Page 57
The TSC1 Data Collector
2
Only one Charge indicator light flashes, even if you insert two batteries; the other one stays off. This indicates that the charger is charging one battery while the other battery is in standby mode. The second green indicator only lights up when the first battery is fully charged. When a battery is fully charged, the Charge indicator light changes from flashing to continuous. The Charge light for the next battery slot then starts to flash, indicating that the battery has started to charge. When the Charge indicator stays on continuously, remove the fullycharged battery from the slot and insert another battery that requires charging. Table 2.4 summarizes the Contact indicator light displays. Table 2.4
Contact indicator
Orange light status
Meaning
Off
No battery is in the slot, or the terminal contact is poor
On
A battery is in the slot
Table 2.5 summarizes the Charge indicator light displays. Table 2.5
Charge indicator
Green light status
Meaning
Off and the orange Contact indicator is on
Charging is required but has not yet started
Flashing on and off
Charging is in progress
On continuously
The battery is fully charged
If you leave both batteries fully charged in the slots, the charger automatically checks the condition of each battery periodically. If either battery requires more charge, the corresponding green light starts to flash again as that battery is charged. The other slot still displays a continuous green light.
Trimble Survey Controller Reference Manual Volume 1
27
Page 58
2
The TSC1 Data Collector
Other indicators The battery charger has a temperature warning indicator (labeled TEMP) next to the Power indicator. The Lithium-ion battery must be charged in an environment where the temperature is between 0o and +50oC. If the charger is operated at a temperature outside of this range, the green Charge indicators go off and a red temperature warning light comes on. This indicates that the charger has stopped charging and is in sleep mode, where it takes minimal power from the AC power source. When the environment returns to the required temperature range, the charger begins charging automatically and the red temperature warning light turns off. AC adaptor The AC adaptor (part number 30413) supplied with the battery charger can deliver a maximum output of +18 V DC at 1.66 A. It has built-in overload and short circuit protections. The AC adaptor provides enough output to drive one dual battery charger (part number 33282-00) and one TSC1 data collector simultaneously. When the batteries are fully charged (or when there are no batteries in the slots), the charger uses very little power from the AC source. Because the charger is so efficient, you can leave it on at all times.
2.8.4
Using a Low Voltage Power Supply To recharge the TSC1 battery using a power source of less than 15 V:
28
1.
Connect the TSC1 data collector to a receiver with an external power source, or directly to a camcorder battery.
2.
Make sure that the TSC1 cannot turn itself off while the battery is being charged:
?
a.
Select Configuration / Controller / Time/date.
b.
Access the Timeout field and press
Trimble Survey Controller Reference Manual Volume 1
.
Page 59
The TSC1 Data Collector
3.
2
Select Configuration / Controller / Hardware and set the Low voltage charging enabled field to Yes. This field defaults back to No when the TSC1 is turned off. A charge icon appears in the status line until the battery is fully charged. See Table 3.3 on page 42. Note – Do not start a survey while charging the battery of the TSC1 data collector in this way.
Trimble Survey Controller Reference Manual Volume 1
29
Page 60
2
The TSC1 Data Collector
2.9
Using the 9 V TSC1 Battery Adaptor The TSC1 is usually powered by a rechargeable Lithium-ion battery that is supplied with the unit. However, a 9 V battery adaptor is available if you want to use a 9 V battery to power the unit. Insert a 9 V battery into the adaptor, and insert the adaptor into the TSC1 as shown in Figure 2.5.
Battery adaptor
9 V battery
Figure 2.5
30
9 V battery adaptor inserted into the TSC1
Trimble Survey Controller Reference Manual Volume 1
Page 61
The TSC1 Data Collector
2.10
2
Ports The TSC1 data collector has two data/power ports. One port is at the bottom of the unit, the other is at the top on the back. Both ports function in the same way. Figure 2.2 shows where these ports are located on the TSC1. The Trimble Survey Controller software automatically detects which port is connected to an external device. Each port takes a 7 pin 0-shell Lemo plug. Figure 2.6 shows the position of the sockets.
1 2 3
Figure 2.6
6 5
7 4
Pinout diagram of the TSC1 port
Table 2.6 describes the function of each socket. Table 2.6
Pinout functions – TSC1 data collector ports
Socket number
Top port function
Bottom port function
1
Signal ground
Signal ground
2
Power 1 in return (–)
Power 2 in return (–)
3
Transmit data (TXD1)
Transmit data (TXD2)
4
Request to send (RTS1)
Request to send (RTS2)
5
Clear to send (CTS1)
Clear to send (CTS2)
6
Power 1 in (+)
Power 2 in (+)
7
Receive data (RXD1)
Receive data (RXD2)
Trimble Survey Controller Reference Manual Volume 1
31
Page 62
2
The TSC1 Data Collector
2.11
Maintenance The TSC1 data collector does not need to be serviced. To clean it, use a soft cloth moistened with water and a mild soap. If the TSC1 develops a fault, transfer any data to an office computer and reset the TSC1 with a cold boot as described on page 17. If you cannot transfer the data, do not perform a cold boot. Contact your local dealer for advice. Contact your local Trimble dealer for repairs, replacement parts, service information, and technical assistance.
2.12
Upgrading the Trimble Survey Controller Software Use the WinFLASH™ software to upgrade the software and/or options on the TSC1 data collector. WinFLASH comes with full instructions on how to carry out the upgrade. First download all files that you want to keep, then connect the equipment as described in Connecting the TSC1 Data Collector, page 160. Run WinFLASH on the office computer and follow the instructions on the screen.
Ó
Note – Depending on the number of Survey Styles you have defined, you may need to use the softkey. If WinFLASH does not connect to the TSC1 data collector, use the TSC1 to select Configuration / Controller / Hardware. Press . A message appears on the TSC1 screen:
Ó
Please confirm. Upgrade will delete all of your data and then reboot. Do you want to continue?
Press
32 y and run WinFLASH again.
Trimble Survey Controller Reference Manual Volume 1