Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 83

Trimble Survey Controller Reference Manual: The TSC1 Data Collector, pages 49 to 56

Pages 49 to 56 of 744, from Trimble Survey Controller Reference Manual

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSC1

Page 49

The TSC1 Data Collector

2

Table 2.2 shows the estimated time available when using a dual-frequency receiver to track six satellites with a logging/epoch interval of five seconds. Table 2.2

Data logging time available

Memory

Available memory

Time available

2 MB

1.795 MB

8 h 34 m

To calculate the time available, first calculate the number of bytes required to store one record: 33 + (n x 30) for a single-frequency (L1) receiver 33 + (n x 43) for a dual-frequency (L1/L2) receiver where n is the number of satellites available. To see how many bytes are left in the TSC1 memory, select Configuration / Controller / Hardware. Look at the value in the Memory free field to see how much memory is left. To calculate the time remaining, use the formula: Bytes free Time = x logging interval Bytes stored per epoch For example, if a TSC1 with 1.795 MB free is logging L1/L2 data with a logging interval of fifteen seconds, and tracking six satellites, the time remaining is: Number of bytes per record = 33 + (6 x 43) = 291 Time =

1,795,000 291

B x

15 sec = 92,526 seconds = 25 h 42 min

Tip – To log data for longer periods than this, increase the GPS logging intervals or use a PC card to increase the TSC1 memory capacity. For more information about changing the logging interval, see Logging device, page 128.

Trimble Survey Controller Reference Manual Volume 1

19

Page 50

2

The TSC1 Data Collector

2.6

Operating Temperature and Humidity Ranges The TSC1 data collector operates in temperatures of between –30°C (–22°F) and +65°C (149°F) and in environments of up to 100% noncondensing humidity. To store the TSC1, transfer any data and remove the battery. Store at a temperature of between –30°C (–22°F) and +80°C (+176°F). The data collector withstands wind-driven rain and dust. Table 2.3 lists the specifications of the TSC1 data collector.

20

Table 2.3

TSC1 physical specifications

Property

Specification

Size

266 mm x 116 mm x 42 mm

Weight

800 g (28 oz)

Power

<1 W

Operating temperature from –30°C to +65°C

Storage temperature from –30°C to +80°C

Humidity

100 % non-condensing

Casing

UV-resistant plastic, fully sealed and buoyant

Memory

2 MB internal flash memory with PC card expansion capacity

Communications

2 x RS232 serial ports

Display

240 x 200 graphics LCD display with backlight

Trimble Survey Controller Reference Manual Volume 1

Page 51

The TSC1 Data Collector

2.7

2

Power Sources The TSC1 data collector is supplied with a Lithium-ion battery (part number 29518). This is a 7.4 V 1.3 AH rechargeable battery. The TSC1 is also supplied with a 9 V battery adaptor. Use this if you want to use a 9 V battery to power the unit. The operation time of a standard 9 V battery is approximately two to three hours. For more information, see Using the 9 V TSC1 Battery Adaptor, page 30.

C

Warning – If using Lithium-ion batteries, only insert a Trimble-approved Lithium-ion battery into the TSC1 internal battery compartment. A Lithium-ion battery not approved by Trimble can damage the unit.

The TSC1 relies on the internal battery when it is not connected to a receiver supplying power or to any other power source.

2.7.1

Battery Status The status line displays the status of both the TSC1 battery and of any external power source. For a list of items that appear in the status line, see Table 3.3 on page 42. You can also view the TSC1 data collector power status by selecting Configuration / Controller / Hardware. The Internal battery field shows how much power remains, and indicates whether the internal battery is: • being used

• not being used

• charging

Note – For information about the receiver power status, see Receiver Status, page 354.

Trimble Survey Controller Reference Manual Volume 1

21

Page 52

2 2.7.2

The TSC1 Data Collector

Low Battery Warnings When the Trimble Survey Controller software detects that the internal battery voltage is low, the following message flashes in the status line: Low Controller battery

This usually appears when the voltage level has dropped to about 10%. You can continue to use the TSC1 data collector for a short period, but replace or recharge the battery as soon as possible. When the Trimble Survey Controller software detects that the main battery voltage is so low that it cannot function, the following message flashes in the status line: Controller battery is dead

The TSC1 turns off, and you must replace or recharge the battery. Note – The TSC1 data collector can work without a charged internal battery if it is connected to another power source. Even when the internal battery can no longer function, no data is lost. This is because data in the TSC1 is stored in flash memory (see page 17). The only item that may change is the Time/date setting. The Trimble Survey Controller software automatically corrects this when you start the next GPS survey. If the TSC1 receives power from another source within 30 seconds the Time/date setting is not affected.

22

Trimble Survey Controller Reference Manual Volume 1

Page 53

The TSC1 Data Collector

2.8

2

Recharging the TSC1 Battery To recharge the Lithium-ion battery of the TSC1data collector, do one of the following: •

Connect the TSC1 to the AC adaptor.

•

Connect the TSC1 to an Office Support Module charger.

•

Remove the battery and charge it in the (optional) battery charger.

•

Connect the TSC1 to a receiver with an external power source, or directly to a camcorder battery, and change the Low voltage charging enabled setting to Yes.

The battery recharges fully in approximately three hours. Note – Recharge Lithium-ion batteries at a temperature of between 0°C and 50°C. If the temperature exceeds this range while the battery is being charged, a red temperature warning light (labeled TEMP) comes on. Charging stops until the temperature returns to the required range.

2.8.1

Using the AC Adaptor To recharge the TSC1 battery using the AC adaptor: 1.

Connect the TSC1 data collector to the AC adaptor using the TSC1 to DB9/power supply Y-cable (part number 32345).

2.

Insert the jack plug on the AC adaptor into the socket on the Y-cable, and the Lemo connector into the TSC1.

3.

Plug the AC adaptor into the main power.

For more information about the AC adaptor, see page 28.

Trimble Survey Controller Reference Manual Volume 1

23

Page 54

2 2.8.2

The TSC1 Data Collector

Using the Office Support Module II Charger To recharge the TSC1 battery using the Office Support Module II (OSM II) charger:

2.8.3

1.

Connect the TSC1 to the OSM II using the TSC1 to 5-pin Lemo cable (part number 32959). Connect this cable to the TSC1 and the 5-pin Lemo cable that comes out of the OSM II.

2.

Plug the OSM II into the main power.

Using the Battery Charger To recharge the TSC1 battery using the (optional) battery charger: 1.

Remove the Lithium-ion battery from the TSC1 data collector. To do this, turn off the TSC1, unscrew the battery cover screw (see Figure 2.3) and take out the battery. Note – No data is lost when you remove the TSC1 battery.

24

2.

Connect the output plug of the AC adaptor (part number 30413) to the input power port of the battery charger.

3.

Connect the AC power plug of the adaptor to an AC power source that provides 90–264 V of 50/60 Hz single-phase power.

Trimble Survey Controller Reference Manual Volume 1

Page 55

The TSC1 Data Collector

2

Figure 2.3 shows the location of the internal battery in a TSC1 data collector.

Battery Battery cover

Figure 2.3

Location of the TSC1 internal battery

Trimble Survey Controller Reference Manual Volume 1

25

Page 56

2

The TSC1 Data Collector

4.

Connect the battery charger as shown in Figure 2.4, and insert the batteries.

To main power

Battery Contact indicator Power indicator

Temperature indicator

Charge indicator

AC adaptor

Figure 2.4

TSC1 battery charger

When the battery charger is properly connected, the green Power indicator light comes on. When you insert a battery into the battery charger, the battery status indicators show the status of the battery in each slot. These indicators are described in the following section. Charge status An orange light labeled CONTACT and a green light labeled CHARGE are located next to each battery slot. They indicate the charge status of the battery in that slot. When you insert a battery into the charger, the orange Contact light next to the battery slot comes on and the green Charge indicator light starts flashing.

26

Trimble Survey Controller Reference Manual Volume 1