Page 41

8 Conversion cable (RS-232 C to RS-422 / 485) Host side connector

Host side - 15-pin subD female connector Pin 1

Receive / transmit data RX- / TX- (RS-485) Receive data RX- (RS-422)

2

Receive / transmit data RX- / TX- (RS-485) Transmit data TX- (RS-422)

3

Receive / transmit data RX+ / TX+ (RS-485) Receive data RX+ (RS-422)

4

Receive / transmit data RX+ / TX+ (RS-485) Transmit data TX+ (RS-422)

5

Positive synchronization input (SI+)

6

Negative synchronization input (SI-)

7

Positive synchronization output (SO+)

8

Negative synchronization output (SO-)

9

Not connected

10

Power in (7 to 25 VDC unregulated)

11

Ground

12

Reserved

13, 14, 15

MaxiScan 3100 - Installation Guide

Function

Not connected

41

Page 42

8 Conversion cable (RS-232 C to RS-422/485)

RS-422 host cable connector The user must provide the connection between the conversion cable and the host system. If this cable is long, install a resistor between pins 1 and 3. The resistor should have the characteristic impedance of the cable.

Host cable connector 15-pin subD male

RS-485 host cable connector The user must provide the connection between the conversion cable and the host system. Connect pins 1 and 2 and connect pins 3 and 4 of this cable. If the cable is long, install a resistor between pins 1 and 3. The resistor should have the characteristic impedance of the cable.

Host cable connector 15-pin subD male

42

MaxiScan 3100 - Installation Guide

Page 43

9 Technical characteristics Data (MaxiScan 3100 SR) Interface

Host system interface

- RS-232 C (standard configuration) - RS-422 (requires cable P/N 3-530062-01) - RS-485 (requires cable P/N 3-530062-01) - Current loop - passive type (requires MCS connection box P/N 0-531029-06)

Input synchronization

One hardware sync from external device One software sync from host system

Output synchronization

One hardware sync to external device One software sync to host system

Decoding

Symbologies

Codabar, Code 39, Code 93, Code 128, MSI Code, Plessey Code, EAN/UPC (including addon 2-5), Interleaved 2 of 5, Matrix 2 of 5, Standard / Industrial 2 of 5, PDF 417

S can performance

Scan rate

100 to 800 scans/second

Depth of field

See the Reading distance section below

Minimum resolution

See the Reading distance section below

Maximum code width

See the Reading distance section below

Scan angle (width)

65° minimum

Pitch

± 70°

S ke w

± 65°

Print contrast ratio

20% minimum

Light source

4 LEDs at 640 nm

Image sensor

High resolution CCD

Electrical characteristics

Power supply voltage

7 to 25 VDCfull-wave rectified unregulated (2.5 Watt)

Physical characteristics

Width x depth x height

5.6 x 7.4 x 3.5 cm (2.2" x 2.92" x 1.37")

Mounting

In any position using 2 x M4 screws

Connector

15-pin subD female

Optical characteristics

MaxiScan 3100 - Installation Guide

43

Page 44

9 Technical characteristics

Environmental specifications

User interface

44

Operating temperature

0°C to 40°C (32°F to 104°F)

Storage temperature

-25°C to 60°C (-13°F to 140°F)

Relative humidity

10% to 90% non-condensing

Maximum ambient lighting

4 000 lux

Electrostatic discharge

± 8000 V (air discharge) ± 4000 V (contact discharge)

Shock resistance

IEC 68-2-27: 30G, 11ms, 3 axis

Vibration resistance

IEC 68-2-6: 1.5mm amplitude, 10Hz to 55Hz, 3 axis

Sealing (dust etc.)

IP65 / Nema 12

MTBF

> 50 000 hours

Power on

Red LED + 2 beeps

Good read

1 green LED flash + 1 beep (default settings)

Good read (configuration co d e s)

2 beeps

Configuration error

6 beeps

EEPROM error

3 long beeps

MaxiScan 3100 - Installation Guide

Page 45

9 Technical characteristics

Data (MaxiScan 3100 ST / ML) Interface

Host system interface

- RS-232 C (standard configuration) - RS-422 (requires cable P/N 3-530062-01) - RS-485 (requires cable P/N 3-530062-01) - Current loop - passive type (requires MCS connection box P/N 0-531029-06)

Input synchronization

One hardware sync from external device One software sync from host system

Output synchronization

One hardware sync to external device One software sync to host system

Decoding

Symbologies

Codabar, Code 39, Code 93, Code 128, MSI Code, Plessey Code, EAN/UPC (including add-on 2-5), Interleaved 2 of 5, Matrix 2 of 5, Standard / Industrial 2 of 5, P D F 417

S can performance

Scan rate

200 scans/second

Depth of field

See the Reading distance section below

Minimum resolution

See the Reading distance section below

Maximum code width

See the Reading distance section below

Scan angle (width)

65° minimum

Pitch

± 70°

S ke w

± 65°

Print contrast ratio

20% minimum

Scan lines

10 (MaxiScan 3100 ML only)

Scan angle (height)

10° (MaxiScan 3100 ML only)

Optical characteristics

Light source laser diode at 660 nm Laser class: IEC Class 2. US CDRH Class II

Electrical characteristics

Power supply voltage

7 to 25 VDC full-wave rectified unregulated (2.5 Watt)

Physical characteristics

Width x depth x height

5.6 x 7.4 x 3.5 cm (2.2" x 2.92" x 1.37")

Mounting

In any position using 2 x M4 screws

Connector

15-pin subD female

MaxiScan 3100 - Installation Guide

45

Page 46

9 Technical characteristics

Environmental specifications

User interface

46

Operating temperature

0°C to 40°C (32°F to 104°F)

Storage temperature

-25°C to 60°C (-13°F to 140°F)

Relative humidity

10% to 90% non-condensing

Maximum ambient lighting

40 000 lux

Electrostatic discharge

± 8000 V (air discharge) ± 4000 V (contact discharge)

Shock resistance

IEC 68-2-27: 30G, 11ms, 3 axis

Vibration resistance

IEC 68-2-6: 1.5mm amplitude, 10Hz to 55Hz, 3 axis

Sealing (dust etc.)

IP65 / Nema 12

MTBF

> 20 000 hours

Power on

Red LED + 2 beeps

Good read

1 green LED flash + 1 beep (default settings)

Good read (configuration co d e s)

2 beeps

Configuration error

6 beeps

EEPROM error

3 long beeps

MaxiScan 3100 - Installation Guide

Page 47 read from a scan by OCR; it may hold reading errors

9 Technical characteristics

Reading distance (MaxiScan 3100 SR)

2.8" 2.4" 2.0" 1.6" 1.2" 0.8" 0.4" o" 0.4" 0.8" 1.2" 1.6" 2.0" 2.4" 2.8" inch

11 4.3" 10 3.9" 1.0 mm (40 mil) 9 3.5" 8 3.1" 0.5mm (20 mil) 7 2.8" 6 2.4" 5 0.2 mm (8 mil) 2.0" 4 1.6" 3 1.2" 2 0.8" 1 0.4" Scale 1:1 0 | 0" cm 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7

This chart shows the horizontal reading range for 90% contrast Code 39 barcodes read in the dark.

MaxiScan 3100 - Installation Guide 47

Page 48 read from a scan by OCR; it may hold reading errors

9 Technical characteristics

Reading distance (MaxiScan 3100 ST / ML)

5.5" 47" 3.9" 31" 24" 1.6" 0.8" 0" 0.8" 1.6" 24" 3.1" 3.9" 4.7 5.5"

| inch 34 13.4" 32 12.6" 30 11.8" 28 EAN/UPC 0.3 mm (12 mil) "a 26 10.2" 24 Een) 9.4" 20 8.7" 20 (8 mil) 7.9" 18 71" 16 6.3" 14 5.5" 12 47" 10 3.9" 8 | 3.1" 6 2.4" 4 1.6" 2 0.8" Scale 1: 2.5 0 0" om 4 12 #21 #8 6 4 2 0 2 4 6 8 10 12 14

This chart shows the horizontal reading range for 90% contrast Code 39 barcodes read in the dark.

48 MaxiScan 3100 - Installation Guide

Page 49

9 Technical characteristics

Accessories Cables

Pow er supply

Accessories

MaxiScan 3100 - Installation Guide

RS-232 C "Y" cable to connect MaxiScan 3100 to host system or PC. Includes connection for power input and can be used to set up the MaxiScan 3100 with EasySet software

0-530062-02

RS-232 cable to connect MCS box to host system or PC

0-530062-01

Cable to convert RS-232 to RS-422/485

3-510022-00

Download cable

3-514022-00

US

3-531029-08

Europe (except UK)

0-531029-02

UK

0-531029-04

Adjustable raised stand

0-531029-05

MCS connection box

0-531029-06

MCS connection box (IP version)

0-531029-07

Optical sensor input synchro

3-500029-03

49

Page 50

9 Technical characteristics

50

MaxiScan 3100 - Installation Guide