Page 685

Messages

G

Computing position, please wait

The Trimble Survey Controller software is starting a survey. It cannot continue until the receiver has computed a position based on the satellites it is tracking. This can take up to 30 seconds. Continuous topo: poor precisions

The precisions set under Continuous topo in the Survey Style cannot be met. No points are stored while this message is flashing. Controller battery is dead

The internal battery of the TSC1 data collector is flat. There is just enough power left to display this message. Recharge the battery. Corrections checked

This message appears when Station setup is selected in a conventional survey. It means that the Trimble Survey Controller software has checked that the corrections for prism constant, PPM, and curvature and refraction are not being applied by both the instrument and the Trimble Survey Controller software. EDM error

The EDM signal is not strong enough to give a distance measurement. Make sure that the target is not obstructed and that the conventional instrument is functioning correctly. First face completed

You have completed observations on the first face during a rounds survey. High RMS

RMS is an indicator of the quality of GPS phase measurements. This message appears during an RTK survey. If measuring a point, you probably wobbled the pole during the observation. If roving, you could be in a high multipath environment or the last initialization could be bad. Trimble Survey Controller Reference Manual Volume 2

653

Page 686

G

Messages

Initialization in 30s

This message can appear during a Real-Time Kinematic (RTK) or Postprocessed Kinematic survey. It is an estimate only. Initialization requires 5 L2 SVs

This message can appear during a Real-Time Kinematic (RTK) or Postprocessed Kinematic survey with OTF initialization capabilities. Wait until there are enough satellites being tracked on both the L1and the L2 frequencies to continue, or move to a place where there is a better view of the sky. Initializing survey, please wait

RTK survey with OTF initialization. This is displayed only when no estimate of time to init is available. Instrument error

The Trimble Survey Controller is unable to communicate with the instrument. Low base battery

The base receiver battery is low. This message appears at the rover receiver when it is in RTK mode during a real-time survey, a real-time and infill survey, or a real-time and datalogging survey. Low base memory

The available memory in the base receiver is getting low. This message appears at the rover receiver when it is in RTK mode during a real-time survey, a real-time and infill survey, or a real-time and datalogging survey. Low Controller battery

The internal battery of the TSC1 data collector is getting low. Remove and recharge it. 65 4

Trimble Survey Controller Reference Manual Volume 2

Page 687

Messages

G

Low receiver battery

The batteries in the rover receiver are getting low. Low receiver memory

The rover receiver is logging GPS data and its available memory is getting low. End the survey soon. Main memory nearly full

The internal memory of the TSC1 data collector is getting full. Less than 30 KB of data space remains. End the survey soon. Measuring point: poor precisions

The precisions set under Point measurement in the Survey Style cannot be met. No automatic measurement takes place while this message is flashing. No target

The target was not located during the search. Re-point the instrument and try the search again. PC card memory nearly full

The PC card memory is getting full. Less than 30 KB of data space remains. End the survey soon. Poor PDOP

The current PDOP is greater than the PDOP mask set under Rover options in the Survey Style. Radio link down

Radio corrections have stopped being received during a real-time survey.

Trimble Survey Controller Reference Manual Volume 2

655

Page 688

G

Messages

Radio link up

Radio corrections have returned after being down during a real-time and infill survey. Select Stop pp infill and continue with a real-time survey. Setting clock, please wait

Starting a survey. The survey cannot start until the receiver has set its time from the SVs that it is tracking. This can take up to 30 seconds. Target detected

The target has been located (when the instrument is in servo mode). Target locked

The target has been located and tracking has been locked (when the instrument is in robotic mode). The first point in the resection was unable to be used as the backsight

The first point observed in the resection could not be used as the backsight because there are no horizontal coordinates for it. Alternatively, you changed the Use field in the Resection point screen to V or Off. Tilt error

The conventional instrument is not level and is beyond the range of its compensators. Level the instrument and perform a station setup. Waiting for info from base

The Trimble Survey Controller software is starting a real-time survey, and is waiting for details of the base station across the radio link. If this persists for more than ten seconds, check radio settings, cabling, and base output.

65 6

Trimble Survey Controller Reference Manual Volume 2

Page 689

Messages

G

Waiting for radio link

The Trimble Survey Controller software is starting a real-time survey, and is waiting for CMR or RTCM corrections from the base receiver across the radio link. If this persists, check radio settings, cabling, and base output. It is possible that you are trying to start a rover survey while connected to a receiver that is operating as a base (and broadcasting corrections). End the survey and try again. Waiting for satellites

Starting a survey or during a survey. The survey cannot continue until the receiver has got lock on four or more satellites.

G.5

O=

Field Error Messages A field error message tells you that there is an invalid entry in a field. Press or and then enter a correct value. <Field name>: A value is required for this field

This field requires a value before continuing. You left it as null (?). <Field name>: Out of range <low value> to <high value>

This fields requires numerical input within the displayed ranges. <Field name>: Invalid time

The value entered into a time field is not in the correct time format (for example, MM:HH:SS or 10m5s). <Field name>: Invalid date

The value entered into a date field is not in the correct date format (for example, MM/DD/YY). <Field name>: Invalid units

The units entered in this field do not correspond to any in the system.

Trimble Survey Controller Reference Manual Volume 2

657

Page 690

G

G.6

Messages

Other Messages These messages appear when you try to delete a job that has not been downloaded or the status of the receiver has changed. Confirm deletion: Job has not been exported

When you attempt to delete a job, this message warns that the job has not been downloaded. If you delete the job, it goes on to the Undelete job list and will eventually be completely deleted. Error: Total station is not responding. Attempting to reconnect

The Trimble Survey Controller software is trying to connect to the instrument. It should do this within a few seconds. If it does not, check all cables and connections. Initialization change: Initialization has been gained

Initialization has been gained. This applies to an RTK, RTK & infill, or PP kinematic survey. Initialization change: Initialization has been lost

Initialization has been lost. This applies to an RTK, RTK & infill, or PP kinematic survey. Please wait. Connecting to receiver

The Trimble Survey Controller software is trying to connect to a receiver. It should do this within a few seconds. If it does not, check all cables, connections, and switches. Please wait. Instrument turning

ç

Indicates that the instrument is about to change face. Only applies to servo and robotic instruments when the softkey is selected. Searching...

Indicates that the instrument is conducting a search for the target.

65 8