Page 533

Using Conventional Instruments

19

î

If the residuals for an observation are high, it may be desirable to disable the observation from the round. To disable an observation component (HA, VA or SD), highlight it and press . When Use is set to No, the pairs of observations (Face 1 and Face 2) made to the point in the round are deleted. The mean observations, residuals and standard deviations are recalculated.

î O

The softkey is not available for backsight points. Observations to the backsight are used to orientate observations and cannot be deleted. To accept the changes and return to the Station details screen, press .

19.7

Staking Out The Stakeout menu provides options for staking out coordinates, lines, curves, slopes, roads, and surfaces. This section shows how to stake out a point using a conventional instrument. For information about staking out a road, see Chapter 18, Roading.

C

Warning – Do not stake out points and then change the coordinate system or perform a calibration. If you do, these points will not be in terms of the new coordinate system. They will also be inconsistent with points staked out after the change.

Trimble Survey Controller Reference Manual Volume 2

501

Page 534

19 19.7.1

Using Conventional Instruments

General Procedure To stake out a point, set up the conventional instrument and complete a station setup: 1.

Change the stakeout settings if necessary (see the next section).

2.

Define the point/line/curve/DTM. To do this, use one of the following methods:

3.

4.

– key in data

– upload a file from a PC

– calculate coordinates using one of the Cogo functions

From the main menu, select Survey. From the Survey menu, select Stakeout, then choose what you want to stake out (Points, Lines, Curves, Roads, or DTMs).

ã

Turn the conventional instrument to the angle indicated on the screen. If you are using a servo or robotic instrument, press or set the Stakeout auto turn field to Yes in the Survey Style to automatically turn the instrument to the angle indicated on the screen. If you are operating a robotic instrument remotely, the instrument will automatically track the prism as it moves (if lock is maintained). The stakeout graphical display will update accordingly.

m

The graphics indicate when the instrument is on line.

50 2

5.

. Adjust the Move the target so that it is on line and press target distance from the instrument as indicated by the graphics, and measure again.

6.

When the graphical display indicates that the target is on the . point, press

7.

Store the as-staked point (this step is optional).

8.

Repeat Steps 5 and 6 until all points are staked out.

9.

End the survey.

z

Trimble Survey Controller Reference Manual Volume 2

Page 535

Using Conventional Instruments

19

Note – The defined point/line/curve/road/surface must be stored in the Trimble Survey Controller software database before you can stake it out.

19.7.2

Stakeout Settings You can change the default values for as-staked points. You can also change how certain values are displayed during stakeout. To specify what distances are used and displayed by the Trimble Survey Controller software: 1.

From the main menu, select Configuration / Job / Cogo settings.

2.

Set the Distances field as required. To apply sea level correction, for example, set the Distances field to Sea level.

Stationing values can be displayed in the following formats: 1000.0, 10+00.00, or 1+000.0. To change the format: 1.

From the main menu, select Configuration / Job / Units.

2.

Set the Stationing field as required.

To change the stakeout settings for a Survey Style:

B

E

1.

From the main menu, select Configuration / Survey Style.

2.

Highlight your Conventional Survey Style and press

3.

Select Stakeout. For more information about the fields that can be edited, see Stake To Options, page 414.

st

.

Tip – For the next section, use the online Help if necessary. Press the key and then press and choose the stakeout topic.

Trimble Survey Controller Reference Manual Volume 2

?

503

Page 536

19

Using Conventional Instruments o

To change the stakeout settings for the current survey only: 1.

From the Survey/Stakeout screen press screen appears, as shown in Figure 19.25.

. The Options

Figure 19.25 Options screen – stakeout

2.

19.7.3

Set the fields as required. For more information, see Stakeout, page 459.

Using the Graphical Display During Stakeout When staking out a point, line, curve, or road, use either the text on the right of the screen or the graphical display on the left to navigate to the point. This section describes how to use the graphical display. The general rule in using the graphical stakeout is that a solid/filled arrow means action. Use these arrows to locate the point within a certain tolerance. You can configure the tolerances for both angles and distances in the Options screen. The stakeout graphical display operates in one of two modes: Distances, or Angle and distance. To choose a mode, set the Display/Deltas field in the Options screen. The next section shows examples of each mode.

50 4

Trimble Survey Controller Reference Manual Volume 2

Page 537

Using Conventional Instruments

19

To use the graphical display during stakeout: 1.

When you select a point to stake out, the stakeout graphical display screen appears. See Figure 19.26.

Figure 19.26 Initial screen of graphical display – stakeout

A large arrow indicates the direction in which the instrument must be turned. The screen also indicates the angle that the instrument must display.

ã or set If you are using a servo or robotic instrument, press Stakeout auto turn to Yes in the Survey Style, to turn the instrument automatically to the angle indicated on the screen. If you are operating a robotic instrument remotely from the target, the graphical display is reversed and the arrows are shown from the target (prism) to the instrument. 2.

When the instrument is within the angular tolerance, the graphical display shows two hollow/outline arrows. (Use the Options screen to set angular tolerance.)

Trimble Survey Controller Reference Manual Volume 2

505

Page 538

19 m

Using Conventional Instruments

3.

Press . When the distance measurement is made, a screen similar to one of those shown in Figure 19.27 appears.

Figure 19.27 Graphical display screen – distance measurement made

The left and right arrows are curved or straight depending on the mode set in the Options screen: –

In the left screen above, the Display/Deltas field is set to Angle and distance. The arrows are curved.

–

In the right screen, the Display/Deltas field is set to Distances. The arrows are straight.

The hollow left and right outline arrows show that the instrument is on line. The solid arrow indicates that the target must move away from the instrument.

50 6

Trimble Survey Controller Reference Manual Volume 2

Page 539

m

Using Conventional Instruments

4.

19

When the target has moved, press again. If the instrument is turned off line, the two outline arrows disappear and a solid one appears. Figure 19.28 shows two different ways to view this.

Figure 19.28 Graphical display screen – measurement made, instrument off line

–

In the left screen above, the Display/Deltas field is set to Angle and distance. The instrument must be turned to the left by the amount shown. When the instrument is on line again, the two outline arrows reappear. Direct the target on line. The down arrow indicates that the target must move towards the conventional instrument.

–

B

In the right screen, the Display/Deltas field is set to Distances. The target must move to the left. The instrument is then turned to follow the target. When the instrument is on line, the two outline arrows reappear.

Tip – If you are using a servo instrument press the instrument back on line.

ã [t , or to turn

Trimble Survey Controller Reference Manual Volume 2

507

Page 540

19

Using Conventional Instruments

5.

When the target has moved, press m again.

If the instrument is on line, two left/right outline arrows appear. If the distance is not yet correct, a solid up/down arrow shows the direction and amount that the target must move towards or away from the instrument. See Figure 19.27. 6.

m again. If the measurement to the target is within the Press angular and distance tolerances set in the Options screen, four hollow/outline arrows appear and the center point is filled in. See Figure 19.29.

Figure 19.29 Graphical display screen – point located within tolerance

If you are operating a robotic instrument remotely, the instrument automatically tracks the prism as it moves and continuously updates the graphical display. If a measurement to the target is within the angular and distance tolerances, press . 7.

m z s

Do one of the following: –

If you want to record the as-staked point:

s

If the View deltas before storage field is set to Yes, press . The measurement and the stakeout deltas are displayed. Press to store the point.

If the View deltas before storage field is set to No, press to store the point.

50 8

Trimble Survey Controller Reference Manual Volume 2

Page 541

–

19.7.4 y

Using Conventional Instruments

19

=

If you do not want to record the as-staked point, press then . You return to the list and can stake out more points.

Staking Out a Point To stake out a point: 1.

From the main menu, select Survey. From the Select Survey Style menu, select your Conventional Survey Style.

2.

Select Station Setup and perform a station setup.

3.

Select Stakeout / Points. The Stakeout/Points list appears.

4.

to transfer points in the Trimble Survey Controller Press software database to the Stakeout/Points list. The Select points screen appears, as shown in Figure 19.30.

A

Figure 19.30 Select points screen – selection methods

5.

From the list, choose the method by which points are to be selected.

Trimble Survey Controller Reference Manual Volume 2

509

Page 542

19

Using Conventional Instruments

If you choose Select from list, for example, a list of points in the Trimble Survey Controller software database appears. See Figure 19.31.

Figure 19.31 Select points screen – list of points

/

To select a point, from the list, highlight it and then press . A check mark appears beside the selected point name. Do this for each point that you want to add to the Stakeout list.

\ \ to return to the Stakeout/Points screen.

6.

Press

7.

Select the point to be staked out. (To do this, highlight the point .) and press The stakeout graphical display screen appears. It displays the angle to which you should turn the instrument and the distance from the instrument to the point, together with a graphical representation of this. See Figure 19.32.

Figure 19.32 Initial screen of graphical display – stakeout 51 0

Trimble Survey Controller Reference Manual Volume 2