Page 41

CHAPTER

2 2

The TSC1 Data Collector In this chapter: ■

Introduction

■

Turning the TSC1 data collector on and off

■

Screen

■

Rebooting

■

Data capacity (memory)

■

Operating temperature and humidity ranges

■

Power sources

■

Recharging the TSC1 battery

■

Using the 9 V TSC1 battery adaptor

■

Ports

■

Maintenance

■

Upgrading the Trimble Survey Controller software

Page 42

2

The TSC1 Data Collector

2.1

Introduction The Trimble Survey Controller field computer consists of Trimble Survey Controller version 7.7 software running on the Trimble System Controller (TSC1™) data collector. This chapter introduces the hardware and describes how to use it. For information about how to use the Trimble Survey Controller software, see Chapter 3, General Operation. Figure 2.1 and Figure 2.2 show different views of the TSC1 data collector. They will help you to become familiar with the terms used in this manual.

12

Trimble Survey Controller Reference Manual Volume 1

Page 43

The TSC1 Data Collector

2

PC card

Function keys

Multi-directional arrow key

Backspace key

Second function key Caps lock key

Space key

On/Off key

Help key

To receiver Power/data cable Figure 2.1

Front view of the TSC1 data collector

Trimble Survey Controller Reference Manual Volume 1

13

Page 44

2

The TSC1 Data Collector

Top port PC card cover release button

Battery cover

Battery cover screw

Bottom port Power/data cable Figure 2.2

14

Back view of the TSC1 data collector

Trimble Survey Controller Reference Manual Volume 1

Page 45

The TSC1 Data Collector

2.2

2

Turning the TSC1 Data Collector On and Off To turn on the TSC1 data collector, make sure that power is supplied (see Power Sources, page 21). Then press the green on/off key marked .

|

To turn off the TSC1, hold down

B 2.3

| for one second.

Tip – For the location of this key and other keys on the TSC1 data collector keypad, see Figure 2.1.

Screen The TSC1 has an LCD screen. This screen responds to heat, and prolonged exposure to full sunlight can cause it to darken. If the screen does darken, turn it away from direct sunlight to get it to return to normal.

C 2.3.1

Warning – Repeated exposure to direct sunlight causes the screen to degrade.

Contrast To increase the screen contrast, press To decrease the screen contrast, press

[e [f

. .

The TSC1 can automatically set the screen contrast. See Hardware, page 55.

2.3.2

Backlight To toggle the screen backlight on and off, press

[l

.

Trimble Survey Controller Reference Manual Volume 1

15

Page 46

2

The TSC1 Data Collector

2.4

Rebooting If the Trimble Survey Controller software fails to respond to keystrokes, you might have to reboot the system. Turn off the TSC1 and turn it back on again.

|

If this does not work, hold down the key for five seconds, then release it. Press it again to turn on the Trimble Survey Controller software. If this does not work, perform a warm boot. Note – If the software fails to respond to keystrokes, first check that the TSC1 data collector is receiving power.

2.4.1

Warm Boot A warm boot shuts down the hardware and restarts the Trimble Survey Controller software. Note – You do not lose data when you perform a warm boot. To perform a warm boot:

|

1.

Turn off the TSC1 data collector. It may be necessary to hold for five seconds. down

2.

Hold down the TSC1.

3.

. The TSC1 data When you hear three beeps, release collector restarts and, a few seconds later, runs the Trimble Survey Controller software.

B while you press and release

B

|

. This turns on

Note – A warm boot restores the Trimble default settings. If the warm boot fails, perform a cold boot.

16

Trimble Survey Controller Reference Manual Volume 1

Page 47

The TSC1 Data Collector 2.4.2

2

Cold Boot A cold boot erases the internal memory and restarts the Trimble Survey Controller software. It does not affect data stored on the PC card.

C

Warning – A cold boot causes you to lose all data in the internal memory. Only perform one if a warm boot fails.

To perform a cold boot:

|

1.

Turn off the TSC1 data collector. It may be necessary to hold for five seconds. down

2.

and together while you press and release Hold down . This turns on the TSC1. After a few seconds a message appears:

|

[ %

[ %

Force Reformat Internal Media Please Wait......

3.

2.5

Release and . After a few minutes, the Trimble Survey Controller software starts.

Data Capacity (Memory) The TSC1 data collector is supplied with 2 MB of internal memory for data storage. Although the TSC1 can hold a large volume of data, Trimble recommends that you transfer data files to an office computer daily. Note – If you are in a survey and the main memory of the TSC1 data collector is nearly full, the Trimble Survey Controller software ends the survey. To create more memory space, download the data and purge some files. While some data collectors use battery-backed static memory, the TSC1 uses flash memory. With flash memory, there is no need for a backup battery to preserve data when the system is turned off. This means that the TSC1 data collector provides exceptionally secure data storage. Trimble Survey Controller Reference Manual Volume 1

17

Page 48

2

The TSC1 Data Collector

To increase the memory available for data storage, insert a PC card into the side of the TSC1. PC cards supplement the internal flash memory and are available in various sizes (for example, 4 MB, 10 MB, and up to 85 MB). For more information see Chapter 8, PC Cards.

2.5.1

Real-Time Surveys Table 2.1 shows the maximum amount of free space that is available for data storage during a real-time survey, as well as the estimated number of positions that can be stored. It shows values for standard RTK positions with QC1 records, and for RTK positions with QC1 and QC2 / QC3 records. For more information, see Quality Control Records, page 379. Table 2.1

2.5.2

Position storage capacity

Memory

Available memory

RTK + QC1 Number of positions

RTK + QC1 + QC2 / QC3 Number of positions

2 MB

1.795 MB

5,800

4,600

Postprocessed Surveys Postprocessed surveys continuously log raw GPS observation data. The number of points that can be stored in the TSC1 data collector depends on the logging/epoch rate and the number of satellites tracked.

18