / 485)
- Technical characteristics
From the manual · read page by page
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Installation guide for the Intermec MaxiScan 3100 fixed station bar code scanners, covering the models printed as MaxiScan 3100 SR (CCD), ST and ML (laser). It explains mounting and reading position, wiring and host connections, trigger input and output, setup with EasySet or bar codes, and slave mode commands.
- What it is
- Compact fixed bar code scanner; SR uses a CCD imager, ST and ML use a laser p. 3, 7
- Host interfaces
- 15-pin subD female connector; RS-232 C standard; RS-422 or RS-485 with a conversion cable; passive current loop with MCS connection box P/N 0-531029-06 p. 43
- Power
- 7 to 25 VDC full-wave rectified unregulated, 2.5 Watt p. 43
- Scan rate
- SR: 100 to 800 scans/second; ST / ML: 200 scans/second p. 43, 45
- Light source
- SR: 4 LEDs at 640 nm with high resolution CCD; ST / ML: laser diode at 660 nm p. 43, 45
- ML scan lines
- ML: 10 scan lines through an angle of 10° p. 9
- Symbologies
- Codabar, Code 39, Code 93, Code 128, MSI, Plessey, EAN/UPC with 2-5 add-on, Interleaved 2 of 5, Matrix 2 of 5, Standard / Industrial 2 of 5, PDF 417 p. 43
- Trigger input and output
- Hardware trigger input on pins 5 and 6, output on pins 7 and 8; current limited to 20 mA p. 21, 22, 23
- Setup
- EasySet configuration software, configuration bar codes, or slave mode commands p. 25
- Default serial settings
- 9600 baud, 7 data bits, even parity, 2 stop bits, CR + LF postamble p. 28
- Temperature
- Operating 0°C to 40°C (32°F to 104°F); storage -25°C to 60°C (-13°F to 140°F) p. 44
- Sealing
- The manual states IP65 / Nema 12 sealing against dust p. 44
- Cables
- RS-232 C Y cable with power input 0-530062-02; RS-232 cable from MCS box to host 0-530062-01 p. 49
- Power supplies
- US 3-531029-08; Europe (except UK) 0-531029-02; UK 0-531029-04 p. 49
What this manual walks you through
- Choosing the location and reading angles p. 8, 9
- Reading moving bar codes and pass-through speed p. 10, 11
- Wiring the 15-pin scanner connector p. 17
- RS-232 C, RS-422 / RS-485 and current loop connections p. 18, 19
- Setting up trigger input and output p. 21, 22, 23
- Setting up the scanner with EasySet p. 25, 26
- Basic setup by scanning configuration bar codes p. 27, 28, 29
- Sending setup commands in slave mode p. 31, 32, 33
- MCS connection box port pinouts p. 35, 36, 37, 38, 39, 40
- Wiring the RS-422 / RS-485 conversion cable p. 41, 42
Good to know
- The SR model is not usually suitable for moving bar codes. p. 10
- A small skew angle of at least 2 to 3 degrees prevents specular reflection. p. 9
- Synchronization current from external devices must be limited to 20 mA. p. 40
- On a long RS-422 or RS-485 cable, fit a resistor matching the cable impedance between pins 1 and 3. p. 42
- ST / ML: using controls or procedures other than those specified can result in hazardous laser light. p. 3
Questions this manual answers
What power does the MaxiScan 3100 need?
7 to 25 VDC, full-wave rectified unregulated, 2.5 Watt, on pin 10 of its 15-pin connector. p. 17, 43
What do the MaxiScan 3100 beeps mean?
Red LED and 2 beeps at power on, 1 beep on a good read, 6 beeps for a configuration error, 3 long beeps for an EEPROM error. p. 44
What are the MaxiScan 3100 default serial settings?
9600 baud, 7 data bits, even parity, 2 stop bits, with a carriage return and line feed after the data. p. 28
How do I connect the MaxiScan 3100 to EasySet?
Connect it with the RS-232 C cable P/N 0-530062-02, power on, scan the EasySet setup code, and set the COM port to 19200 baud, 8 data bits, no parity. p. 26
Contents
Chapters and sections
Each line opens the PDF at its page.
- 1 Before you start7
- 2 Installation13
- 3 Connections17
- 4 Input / output synchronization21
- 5 Setup25
- 6 Slave mode31
- 7 MaxiScan Connexion System (option)35
- 8 Conversion cable (RS-232 C to RS-422 / 485)41
- 9 Technical characteristics43