Page 669
APPENDIX
G G
Messages In this chapter: ■
Introduction
■
Error messages
■
Warning messages
■
Status line messages
■
Field error messages
■
Other messages
Page 670
G
G.1
Messages
Introduction This appendix lists the messages that can appear on a TSC1 data collector. It provides an alphabetic list for each of the following:
G.2
•
Error messages
•
Warning messages
•
Status line messages
•
Field error messages
•
Other messages
Error Messages
O\=
An error message appears when the Trimble Survey Controller software cannot proceed with a function. To acknowledge an error message, press , , , or the key that is indicated. Then correct the problem. Abnormal shutdown
You did not end the previous survey correctly before turning off the Trimble Survey Controller software. Area calculation has failed. Check Cogo settings
The area calculation has failed. Make sure that the value in the Distances field in the Cogo settings screen is correct. Area perimeter crosses over. Calculation is invalid
The area calculation includes a set of points for which the perimeter lines cross. At least three points are required to calculate an area
You have selected less than three points for area computation.
63 8
Trimble Survey Controller Reference Manual Volume 2
Page 671
Messages
G
Calculator expression too complex
You have entered more than ten nested functions when using the Trimble Survey Controller software’s in-field calculator. Calculator syntax error
You have entered an invalid formula when using the Trimble Survey Controller software’s in-field calculator. Check the order of the numbers and the operators. Cannot copy roads while receiver is in use
You have attempted to copy a road while the Trimble Survey Controller software is communicating with the receiver. Close the windows that are communicating with the receiver and try again. Cannot go static until 1 epoch has elapsed
The receiver must be allowed to go into roving mode before it can go static again. Cannot perform this operation. End the survey first
You have attempted to change the current job while a survey is running. End the survey and try again. Cannot perform this operation. Job currently in use
You have attempted to change the current job while the Trimble Survey Controller software is doing another operation. Cannot perform this operation. Use the NEXT key to close other job windows
You have attempted to change the current job while other windows that need it are open. Close the other windows and try again. Cannot perform this operation. Receiver is currently measuring
You have attempted to measure points while some other window is doing this.
Trimble Survey Controller Reference Manual Volume 2
639
Page 672
G
Messages
Cannot perform this operation. The comms port is being used
You have attempted to start a survey, configure a radio, or do data transfer while one of these is operational already. Communications error
A general communications error has occurred. Check cables, connections, and switches. Check that the output on the receiver port has not been disabled. Connection failed. Receiver is transmitting on external port.
You are trying to configure a radio that is attached to a receiver set up as a base. Select End survey from the Survey menu and try again. File cannot be modified
You have tried to delete or edit a system file. File information not available from this receiver type
GPS file listings are only provided by 4600LS receivers and GPS Total Station 4800 or 4700 receivers. GPS receiver card not supported
You have inserted a GPS receiver PC card, such as the Pathfinder Card™. Insufficient memory in the controller
You are logging data to the TSC1 data collector, and there is less than 20 KB of logging space available. You cannot start the survey. Insufficient memory in the receiver
You are logging data to the receiver, and there is less than six minutes of logging space available. You cannot start the survey.
64 0
Trimble Survey Controller Reference Manual Volume 2
Page 673
Messages
G
Insufficient memory to perform the operation
There is not enough memory left to perform the operation. Close some windows and try again. Invalid geoid file. No vertical adjustment will be installed
You have selected a geoid model that is not in a valid format. Need at least one 3D point to perform a calibration
If no projection or datum transformation is specified, define at least one grid point with defined horizontal and vertical coordinates before calculating a calibration. No result for defined intersection
A Cogo intersection calculation has failed due to limitations in the standard ellipsoid formulas. For example, the intersection fails if two azimuths only converge by a small amount or if two points are too far apart on the ellipsoid. No DTM selected
You are staking out a point, line, or curve. The Display Cut/Fill to DTM field in Stakeout options is set to Yes but no DTM is selected. Number of rounds: Out of range 1 to 20
You have entered a number outside the range of 1 to 20 in the Number of rounds field. Enter the number of rounds to be observed, between 1 and 20. Observation does not exist. Field cannot be changed
You are trying to set the Use field to Yes for an observation that was skipped in a rounds survey. One circle is contained within the other
A Cogo Dist-dist intersection calculation has failed. The two arcs do not intersect because of containment.
Trimble Survey Controller Reference Manual Volume 2
641
Page 674
G
Messages
Out of memory. Close down some windows and try again
Too many next-window windows are open. The current operation needs memory before it can start. Parallels are equal
When you key in a Lambert 2 Parallel projection, the orientation values must be different. PC Card: <error number>
A PC card has a hardware or software error, with the number <error number>. Report this number to your local dealer. PC Card needs formatting
You have inserted an unformatted PC card. Format it on the office computer and reinsert it. Radio configuration specifies an invalid receiver port
The configuration specifies a non-existent port on the receiver. Radio configuration specifies receiver port currently used by controller
The TSC1 data collector is using the port set for the radio. Select the Radios option in the Survey Style and change the port setting. Receiver does not support the Clarion radio
The receiver does not have a Clarion radio driver installed. Receiver does not support data logging
The receiver does not have internal memory. Receiver does not support data logging to the controller
The receiver does not have the real-time data output option installed. It cannot store data while it is doing an RTK survey.
64 2
Trimble Survey Controller Reference Manual Volume 2
Page 675
Messages
G
Receiver does not support RTCM
The receiver does not have RTCM capability, or it does not have the necessary options installed. Receiver does not support RTK
The receiver does not have the RTK option installed.
a
Receiver is in an unknown state
This message should clear after a few seconds. If it does not, press to end the survey, then start another survey. Receiver is not responding. Attempting to reconnect a
A general communications error has occurred. Check cables, connections, and switches. When the receiver reconnects, the message disappears. Otherwise press to end the survey. Resection calculation has failed. Check the target point data and geometry
The resection calculation has failed and coordinates may not be displayed. Change the setting in the Use field in the Resection point screen and check the coordinates of the point observed to. Alternatively, check the geometry of the observed points. They should not lie on a circle. Start station: Station does not exist
You are trying to compute a traverse and the point name you have entered for the start station does not exist, or has no observations from it. Station setup not defined
You are trying to turn a servo or robotic instrument to a point where the station setup has not been defined.
Trimble Survey Controller Reference Manual Volume 2
643
Page 676
G
Messages
The two azimuths are parallel
You are using the Cogo function with the Brng-brng intersection method. Where two azimuths cannot intersect because they are parallel. The two circles are concentric
You are using the Cogo function with the Dist-dist intersection method. The two distances emanate from the same point. Too close to equator
When you key in a Lambert 1 Parallel or Lambert 2 Parallel projection, the orientation values must be greater than 10° north or south of the equator. Too many calibration points
A calibration can be calculated with up to 20 points. This message appears when point 21 is added. Too many files already exist. Cannot create file
The Trimble Survey Controller software lets you use 100 files of any one type. You can have up to 100 job files and 100 language files, for example. (This figure includes recoverable deleted files.) Too many observations for a resection calculation
There are more than forty observations in the resection calculation. Delete some. Total station is not responding. Attempting to reconnect
The Trimble Survey Controller software has lost communications with the instrument. Check cables, connections and the power supply to the instrument. When the instrument reconnects, the message disappears.
64 4