Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 74 of 83

Trimble Survey Controller Reference Manual: Working with Road Templates

Pages 659 to 668 of 744, from Trimble Survey Controller Reference Manual

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSC1

Page 659

APPENDIX

F F

Working with Road Templates In this chapter: ■

Introduction

■

Interpolating between templates

■

Applying superelevation values

■

Pivots

Page 660

F

F.1

Working with Road Templates

Introduction This appendix describes how the Trimble Survey Controller software: • interpolates between templates

• applies superelevation values to elements in a template

• works with pivots

It provides some background to Key In Roads, page 543.

F.2

Interpolating Between Templates This section shows how the Trimble Survey Controller software interpolates between templates when consecutive templates have:

62 8

• an equal number of design elements

• a different number of design elements

• different side slopes

Trimble Survey Controller Reference Manual Volume 2

Page 661

Working with Road Templates

F

When Templates Have an Equal Number of Design Elements

F.2.1

If consecutive templates have an equal number of design line elements, the Trimble Survey Controller software interpolates from each element in the first template to its equivalent in the next template. In Figure F.1, for example, the first element of the template at station 0+100 has a cross fall of –2% and an offset of 4.0 m. The next assigned template is at station 0+400, where the equivalent element has a cross fall of –5% and an offset of 7.0 m. The values for stations 0+200 and 0+300 are interpolated as shown to provide an even grading from station 0+100 to 0+400. 0+400 7 m, –5% 6 m, –4.33%

0+100

5 m, –3.40% 4 m, –2%

Figure F.1

^

Interpolating between templates – equal number of design line elements

Note – Interpolation will only take place if the offset being staked is selected from the list or selected using the softkey. For more information, see Chapter 18, Roading, page 428.

Trimble Survey Controller Reference Manual Volume 2

629

Page 662

F F.2.2

Working with Road Templates

When Templates Have a Different Number of Design Elements If one template has more design line elements than the next template, the Trimble Survey Controller software adds an appropriate number of zero-length elements to the template with fewer elements. These zerolength elements are added to the end of the last element, before the side slope element begins. This creates an equal number of elements, and the Trimble Survey Controller software then interpolates as described in When Templates Have an Equal Number of Design Elements, page 629. In Figure F.2, for example, the Trimble Survey Controller software added the zero-length element ‘3’. 1

1

3 2

2 3

Figure F.2

63 0

Interpolating between templates – different number of design line elements

Trimble Survey Controller Reference Manual Volume 2

Page 663

Working with Road Templates F.2.3

F

Template Application The following section explains how placement and transition between templates control the road definition. Template B

Template A

Template A

0 m 20 m

40 m

70 m

Template A

90 m

<None>

<Interpolate>

120 m

150 m

Template B

Template B Figure F.3

Applying templates

Right-hand side of the road Template A is assigned to stations 0 to 20 m. The road makes a transition from Template A at station 20 m to Template B at station 70 m. Because a template must be assigned at station 40 m on the left-hand side, to maintain correct interpolation the system template <Interpolate> must be assigned to the right-hand side of the road at station 40 m. To correctly represent the gap between stations 70 to 90 m, the system template <None> is assigned at a nominal distance after station 70 m (for example, 70.005 m). To complete the right-hand side of the road, Template B is assigned from station 90 to 150 m.

Trimble Survey Controller Reference Manual Volume 2

631

Page 664

F

Working with Road Templates

Left-hand side of the road Template A is assigned from station 0 to 40 m. The road makes a transition from Template A at station 40 m to Template B at station 70 m. To correctly represent the design, Template A is assigned a nominal distance after station 120 m (for example, 120.005 m) to 150 m. Assign the templates at the specified stations as shown in table F–1. Table F.1

Assigning Templates

Station

Left template

Right template

0.000

Template A

Template A

20.000

Template A

Template A

40.000

Template A

<Interpolate>

70.000

Template B

Template B

70.005

Template B

<None>

90.000

Template B

Template B

120.000

Template B

Template B

120.005

Template A

Template B

Notes

63 2

•

To best represent the road design, you can add zero length template elements yourself. Do this when you construct the template. For more information, see Keying In Elements, page 556.

•

No interpolation occurs between a <None> template and a userdefined template.

•

Superelevation and widening are applied before interpolation between templates occurs.

•

The <Interpolate> template can only be assigned between valid user-defined templates

Trimble Survey Controller Reference Manual Volume 2

Page 665

Working with Road Templates F.2.4

F

When Side Slopes are Different If consecutive templates have side slopes of different values, the Trimble Survey Controller software bases the interpolation on the difference between the slope values. For example, if the side slope at station 6+000 is 1:2 and at station 10+000 it is 1:4, the side slope at station 8+000 will be 1:3.

F.3

Applying Superelevation Values This section shows how the Trimble Survey Controller software applies superelevation values to elements in a template. The first element with the Apply superelevation field set to Yes determines the superelevation applied to each element to be superelevated. The amount of superelevation that the Trimble Survey Controller software applies is determined by the difference between the first template element and the superelevation value that you specify. The same amount of superelevation is applied to each element that has the Superelevation field set to Yes. For example, if the first element that superelevation is applied to in a template has a cross fall of –2%, and the superelevation value specifies that the superelevation at that station is to be +6%, then 8% is added to the cross fall of each superelevated element in that template.

Trimble Survey Controller Reference Manual Volume 2

633

Page 666

F

Working with Road Templates

Figure F.4 shows, in cross-section, elements of a template before and after superelevation values are applied. Before superelevation is applied

–2% Cross fall –5% Cross fall 0% Cross fall

After superelevation is applied

3% Cross fall 6% Cross fall

Superelevation is applied to these elements Figure F.4

63 4

Applying superelevation

Trimble Survey Controller Reference Manual Volume 2

0% Cross fall

Page 667

Working with Road Templates

F.4

F

Pivots This section shows the three pivot settings (Crown, Right, and Left) that are available in the Trimble Survey Controller software. Figure F.5 shows a Crown pivot. Super elevated

Normal

Figure F.5

Pivot crown option

Figure F.6 shows a Right pivot.

Maximum offset of the last element with Superelevation set to Yes

Figure F.6

Pivot right option

Trimble Survey Controller Reference Manual Volume 2

635

Page 668

F

Working with Road Templates

Figure F.7 shows a Left pivot.

Maximum offset of the last element with Superelevation set to Yes Figure F.7

63 6

Pivot left option

Trimble Survey Controller Reference Manual Volume 2