Page 1 of MaxiScan 3100 Fixed Station Scanner Installation Guide

Manual · UBI

MaxiScan 3100 Fixed Station Scanner Installation Guide

Manual50 pagesPDF 1.3 MB

Installation guide for the Intermec MaxiScan 3100 fixed station bar code scanner (SR, ST and ML models).

What this file really is

The old site listed this file as a manual for the UBI M3300. The file is named as a UBI M3300 manual, but it is Intermec's installation guide for the MaxiScan 3100 fixed station scanner and never mentions the M3300.

Download the PDF1.3 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Intermec's installation guide for the MaxiScan 3100, a range of compact fixed bar code scanners offered with CCD (3100 SR) or laser (3100 ST and ML) scanning. It covers integration and reading position, reading moving bar codes, mounting and dimensions, RS-232 C, RS-422/485 and current loop connections, input/output synchronization, setup with EasySet, slave mode, the optional MaxiScan Connexion System box, the RS-232 to RS-422/485 conversion cable, and technical characteristics with reading distances.

Its parts

  1. Before you start
  2. Installation
  3. Connections
  4. Input / output synchronization
  5. Setup
  6. Slave mode
  7. MaxiScan Connexion System (option)
  8. Conversion cable (RS-232 C to RS-422 / 485)
  9. Technical characteristics

From the manual · read page by page

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Installation guide for the Intermec MaxiScan 3100 fixed station bar code scanners, covering the models printed as MaxiScan 3100 SR (CCD), ST and ML (laser). It explains mounting and reading position, wiring and host connections, trigger input and output, setup with EasySet or bar codes, and slave mode commands.

What it is
Compact fixed bar code scanner; SR uses a CCD imager, ST and ML use a laser p. 3, 7
Host interfaces
15-pin subD female connector; RS-232 C standard; RS-422 or RS-485 with a conversion cable; passive current loop with MCS connection box P/N 0-531029-06 p. 43
Power
7 to 25 VDC full-wave rectified unregulated, 2.5 Watt p. 43
Scan rate
SR: 100 to 800 scans/second; ST / ML: 200 scans/second p. 43, 45
Light source
SR: 4 LEDs at 640 nm with high resolution CCD; ST / ML: laser diode at 660 nm p. 43, 45
ML scan lines
ML: 10 scan lines through an angle of 10° p. 9
Symbologies
Codabar, Code 39, Code 93, Code 128, MSI, Plessey, EAN/UPC with 2-5 add-on, Interleaved 2 of 5, Matrix 2 of 5, Standard / Industrial 2 of 5, PDF 417 p. 43
Trigger input and output
Hardware trigger input on pins 5 and 6, output on pins 7 and 8; current limited to 20 mA p. 21, 22, 23
Setup
EasySet configuration software, configuration bar codes, or slave mode commands p. 25
Default serial settings
9600 baud, 7 data bits, even parity, 2 stop bits, CR + LF postamble p. 28
Temperature
Operating 0°C to 40°C (32°F to 104°F); storage -25°C to 60°C (-13°F to 140°F) p. 44
Sealing
The manual states IP65 / Nema 12 sealing against dust p. 44
Cables
RS-232 C Y cable with power input 0-530062-02; RS-232 cable from MCS box to host 0-530062-01 p. 49
Power supplies
US 3-531029-08; Europe (except UK) 0-531029-02; UK 0-531029-04 p. 49

What this manual walks you through

  • Choosing the location and reading angles p. 8, 9
  • Reading moving bar codes and pass-through speed p. 10, 11
  • Wiring the 15-pin scanner connector p. 17
  • RS-232 C, RS-422 / RS-485 and current loop connections p. 18, 19
  • Setting up trigger input and output p. 21, 22, 23
  • Setting up the scanner with EasySet p. 25, 26
  • Basic setup by scanning configuration bar codes p. 27, 28, 29
  • Sending setup commands in slave mode p. 31, 32, 33
  • MCS connection box port pinouts p. 35, 36, 37, 38, 39, 40
  • Wiring the RS-422 / RS-485 conversion cable p. 41, 42

Good to know

  • The SR model is not usually suitable for moving bar codes. p. 10
  • A small skew angle of at least 2 to 3 degrees prevents specular reflection. p. 9
  • Synchronization current from external devices must be limited to 20 mA. p. 40
  • On a long RS-422 or RS-485 cable, fit a resistor matching the cable impedance between pins 1 and 3. p. 42
  • ST / ML: using controls or procedures other than those specified can result in hazardous laser light. p. 3

Questions this manual answers

What power does the MaxiScan 3100 need?

7 to 25 VDC, full-wave rectified unregulated, 2.5 Watt, on pin 10 of its 15-pin connector. p. 17, 43

What do the MaxiScan 3100 beeps mean?

Red LED and 2 beeps at power on, 1 beep on a good read, 6 beeps for a configuration error, 3 long beeps for an EEPROM error. p. 44

What are the MaxiScan 3100 default serial settings?

9600 baud, 7 data bits, even parity, 2 stop bits, with a carriage return and line feed after the data. p. 28

How do I connect the MaxiScan 3100 to EasySet?

Connect it with the RS-232 C cable P/N 0-530062-02, power on, scan the EasySet setup code, and set the COM port to 19200 baud, 8 data bits, no parity. p. 26

Can the MaxiScan 3100 be triggered by a photocell?

Yes. An external device such as an opto-coupled cell on pins 5 and 6 can trigger reading, with current limited to 20 mA. p. 21, 22

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 Before you start7
    1. Introduction7
    2. Integration considerations7
    3. Location and reading position8
    4. Reading moving bar codes10
  2. 2 Installation13
    1. Mounting13
    2. Adjustable raised stand (option)14
    3. Dimensions15
  3. 3 Connections17
    1. MaxiScan 3100 connector17
    2. RS-232 C connection18
    3. RS-232 C connection with synchronization18
    4. RS-422 / RS-485 connection19
    5. Current loop connection19
  4. 4 Input / output synchronization21
    1. Input synchronization21
    2. Output synchronization23
  5. 5 Setup25
    1. Online setup with EasySet26
    2. Basic setup27
  6. 6 Slave mode31
    1. Calculating the checksum32
    2. Simplified slave mode32
  7. 7 MaxiScan Connexion System (option)35
    1. MCS connection box35
    2. Scanner port36
    3. Power supply port37
    4. Host port (RS-232 C)38
    5. Host port (current loop)39
    6. Synchros port40
  8. 8 Conversion cable (RS-232 C to RS-422 / 485)41
    1. Host side connector41
    2. RS-422 host cable connector42
    3. RS-485 host cable connector42
  9. 9 Technical characteristics43
    1. Data (MaxiScan 3100 SR)43
    2. Data (MaxiScan 3100 ST / ML)45
    3. Reading distance (MaxiScan 3100 SR)47
    4. Reading distance (MaxiScan 3100 ST / ML)48
1 more line, from page 49 on
  1. Accessories49

From the PDF’s own bookmarks.

The whole text · 9 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. 1 Before you start7-12
  3. 2 Installation13-16
  4. 3 Connections17-20
  5. 4 Input / output synchronization21-24
  6. 5 Setup25-30
  7. 6 Slave mode31-34
  8. 7 MaxiScan Connexion System (option)35-40
  9. Pages 41 to 5041-50

The file

Revision and size

RevisionP/N 3-510049-01, Edition 1.2, 07/99
PublisherIntermec Technologies Corporation
Pages50
PDF1.3 MB
TextText from the PDF itself; pages 47 and 48 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 50

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 50
Page 2
Page 2of 50
Page 3
Page 3of 50