Conventional Instrument Settings Introduction This appendix lists the settings for different conventional instruments. The Trimble Survey Controller software supports the instruments listed and other instruments that are compatible. Notes: •
The conventional instrument should always display the Measure screen when connected to the Trimble Survey Controller. Some instruments (for example, the Leica) cannot communicate to external devices when they are not in the measure screen.
•
Before connecting the TSC1 data collector to a Leica or Geodimeter instrument, you must select an appropriate Survey Style first. This Survey Style must specify the correct type of instrument. Connect the instrument and select Station setup. Failure to follow this procedure will result in communication errors. If this occurs, power the instrument down and try again.
Page 652
E
Conventional Instrument Settings
This is not a problem with robotic instruments connected remotely through a radio modem. •
When using a Leica instrument in reflectorless mode, set the EDM precision to Instrument default in the Survey Style.
•
The Nikon cable looks identical to the Topcon and Sokkia cables, but the pin outputs are different. These cables are not interchangeable.
•
Most Nikon instruments support the Set (Basic) commands, so in addition to using the Nikon instrument type you can also specify Set (Basic) as the instrument in the Survey Style for use with Nikon instruments.
•
When measuring a point using a Geodimeter 420 instrument, on the Trimble Survey press A/M on the instrument then Controller.
•
To use the Trimble Survey Controller software with a Geodimeter 600 instrument in Robotic mode, you must have the third party interface option turned on in the instrument. Please see your Spectra/Geodimeter service center for more details on how to obtain the third party interface password.
•
Do not use the following units when using a Pentax instrument: Mils and Feet/inches.
•
The Trimble Survey Controller software automatically sets the data bits based on the parity. When the parity is None the data bits is 8. When the data bits is Odd or Even, the data bits is 7.
m
For additional information on using a conventional instrument with the Trimble Survey Controller software, see the Trimble Survey Controller Release Notes If you are using an instrument that is not listed, try using the Survey Style for a similar instrument, and configure the appropriate settings on the instrument, as specified in Table E-1.
62 0
Trimble Survey Controller Reference Manual Volume 2
Page 653
Conventional Instrument Settings Table E.1
Conventional Instrument Settings
Make and Model
Trimble Survey Controller configuration
Cable connected to TSC1 DB9 cable
E
Conventional instrument setting
Sokkia SET 3B SET 3C II
Baud 1200 Hirose to DB9 / TSC1 Parity None Lemo HA VA status rate Never
Setting the Checksum to Yes is recommended.
Baud 1200 Hirose to DB9 / TSC1 Parity Even Lemo HA VA status rate Never
Set minimum distance to OFF.
SET 5W SET 5F Power set 3100 Topcon GTS-500 GTS-700
No special settings.
GTS-701 GTS-711D GMT-100
Select Parameters / Comms and set the CR/LF option to OFF. Turn off the minimum distance setting.
GTS-311
Select Parameters / Comms and set the CR/LF option to OFF.
GTS-312 GTS-211D
No special settings.
Trimble Survey Controller Reference Manual Volume 2
621
Page 654
E
Conventional Instrument Settings
Table E.1
Conventional Instrument Settings (Continued)
Make and Model
Trimble Survey Controller configuration
Cable connected to TSC1 DB9 cable
Conventional instrument setting
Zeiss Elta 2
Baud 1200 Zeiss 5P connector to Parity Odd DB9 / TSC1 Lemo HA VA status rate Never
Elta 3 Elta 4 Rec Elta 15
Baud 4800 Parity Odd HA VA status rate 1s
R Series
Baud 9600 Parity None HA VA status rate 1s
S Series
Not supported
62 2
Zeiss 8P connector to DB9 / TSC1 Lemo
Trimble Survey Controller Reference Manual Volume 2
No special settings.
Do not use Mils as the angular units. Set data record format to Rec 500. Set the protocol to REC E and turn off recording.
Page 655
Conventional Instrument Settings
E
Table E.1
Conventional Instrument Settings (Continued)
Make and Model
Trimble Survey Controller configuration
Cable connected to TSC1 DB9 cable
Conventional instrument setting
TC300
Baud 19200 Parity Even HA VA status rate 2s
Leica 5-pin zero-shell Lemo to DB9 / TSC1 Lemo
No special settings.
TC500
Baud 2400 Parity Even HA VA status rate 2s
Leica
TC800 TC805 T1000 (6 button)
Baud 2400 Parity Even HA VA status rate Never
T1000 (14 button)
Baud 2400 Parity Even HA VA status rate 2s
TC1100 TC1100 Servo (GSI)
Baud 9600 Parity Even HA VA status rate 2s
TC1100 Servo (Geocom)
Baud 19200 Parity None HA VA status rate Never
TC1100 Robotics (Geocom) TC1600 TC2000 TC2002
Set the instrument communications format to T1000 and output to GRE.
Set the RCS communications mode to off. Ensure that the instrument is in Measurement mode.
Leica Y-Cable with power supply to DB9 / TSC1 Lemo Baud 2400 Parity Even HA VA status rate 2s
Leica 5-pin zero-shell Lemo to DB9 / TSC1 Lemo
Set the RCS communications mode to on. Ensure that the instrument is in Measurement mode.
No special settings. On the instrument select SET MODE, then 75. No special settings.
Trimble Survey Controller Reference Manual Volume 2
623
Page 656
E
Conventional Instrument Settings
Table E.1
Conventional Instrument Settings (Continued)
Make and Model
Trimble Survey Controller configuration
Cable connected to TSC1 DB9 cable
Conventional instrument setting
Spectra Precision (Geotronics) 420
Baud 1200 Geotronics DB9 Y-cable Select the Standard table Parity Even with power supply to (table number 0). HA VA status rate Never DB9 / TSC1 Lemo Set F79 to 62.
520
Baud 1200 Parity None HA VA status rate Never Geotronics Hirose to
610 620
DB9 / TSC1 Lemo
640 500/600 Servo
Baud 9600 Geotronics Y-cable with Parity None HA VA status rate Never power supply to DB9 / TSC1 Lemo
Select the Standard table (table number 0). Set F79 to 62. Select RPU Manual or Automatic.
600 Robotics
Select the Standard table (table number 0). Set F79 to 62. Select PRU Remote.
4000 Servo
Select the Standard table (table number 0). Set F79 to 62.
62 4
Trimble Survey Controller Reference Manual Volume 2
Page 657
Conventional Instrument Settings
E
Table E.1
Conventional Instrument Settings (Continued)
Make and Model
Trimble Survey Controller configuration
Cable connected to TSC1 DB9 cable
Conventional instrument setting
Baud 1200 Parity None HA VA status rate 2s
Hirose to DB9 / TSC1 Lemo
No special settings.
Nikon DTM-310 DTM-420 DTM-450 DTM-520 DTM-530 DTM-800
Baud 1200 Parity None HA VA status rate Never
Use Instrument type Set (Basic). The 800’s do not support the Nikon format.
Pentax PCS-325
Baud 1200 Parity None HA VA status rate 1s
Hirose to DB9 / TSC1 Lemo
Configure the port parameters as follows: Xon/Xoff = No Command set = Nil
Trimble Survey Controller Reference Manual Volume 2
625
Page 658
E
62 6
Conventional Instrument Settings