For the Trimble TSC1

Page 677

!

Unable to connect to radio

Messages

G

You selected Survey Style / Radio and pressed to connect to a radio, but timeout occurred. Check the cables, connections, and the selected radio type. Unable to connect to receiver

Connection was not successful when the survey was started. Check the cables, connections, and switches. Make sure that the receiver is turned on.

O s\

Unable to store point. No corrected positions available

You are measuring a point and pressed elapsed. Press and wait until the before enough time key appears.

Unrecognized receiver type

An incompatible receiver is connected to the Trimble Survey Controller software. Unsupported or faulty PC Card

The PC card that is inserted is not supported by the Trimble Survey Controller software or is faulty. Unsupported receiver firmware version

The software has detected old receiver firmware that is not supported. Upgrade the receiver firmware.

Trimble Survey Controller Reference Manual Volume 2

645

Page 678

G

G.3

Messages

Warning Messages yn

A warning message appears when the Trimble Survey Controller software cannot proceed. Most of these messages are for information only, but with some you must press or to continue. A new station setup is required

You have selected Measure rounds from the Survey menu after performing a survey with the current station setup. A new station setup is required before rounds can be measured. An L1 antenna is being used with an L2-capable receiver

You are using a single-frequency antenna. It is better to use a dual-frequency antenna with a dual-frequency system. Curvature and refraction applied in instrument and controller

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software has determined that the correction for curvature and refraction is being applied by both the instrument and the Trimble Survey Controller software. Change the setting in the instrument or the Trimble Survey Controller software to None. Datum grid required. Select Datum transformation and specify a datum grid or the datum transformation will be invalid

You have selected an uploaded job that uses a datum grid but the Trimble Survey Controller software cannot locate the file. Select the file now or upload it and open the job again. DTM is not valid

You are staking out a point, line, or curve. The Display Cut/Fill to DTM field in Stakeout options is set to Yes but the DTM is no longer available. (This occurs if the DTM is stored on a PC card, for example, and the card is removed).

64 6

Trimble Survey Controller Reference Manual Volume 2

Page 679

Messages

G

Geoid model and Datum grid required. Specify geoid model and datum grid, or elevations will be nulled and datum transformation invalid

You have selected an uploaded job that uses a geoid model and a datum grid but the Trimble Survey Controller software cannot locate the files. Select the files now or upload them and open the job again. Geoid model required. Select Vertical adjustment and specify a model, or elevations will be nulled

You have selected an uploaded job that uses a geoid model in the height adjustment but the Trimble Survey Controller software cannot locate the file. Select the file now or upload it and open the job again. Initialization has been lost. Initialize now?

This message can only appear during an L1 postprocessed or real-time kinematic (PPK or RTK) survey. Perform a manual initialization now or dismiss the message and initialize later. Insufficient SVs being tracked.

Lock has been lost during initialization in a postprocessed survey. (The number of satellites being tracked has fallen below the minimum.) The PP init time will be reset and initialization will resume when a minimum of four satellites are being tracked. Measure catch point without construction offsets?

m

When staking out a catch point on a road, you navigated to a catch point with construction offsets. Then you pressed with the range pole on the catch point instead of on the offset point. To stake out the offset point, press n and navigate to it.

Memory nearly full

The TSC1 memory is almost full. End the survey or current operation or the Trimble Survey Controller software will do so shortly.

Trimble Survey Controller Reference Manual Volume 2

647

Page 680

G

Messages

New base station detected, recommend the survey is restarted

During an RTK survey, radio corrections are received from a base station different from the one that the survey was started with. Any points subsequently measured or staked out will be in a different network. Trimble recommends that you restart the survey and check that corrections are being received from the original base station. To do this select Files / Review current job. No projection. Some features will not be displayed

You have chosen to display the Current job map but have not defined a projection for the job. As a result, WGS-84 points such as the base station cannot be displayed on the map. Only grid points, or points that can be converted into grid points, can be displayed. No DTM selected

You are staking out a point, line, or curve. The Display cut/fill to DTM field in the Stakeout options is set to Yes but no DTM is selected.

é y

Please confirm: Not all points have been observed. End observations on this face?

You pressed during a rounds survey before all points have been observed on the current face. Press to confirm that you want to end observations for that face. Observation is on the wrong face

You are trying to make an observation in a rounds survey on the wrong face. Change the face on the instrument and observe again.

~

Please confirm: Remove all points from list

You pressed from the Stakeout list. Press you want to remove all the points.

y to confirm that

Point does not exist. Provide coordinates at processing time

You have started the base receiver in a postprocessed survey and the point name is not in the database. Provide the coordinates of this point when postprocessing the data. 64 8

Trimble Survey Controller Reference Manual Volume 2

Page 681

Messages

G

Poor geometry

You are performing an initialized RTK survey using a Series 4000 receiver as a rover. The PDOP value exceeds the PDOP mask and although another satellite is available, it is not yet in the solution. (This can be a new satellite or one that the receiver has not tracked for a short period.) High PDOP means that the receiver cannot use the new satellite in the solution. You see the following options, depending on the equipment: Go static, Static initialize, Roving initialize, Continue anyway. If you select Go static, the system attempts to use the extra satellite to make a better estimate of its position. When the system is static, it uses RDOP instead of PDOP. RDOP decreases with time: if the system takes longer than 30-45 seconds, the PDOP of the initialized satellites is so high that it cannot include the extra satellite. Wait until the constellation improves. If you select Static initialize, you can reinitialize using a known point, new point, or initializer plate / bar, depending on the equipment. If your receiver has On-The-Fly capability and you select Roving initialize, an OTF initialization is performed. If you select Continue anyway, you can continue to survey with the high PDOP. The system will not use the extra satellites (that are being tracked but that are not in the solution) until the PDOP of the initialized satellites drops below six, or until you go static by recording a point at a later time. Point name error. Some points have not been transferred

You are transferring points to a TDS device using the Unchanged option for the point names and some of the points have not been transferred. A point will only be transferred if the point name is less than eight characters long and contains numeric characters only.

Trimble Survey Controller Reference Manual Volume 2

649

Page 682

G

Messages

PPM applied in instrument and controller

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software has determined that the correction for PPM is being applied by both the instrument and the Trimble Survey Controller software. Change the setting in the instrument or the Trimble Survey Controller software to null. Prism constant applied in instrument and controller

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software has determined that the prism constant correction is being applied by both the instrument and the Trimble Survey Controller software. Change the setting in the instrument or the Trimble Survey Controller software to zero. Receiver has stopped logging data

A GPS data logging survey (to the receiver) was running and the receiver has unexpectedly stopped logging. Receiver is currently busy

Part of the system, for example Radio configuration, is communicating with the receiver. Exit the screen that is communicating with the receiver.

y

Receiver is still initialized. Discard current initialization?

Press to confirm that you want to discard the initialization.

Receiver port cannot be used. Update stakeout external display settings

You are trying to start a survey with the external display option enabled and have specified an invalid receiver port. Select Stakeout in your Survey Style and set the External display fields correctly.

65 0

Trimble Survey Controller Reference Manual Volume 2

Page 683

Messages

Specified number of rounds have not been completed. Continue?

G yn

You have ended a rounds survey before the number of rounds specified in the Options screen have been completed. Press to confirm that you want to end the current rounds session, or press to continue observing rounds. Style changes will not apply to current survey

You have chosen a Survey Style that is the same as the one used by the survey that is running. Survey has been stopped. Receiver memory is full

This message can occur when GPS data is being logged to the receiver. The receiver memory is so full that the survey has been ended. Survey has ended. Controller memory is full

This message can occur when GPS data is being logged to the TSC1 data collector. The TSC1 memory is so full that the survey has been ended. Turn to zero selected. Do not use Next or Menu in stakeout, communication errors will occur.

You are configuring a SET (Extended) conventional Survey Style and the Stakeout turn to zero field is set to Yes. This option puts the SET instrument into a special mode where standard commands do not work. When staking out, do not use the and keys to access other menus - communication errors will result. Exit the stakeout screen by pressing before using the and keys.

=

N M N M

Unused observations have been deleted

You exited out of the Point details screen after setting the Use field to No for one or more observations.

Trimble Survey Controller Reference Manual Volume 2

651

Page 684

G

G.4

Messages

Status Line Messages A status line message alerts you to information that requires attention. A status line message generally remains on the screen until you or the Trimble Survey Controller software resolve the situation. Cannot check corrections

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software cannot determine whether the corrections for prism constant, PPM, and curvature and refraction are being applied by both the instrument and the Trimble Survey Controller software. Check that the corrections are only applied once. Cannot check curvature & refraction

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software cannot check if the correction for curvature and refraction is being applied by both the instrument and the Trimble Survey Controller software. Check that the correction is only applied once. Cannot check PPM

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software cannot determine whether the correction for PPM is being applied by both the instrument and the Trimble Survey Controller software. Check that the correction is only applied once. Cannot check prism constant

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software cannot determine if the prism constant correction is being applied by both the instrument and the Trimble Survey Controller software. Check that the correction is only applied once.

65 2

Trimble Survey Controller Reference Manual Volume 2