Page 523
Using Conventional Instruments
19
If View before storage is set to No, the point is stored with a classification of Check. If it is set to Yes, the Check shot deltas appear on the screen. See Figure 19.18.
Figure 19.18 Survey/Check shot screen – check shot deltas
If you observe the point from the same station setup that you originally measured it from, the deltas are the difference in observation values between the original observation and the check observation. The deltas displayed are: horizontal angle, vertical distance, horizontal distance, and slope distance. If you observe the point from a different station setup from the one you originally measured it from, the deltas are in terms of the best coordinates from the original point to the check point. The deltas displayed are: azimuth, vertical distance, horizontal distance, and slope distance. 5.
Ð s to store the check point. Press Press measurement.
= to abandon the to display the Survey / Check backsight screen. This is Press similar to the Survey / Check point screen, but the Point name field shows the backsight of the current station setup. You cannot edit this field.
Ñ
To observe a check shot to the backsight, use the same procedure as described above. To return to the Survey / Check point screen, press
.
Trimble Survey Controller Reference Manual Volume 2
491
Page 524
19
19.6
Using Conventional Instruments
Measuring Rounds of Observations This section shows how to measure multiple sets (rounds) of observations with a conventional instrument and the Trimble Survey Controller software. A round consists of a set of both Face 1 and Face 2 observations. With rounds, you measure the first face observations. The Trimble Survey Controller software builds the rounds list then guides you through a specified number of rounds of observations by:
19.6.1
• directing you to change face when required
• defaulting to the correct point details for each observed station
• displaying the results and allowing you to delete bad data
Building the Rounds List The rounds list contains the points used in the rounds observations. The Trimble Survey Controller software automatically builds this list during the first round of observations made on the first face (typically Face 1). The backsight point observed during station setup, is added to the list first. The last point is added when the first round of observations is completed on the first face. When a point is added to the rounds list, the Trimble Survey Controller software takes note of the following details: •
Point name
•
Feature code
•
Target height
•
Prism constant
The Trimble Survey Controller software uses this information as the default values for all subsequent rounds observations. The rounds list cannot be edited, so observe all points that are to be included in the rounds observations during the first round on the first face. 49 2
Trimble Survey Controller Reference Manual Volume 2
Page 525
Using Conventional Instruments
19
To add a point to the rounds list: 1.
Complete a station setup. For more information, see Station Setup, page 468. The backsight point will be added to the rounds list first.
2.
From the Survey menu, select Measure rounds. The Survey/Measure rounds screen appears. See Figure 19.19.
Figure 19.19 Survey/Measure rounds screen
The Survey/Measure rounds screen shows what face the instrument is on, and the number of the current round (shown in brackets). For example, Figure 19.19 indicates the instrument that is on Face 1 of the first round. 3.
To change the settings for the current survey, press Options screen appears as shown in Figure 19.20.
o
. The
Figure 19.20 Options screen–rounds Trimble Survey Controller Reference Manual Volume 2
493
Page 526
19
Using Conventional Instruments
Use the Options screen to specify the prism constant of the target for each observation in the rounds list. Enter a negative value if the prism constant is to be subtracted from measured distances. 4.
To add a point to the rounds list, follow the same procedure for measuring a topo point. For more information, see Measuring a Topo Point, page 483. If the View before storage field in the Survey Style is set to Yes, the measurement information is displayed. See Figure 19.21.
Figure 19.21 Survey/Measure rounds screen–measurement
If the View before storage field is set to No, the point is stored automatically, and the point name increments (based on the Auto point step size setting). 5.
When the rounds list is complete, press
é
.
The message First face completed appears and the Trimble Survey Controller software prompts you for the next point to be measured in the rounds of observations.
= in the Survey/Measure rounds screen, the Note – If you press current rounds list is lost. A new station setup is required to start another round.
49 4
Trimble Survey Controller Reference Manual Volume 2
Page 527
Using Conventional Instruments 19.6.2
19
Measuring a Point in a Round of Observations When the rounds list has been built, the Survey/Measure rounds screen displays the default target details for the next point to be observed. If the TSC1 data collector is connected to a servo or robotic instrument and the Stakeout auto turn field is set to Yes in the Survey Style, the Trimble Survey Controller software automatically turns the instrument to the calculated horizontal and vertical angle.
C
Warning – When using servo or robotic instruments, check that the instrument has sighted the target accurately, and manually adjust it if required. Some instruments can perform accurate sighting automatically. For information on the instrument specifications, refer to the instrument manufacturer’s documentation.
Making a measurement Once the rounds list has been built, the Trimble Survey Controller software automatically displays the last used target information for the next point to be measured.
m
To measure a point: 1.
Press
.
When the observation is stored, the Trimble Survey Controller software defaults the point name and the target information for the next point in the rounds. Note – If you observe a point on the wrong face, the Trimble Survey Controller software will warn you after you try to store the point. 2.
Repeat this procedure until all observations are completed on the face.
When all observations have been completed, the Trimble Survey Controller software will display the results for the round. For more information, see Viewing the Results, page 498.
Trimble Survey Controller Reference Manual Volume 2
495
Page 528
19
Using Conventional Instruments
If you cannot complete the observations, press warning message appears.
y
é
. The following
Please confirm: Not all points have been observed. End observations on this face?
Press to confirm that you want to end observations on this face and begin observing the next set of rounds. If the Measure distance on face 2 field is set to No, the measurement method for observations on Face 2 will always use Angles only by default.
ãã
If the TSC1 data collector is connected to a servo or robotic softkey is also available. After a point is stored, instrument, the press to automatically turn the instrument to the next target. If the Stakeout auto turn field in the Survey Style is set to Yes, the instrument will automatically turn.
19.6.3
Duplicate Point Actions (Rounds) The Trimble Survey Controller software treats points in rounds observations according to the Survey Style settings in the Duplicate point actions screen. For more information, see Duplicate point actions, page 461. If you use the default settings in the Duplicate points action screen, the Duplicate point: Out of tolerance screen appears every time a point of the same name is observed. If you change the settings, the Duplicate point: Out of tolerance screen appears only when the tolerance values have been exceeded. For larger scale surveys, you may need to increase the Duplicate point tolerance settings for the Survey Style. Set the tolerances at an appropriate value to check for gross errors, and examine the observation residuals for better quality control. For information on viewing the observation residuals, see Viewing the Results, page 498.
49 6
Trimble Survey Controller Reference Manual Volume 2
Page 529
Using Conventional Instruments
19
When a new point is further from the point observed in the previous round than the tolerance specified in the Survey Style settings, the Duplicate point: Out of tolerance screen appears. Set the Action field to one of the following options: •
Discard–discard the point without storing
•
Store another–store the point
Duplicate Backsight Point When the orientation is changed between consecutive rounds, that is the backsight point is re-observed in the new round, the Duplicate backsight point screen appears. The options are: •
Discard–discard the observation without storing
•
Store and reorient–store another observation that provides a new orientation for subsequent points measured in the current round. Previous observations are not changed.
F1/F2 Observation Tolerance If the Face 1 and Face 2 observations are out of tolerance, the Observation: Out of tolerance screen appears. The options are: •
Discard–discard the observation without storing
•
Store another–store the observation, the matched pair and the mean turned angle o
Note – To change the F1/F2 Observation tolerance setting during the from the Survey/Measure rounds screen. survey, press
19.6.4
ê
Skipping Observations During rounds observations, you can skip an observation by pressing if the current point cannot be measured. The Trimble Survey Controller software will then default to the next point in the rounds list.
Trimble Survey Controller Reference Manual Volume 2
497
Page 530
19
Using Conventional Instruments
It is not possible to skip observations: • when building the rounds list
• if the observations are made to the first point (backsight) in the rounds list
When the Trimble Survey Controller software has reached the end of the rounds list and points have been skipped, the warning message Observe skipped points? appears.
y n to observe the points that were skipped during that round. Press The observations can be skipped again if required. Select to end the round. Points that are skipped on the first face are automatically skipped on the second face. Similarly, if a point is skipped on the second face, the first face observation will be disregarded. If a point is skipped in one round, all subsequent rounds continue to prompt for observations to that point.
19.6.5
Viewing the Results At the end of each round, the Trimble Survey Controller software displays the Rounds summary screen, as shown in Figure 19.22.
Figure 19.22 Rounds summary screen
Use the Rounds summary screen to: • 49 8 continue and observe more rounds
Trimble Survey Controller Reference Manual Volume 2
Page 531
Using Conventional Instruments
• view specific point/observation details
• end the current rounds session
19
The Rounds summary screen shows details of the rounds that have been completed. The maximum residuals are displayed for quick reference. Note – In two-dimensional surveys where the instrument or target heights are null, the observed vertical angle and slope distance residuals and standard deviation are displayed as N/A. Do one of the following:
J e W
•
To return to the Survey/Measure rounds screen and observe . another round, press
•
To end the current rounds session, press
To view details of the observations, press screen appears, as shown in Figure 19.23.
Figure 19.23 Screen showing station details
To return to the Rounds summary screen, press
.
. The Station details
=
.
Station details screen Results Use the Station details screen to: • view the observation details from the current station in the round.
Trimble Survey Controller Reference Manual Volume 2
499
Page 532
19
Using Conventional Instruments
• view individual point residuals and remove bad observations from a round.
The Station detail screen shows the mean (turned) horizontal angle and standard deviation for all points observed from the station. To change the observation display view, do one of the following: •
Press
•
Press
ì í
ë to display the mean vertical angle.
to display the mean slope distance.
D
To return to the mean horizontal angle view, press
.
To view individual point residuals for each round and remove bad . The Point details observations, highlight the point and press screen appears, as shown in Figure 19.24.
Figure 19.24 Screen showing point details
Point details screen The Point details screen shows the residuals of the observed point for each round. The Use column shows the observations in use (displayed as Yes), and those that have been removed (displayed as No). If observations have been skipped in a round, N/A is displayed. Use the views.
50 0
ëì í , or softkeys to change the residual display
Trimble Survey Controller Reference Manual Volume 2