Page 41
8 Conversion cable (RS-232 C to RS-422 / 485) Host side connector
Host side - 15-pin subD female connector Pin 1
Receive / transmit data RX- / TX- (RS-485) Receive data RX- (RS-422)
2
Receive / transmit data RX- / TX- (RS-485) Transmit data TX- (RS-422)
3
Receive / transmit data RX+ / TX+ (RS-485) Receive data RX+ (RS-422)
4
Receive / transmit data RX+ / TX+ (RS-485) Transmit data TX+ (RS-422)
5
Positive synchronization input (SI+)
6
Negative synchronization input (SI-)
7
Positive synchronization output (SO+)
8
Negative synchronization output (SO-)
9
Not connected
10
Power in (7 to 25 VDC unregulated)
11
Ground
12
Reserved
13, 14, 15
MaxiScan 3100 - Installation Guide
Function
Not connected
41
Page 42
8 Conversion cable (RS-232 C to RS-422/485)
RS-422 host cable connector The user must provide the connection between the conversion cable and the host system. If this cable is long, install a resistor between pins 1 and 3. The resistor should have the characteristic impedance of the cable.
Host cable connector 15-pin subD male
RS-485 host cable connector The user must provide the connection between the conversion cable and the host system. Connect pins 1 and 2 and connect pins 3 and 4 of this cable. If the cable is long, install a resistor between pins 1 and 3. The resistor should have the characteristic impedance of the cable.
Host cable connector 15-pin subD male
42
MaxiScan 3100 - Installation Guide
Page 43
9 Technical characteristics Data (MaxiScan 3100 SR) Interface
Host system interface
- RS-232 C (standard configuration) - RS-422 (requires cable P/N 3-530062-01) - RS-485 (requires cable P/N 3-530062-01) - Current loop - passive type (requires MCS connection box P/N 0-531029-06)
Input synchronization
One hardware sync from external device One software sync from host system
Output synchronization
One hardware sync to external device One software sync to host system
Decoding
Symbologies
Codabar, Code 39, Code 93, Code 128, MSI Code, Plessey Code, EAN/UPC (including addon 2-5), Interleaved 2 of 5, Matrix 2 of 5, Standard / Industrial 2 of 5, PDF 417
S can performance
Scan rate
100 to 800 scans/second
Depth of field
See the Reading distance section below
Minimum resolution
See the Reading distance section below
Maximum code width
See the Reading distance section below
Scan angle (width)
65° minimum
Pitch
± 70°
S ke w
± 65°
Print contrast ratio
20% minimum
Light source
4 LEDs at 640 nm
Image sensor
High resolution CCD
Electrical characteristics
Power supply voltage
7 to 25 VDCfull-wave rectified unregulated (2.5 Watt)
Physical characteristics
Width x depth x height
5.6 x 7.4 x 3.5 cm (2.2" x 2.92" x 1.37")
Mounting
In any position using 2 x M4 screws
Connector
15-pin subD female
Optical characteristics
MaxiScan 3100 - Installation Guide
43
Page 44
9 Technical characteristics
Environmental specifications
User interface
44
Operating temperature
0°C to 40°C (32°F to 104°F)
Storage temperature
-25°C to 60°C (-13°F to 140°F)
Relative humidity
10% to 90% non-condensing
Maximum ambient lighting
4 000 lux
Electrostatic discharge
± 8000 V (air discharge) ± 4000 V (contact discharge)
Shock resistance
IEC 68-2-27: 30G, 11ms, 3 axis
Vibration resistance
IEC 68-2-6: 1.5mm amplitude, 10Hz to 55Hz, 3 axis
Sealing (dust etc.)
IP65 / Nema 12
MTBF
> 50 000 hours
Power on
Red LED + 2 beeps
Good read
1 green LED flash + 1 beep (default settings)
Good read (configuration co d e s)
2 beeps
Configuration error
6 beeps
EEPROM error
3 long beeps
MaxiScan 3100 - Installation Guide
Page 45
9 Technical characteristics
Data (MaxiScan 3100 ST / ML) Interface
Host system interface
- RS-232 C (standard configuration) - RS-422 (requires cable P/N 3-530062-01) - RS-485 (requires cable P/N 3-530062-01) - Current loop - passive type (requires MCS connection box P/N 0-531029-06)
Input synchronization
One hardware sync from external device One software sync from host system
Output synchronization
One hardware sync to external device One software sync to host system
Decoding
Symbologies
Codabar, Code 39, Code 93, Code 128, MSI Code, Plessey Code, EAN/UPC (including add-on 2-5), Interleaved 2 of 5, Matrix 2 of 5, Standard / Industrial 2 of 5, P D F 417
S can performance
Scan rate
200 scans/second
Depth of field
See the Reading distance section below
Minimum resolution
See the Reading distance section below
Maximum code width
See the Reading distance section below
Scan angle (width)
65° minimum
Pitch
± 70°
S ke w
± 65°
Print contrast ratio
20% minimum
Scan lines
10 (MaxiScan 3100 ML only)
Scan angle (height)
10° (MaxiScan 3100 ML only)
Optical characteristics
Light source laser diode at 660 nm Laser class: IEC Class 2. US CDRH Class II
Electrical characteristics
Power supply voltage
7 to 25 VDC full-wave rectified unregulated (2.5 Watt)
Physical characteristics
Width x depth x height
5.6 x 7.4 x 3.5 cm (2.2" x 2.92" x 1.37")
Mounting
In any position using 2 x M4 screws
Connector
15-pin subD female
MaxiScan 3100 - Installation Guide
45
Page 46
9 Technical characteristics
Environmental specifications
User interface
46
Operating temperature
0°C to 40°C (32°F to 104°F)
Storage temperature
-25°C to 60°C (-13°F to 140°F)
Relative humidity
10% to 90% non-condensing
Maximum ambient lighting
40 000 lux
Electrostatic discharge
± 8000 V (air discharge) ± 4000 V (contact discharge)
Shock resistance
IEC 68-2-27: 30G, 11ms, 3 axis
Vibration resistance
IEC 68-2-6: 1.5mm amplitude, 10Hz to 55Hz, 3 axis
Sealing (dust etc.)
IP65 / Nema 12
MTBF
> 20 000 hours
Power on
Red LED + 2 beeps
Good read
1 green LED flash + 1 beep (default settings)
Good read (configuration co d e s)
2 beeps
Configuration error
6 beeps
EEPROM error
3 long beeps
MaxiScan 3100 - Installation Guide
Page 47
9 Technical characteristics
Reading distance (MaxiScan 3100 SR)
2.8" 2.4" 2.0" 1.6" 1.2" 0.8" 0.4" o" 0.4" 0.8" 1.2" 1.6" 2.0" 2.4" 2.8" inch
11 4.3" 10 3.9" 1.0 mm (40 mil) 9 3.5" 8 3.1" 0.5mm (20 mil) 7 2.8" 6 2.4" 5 0.2 mm (8 mil) 2.0" 4 1.6" 3 1.2" 2 0.8" 1 0.4" Scale 1:1 0 | 0" cm 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7
This chart shows the horizontal reading range for 90% contrast Code 39 barcodes read in the dark.
MaxiScan 3100 - Installation Guide 47
Page 48
9 Technical characteristics
Reading distance (MaxiScan 3100 ST / ML)
5.5" 47" 3.9" 31" 24" 1.6" 0.8" 0" 0.8" 1.6" 24" 3.1" 3.9" 4.7 5.5"
| inch 34 13.4" 32 12.6" 30 11.8" 28 EAN/UPC 0.3 mm (12 mil) "a 26 10.2" 24 Een) 9.4" 20 8.7" 20 (8 mil) 7.9" 18 71" 16 6.3" 14 5.5" 12 47" 10 3.9" 8 | 3.1" 6 2.4" 4 1.6" 2 0.8" Scale 1: 2.5 0 0" om 4 12 #21 #8 6 4 2 0 2 4 6 8 10 12 14
This chart shows the horizontal reading range for 90% contrast Code 39 barcodes read in the dark.
48 MaxiScan 3100 - Installation Guide
Page 49
9 Technical characteristics
Accessories Cables
Pow er supply
Accessories
MaxiScan 3100 - Installation Guide
RS-232 C "Y" cable to connect MaxiScan 3100 to host system or PC. Includes connection for power input and can be used to set up the MaxiScan 3100 with EasySet software
0-530062-02
RS-232 cable to connect MCS box to host system or PC
0-530062-01
Cable to convert RS-232 to RS-422/485
3-510022-00
Download cable
3-514022-00
US
3-531029-08
Europe (except UK)
0-531029-02
UK
0-531029-04
Adjustable raised stand
0-531029-05
MCS connection box
0-531029-06
MCS connection box (IP version)
0-531029-07
Optical sensor input synchro
3-500029-03
49
Page 50
9 Technical characteristics
50
MaxiScan 3100 - Installation Guide