Page 25

5 Setup There are 3 different ways to set up your MaxiScan 3100 : •

Online setup with EasySet

•

Offline setup

•

Online setup with commands

EasySet System configuration software is the easiest way to set up your MaxiScan 3100. You can download your custom settings directly to the MaxiScan 3100 or print out and scan the corresponding configuration bar codes. The Basic setup section of this manual contains the barcodes to set up your MaxiScan 3100 in a basic configuration. If you want to configure your MaxiScan 3100 dynamically, or if your MaxiScan 3100 is not connected to a PC, use the slave mode to send setup commands directly to your MaxiScan 3100 (see the Slave mode section).

MaxiScan 3100 - Installation Guide

25

Page 26

5 Setup

Online setup with EasySet

➊ System power OFF

RS-232 C cable ➋ Connect (P/N : 0-530062-02)

➌ MaxiScan power ON

➍ System power ON

➎ Scan EasySet setup code

➏ Start EasySet

EasySet

➐ Set the COM port parameters to 19200 baud, 8 data bits, no parity Refer to the EasySet online help for a detailed explanation of how to use the EasySet System configuration software. You can also set up your MaxiScan 3100 offline with barcodes printed from EasySet.

26

MaxiScan 3100 - Installation Guide

Page 27

5 Setup

Basic setup You can set up your MaxiScan 3100 in a basic configuration by scanning configuration bar codes. Follow the instructions in this section. Basic setup does not include all the configuration possibilities of the MaxiScan. For a complete setup, use the EasySet System configuration software (see the Online setup with EasySet section).

➊ Connect MaxiScan power supply

➋ Reset factory defaults (optional)

➌ Select interface RS-232 C

MaxiScan 3100 - Installation Guide

27

Page 28

5 Setup

➍ Customize parameters (*) = default value (9600 baud, 7 data bits, even parity, 2 stop bits, postamble = CR + LF) 9600 baud (*)

19200 baud

7 data bits (*)

8 data bits

Odd parity

Even parity (*)

No parity

Postamble = Carriage Return

Postamble = none

Postamble = Carriage Return + Line Feed (*)

28

MaxiScan 3100 - Installation Guide

Page 29

5 Setup

➎ Disable all symbologies ➏ Select symbologies Code 39

UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> EAN-13)

Code 128 / EAN 128

UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> UPC-A)

➐ Test symbologies

MaxiScan 3100 - Installation Guide

29

Page 30

5 Setup

30

MaxiScan 3100 - Installation Guide