Page 493

Using Conventional Instruments

4.

19

If you define a DTM and set the Display cut/fill to DTM field to Yes, the TSC1 displays cut or fill relative to that DTM. Use the DTM field to specify the name of the DTM to be used.

Duplicate point actions In a conventional survey, you can set the tolerances for a duplicate point warning. You specify the maximum distance that the new point can be from the existing point. A duplicate point warning appears when you try to store a new point, but only if the duplicate point is outside the tolerance you set. For more information, see Duplicate Point Actions, page 140. Note – In a conventional survey, when you enter a point name that already exists, the message Point already exists does not appear. This is because you may want to regularly measure points on both faces. When you use a conventional instrument to measure points on two faces, the Trimble Survey Controller software behaves according to the settings in the Duplicate point actions screen. For example: If you make a Face 1 observation to a point and then store a Face 2 observation to the same point (with the same point name), the Trimble Survey Controller software performs a duplicate observation tolerance check between the two observations, based on the F1/F2 observation tolerance settings: •

If the Face 1 and Face 2 observations are within tolerance, they are averaged. A matched pair record is stored immediately after the Face 2 observation. Furthermore, a mean turned angle record is stored after the matched pair. For more information about matched pairs and mean turned angles see, Measuring a Point in Two Faces, page 487.

•

If the Face 1 and Face 2 observations are out of tolerance, the Observation: Out of tolerance screen appears. The options are: –

Discard – discard the observation without storing

–

Rename – rename to a different point name Trimble Survey Controller Reference Manual Volume 2

461

Page 494

19

Using Conventional Instruments

–

Store as check – store with a classification of Check

–

Store another – store the observation and the matched pair

–

Store and reorient – (this option only appears if you are observing a backsight point) store another observation that will provide a new orientation for subsequent points measured in the current station setup. Previous observations are not changed. Use this if you are doing multiple rounds of observations.

Note – If the target height changed between the Face 1 and Face 2 observations, the Trimble Survey Controller software reduces the Face 1 and Face 2 observations to HA HD VD, and produces a matched pair that is the mean HA HD VD. When you make the next observation to the same point, the Trimble Survey Controller software performs a duplicate point tolerance check using the best point in the database and the point just measured: •

If it is within tolerance, the new observation is stored

•

If it is out of tolerance, the Duplicate point : Out of tolerance screen appears. For more information, see Duplicate point : Out of tolerance screen, page 140.

46 2

Trimble Survey Controller Reference Manual Volume 2

Page 495

Using Conventional Instruments

19

Traverse options Use these options to specify how a traverse calculation is adjusted. Table 19.3 shows the options and what they do: Table 19.3 Field

Adjustment method

Traverse adjustment options Option

What it does

Compass

Adjusts the traverse by distributing the errors in proportion to the distance between traverse points

Transit

Adjusts the traverse by distributing the errors in proportion to the northing and easting ordinates of the traverse points

Error distribution Proportional to distance

Distributes the angular error among the angles in the traverse based on the sum of the inverses of the distances between traverse points

Equal proportions

Distributes the angular error evenly among the angles in the traverse

None

Does not distribute the angular error

Proportional to distance

Distributes the elevation error in proportion to the distance between traverse points

Equal proportions

Distributes the elevation error evenly among the traverse points

None

Does not distribute the elevation error

Angular

Elevation

Note – The Compass option is the same as the Bowditch method of adjustment. For information about calculating and adjusting a traverse, see Traverse, page 571.

Trimble Survey Controller Reference Manual Volume 2

463

Page 496

19

19.3

Using Conventional Instruments

Connecting to a Conventional Instrument This section shows how to assemble the equipment to do a survey with a conventional instrument.

19.3.1

Using a Trimble Conventional Instrument To assemble the equipment see Figure 19.2, then do the following:

C

46 4

1.

Set up the conventional instrument on a tripod.

2.

Connect the TSC1 data collector to the instrument using the 0-shell Lemo to 0-shell Lemo cable that is supplied with the instrument.

Warning – Do not force plugs into the ports. Align the red dot on the plug with the red line on the socket and then insert the plug carefully.

3.

Turn on the conventional instrument.

4.

Turn on the TSC1 and go to Station Setup, page 468.

Trimble Survey Controller Reference Manual Volume 2

Page 497

Using Conventional Instruments

19

Figure 19.2 shows the TSC1 data collector connected to Trimble’s conventional instrument.

F1

F2 F4

Figure 19.2

F3

F4

7 4 1 0

8 5 2 .

9 6 3 +/-

TSC1 data collector connected to a Trimble conventional instrument

Trimble Survey Controller Reference Manual Volume 2

465

Page 498

19 19.3.2

Using Conventional Instruments

Using a Third-Party Conventional Instrument To assemble the equipment, see Figure 19.3, then:

C

Warning – Before connecting the TSC1 data collector to a Leica (using GSI) or Geodimeter instrument, select the appropriate Survey Style. This Survey Style must specify the correct type of instrument. Otherwise, the Trimble Survey Controller will not connect to the instrument and the instrument will have to be reset.

1.

Turn on the TSC1 data collector.

2.

From the main menu, select Survey.

3.

Select the appropriate Survey Style.

4.

Connect the TSC1 data collector to the instrument. Attach the 0-shell Lemo to DB9 (male) cable (part number 37779) to one of the following: – the computer download cable for the instrument

– a cable provided by your local distributor

5.

Turn on the conventional instrument.

6.

Perform a Station Setup, page 468.

If you are using a robotic instrument: If you are operating a robotic instrument remotely, make sure the TSC1 data collector is connected to the remote end (target) and that the instrument is configured for remote operation.

46 6

Trimble Survey Controller Reference Manual Volume 2

Page 499

Using Conventional Instruments

19

Figure 19.3 shows the standard connection to a conventional instrument.

To conventional instrument

Figure 19.3

Standard connection to a third-party conventional instrument

Before starting a survey, make sure the instrument settings are compatible with the Trimble Survey Controller software. Find the settings for each model of instrument in Appendix E, Conventional Instrument Settings. Alternatively, contact your local Trimble dealer.

19.3.3

Auto-Connecting to a Conventional Instrument When you turn on the TSC1 data collector, the Trimble Survey Controller software tries to auto-connect to any device that it could be connected to. It first tries to connect to the device specified in the last Survey Style used. If this fails, it uses the information contained in all available Survey Styles to determine what instrument is connected to the TSC1.

Trimble Survey Controller Reference Manual Volume 2

467

Page 500

19

Using Conventional Instruments

Working through the list, the Trimble Survey Controller software checks the top and bottom ports of the TSC1 data collector for each instrument specified in the Styles. The more Survey Styles there are stored, the longer the auto-connect process takes.

B

Tip – To speed up the process, select a Survey Style.

If many Survey Styles are defined, the auto-connect process may take a long time. However, the Trimble Survey Controller software will connect to the device specified in the Survey Style when a survey is started. When the Trimble Survey Controller software is connected to an instrument, the conventional instrument icon appears. Note – If you turn on the TSC1 data collector and it is plugged into a Trimble conventional instrument, the Trimble Survey Controller software automatically turns on the instrument.

19.4

Station Setup Before starting work in the field, make sure that the conventional instrument is correctly configured in the Survey Style that you intend to use, and that the correct job is open. If you intend to combine GPS observations and conventional measurements in the same job, make sure that you define an appropriate coordinate system for the job. For more information, see Choosing a Coordinate System for a Conventional Survey, page 85. Then set up the instrument on a tripod over a point and connect it to the TSC1 data collector as shown in Connecting to a Conventional Instrument, page 464. Before measuring points, rounds of observations, or staking out, perform a station setup on the TSC1 data collector.

46 8

Trimble Survey Controller Reference Manual Volume 2

Page 501

Using Conventional Instruments

To perform a station setup:

19

\

1.

From the main menu, select Survey. Choose the required Survey . Style from the list and press

2.

Select Station setup.

For some instruments the Trimble Survey Controller software automatically checks to see if various corrections (PPM, prism constant, and curvature and refraction) are being applied correctly. When you select Station setup, messages are displayed in the status line showing what has/has not been checked. If the Trimble Survey Controller software finds that the corrections are being applied twice, a warning message appears. 3.

Follow the instructions in one of the following sections, depending on the information available. This could be: – known coordinates for both the instrument point and the backsight point

– known coordinates for the instrument point, unknown coordinates for the backsight point

– unknown instrument point coordinates, several known points surrounding the instrument point (resection)

– unknown instrument point coordinates (to be provided later), no known points to use as a backsight

Note – If you are using a coordinate system and zone from the Trimble Survey Controller software library, make sure that you use valid coordinates for that zone.

Trimble Survey Controller Reference Manual Volume 2

469

Page 502

19 19.4.1

Using Conventional Instruments

Known Coordinates for Both the Instrument Point and the Backsight Point If the instrument point and the backsight point are already stored in the Trimble Survey Controller software database: 1.

In the Instrument point name field, enter the station point name.

2.

Enter a value in the Instrument height field. Note – For a two-dimensional or planimetric survey, leave the Instrument height field set to null (?). No elevations are calculated. A Default elevation must be defined before the Trimble Survey Controller can coordinate 2D observations.

3.

Enter a value in the Backsight point name field. The Trimble Survey Controller software calculates the azimuth and inserts it in the Azimuth field, changing the field name to Azimuth (Computed).

4.

In the Backsight height field, enter the height of the backsight target.

5.

Choose an option in the Method field. The options are:

6.

47 0

–

Angles only – measures horizontal and vertical angles

–

Angles and distance – measures horizontal and vertical angles and slope distance

Sight the center of the backsight target and press

Trimble Survey Controller Reference Manual Volume 2 m

.