The text of a manual · part 57 of 83
Trimble Survey Controller Reference Manual: Using Conventional Instruments, pages 503 to 512
Pages 503 to 512 of 744, from Trimble Survey Controller Reference Manual
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Trimble TSC1
Page 503
Using Conventional Instruments
19
The horizontal and vertical distance deltas are displayed on the screen. These are the differences between the calculated position and the observed position of the backsight. See Figure 19.4.
)
Figure 19.4 s
Survey/Station setup screen – known coordinates
[)
Press repeatedly to view the measurement information. Alternatively, press to page down. 7.
Press to accept the station setup.
Station setup is complete.
19.4.2
Known Coordinates for the Instrument Point, Unknown Coordinates for the Backsight Point If the instrument point is already stored in the Trimble Survey Controller software database and the backsight coordinates are unknown: 1.
In the Instrument point name field, enter the station point name.
2.
Enter a value in the Instrument height field. Note – For a two-dimensional or planimetric survey, leave the Instrument height field set to null (?). No elevations are calculated.
Trimble Survey Controller Reference Manual Volume 2
471
Page 504
19
Using Conventional Instruments
3.
4. 5.
Enter a value in the Backsight point name field. Because the backsight point is not in the database, the Trimble Survey Controller software asks if you want to key in the point. Press .
n
In the Backsight height field, enter the height of the backsight target. In the Azimuth field, key in the azimuth (bearing) from the instrument point to the backsight point. The Trimble Survey Controller software uses this azimuth to calculate a coordinate for the backsight point. The Azimuth field name changes to Azimuth (Keyed in).
Note – If you do not know the azimuth at this stage, you can edit the azimuth record later in Review, or you can measure the backsight point using GPS. The coordinates of any points measured from that station will then be computed. 6.
Choose an option in the Method field. The options are: –
Angles only – measures horizontal and vertical angles With this method, no coordinates are calculated for the backsight point. (No coordinates can be obtained if there is no distance.)
– 7.
47 2 m
Angles and distance – measures horizontal and vertical angles and slope distance
Sight the center of the backsight target and press
Trimble Survey Controller Reference Manual Volume 2
.
Page 505
Using Conventional Instruments
19
The measurement information is displayed on the screen. No deltas are displayed because there are no known coordinates for the backsight. See Figure 19.5.
8.
s
Figure 19.5
Survey/Station setup screen – known instrument, unknown backsight
Press to accept the station setup.
Station setup is complete.
19.4.3
Unknown Instrument Point Coordinates, Several Known Points Surrounding the Instrument Point (Resection) Use a resection calculation to compute coordinates for the instrument point by making observations to known points during the station setup process. Note – In a resection, only use points that can be viewed as grid coordinates. (The resection calculation is a grid calculation.) A resection needs a minimum of: • three sets of angles
• two observations with horizontal and vertical angles and slope distances
Trimble Survey Controller Reference Manual Volume 2
473
Page 506
19
Using Conventional Instruments
The Trimble Survey Controller software uses a least-squares algorithm to compute the resection. This uses all of the data collected, which results in a statistically better result. For more information, see Resection Calculation, page 207. When doing a resection, make sure that the geometry of the observations will produce a stable result. In a two-point resection, the result can be unreliable if the angle between the instrument point and the two resection points is close to 180°. In a three-point resection, the result can be unreliable if the three points and the instrument point lie on a circle. For all resections, results are unreliable if the points you are observing to are close together. Table 19.4 shows the different types of resection provided by the Trimble Survey Controller software. Table 19.4
Values computed by resection
Known coordinate values for instrument point
Values computed by resection
Northing, Easting, Elevation
Northing, Easting, Elevation
Northing, Easting
Elevation
Elevation
Northing, Easting
None
Northing, Easting, Elevation
To do a resection: 1.
kr C
In the Instrument point name field, enter the station point name. The Trimble Survey Controller software warns that the point is , , and softkeys not in the database, and the appear.
47 4
Trimble Survey Controller Reference Manual Volume 2
Page 507
2.
r
19
Press . The Survey/Resection point screen appears, as shown in Figure 19.6.
Figure 19.6
3.
Using Conventional Instruments
Survey/Resection point screen
In the Instrument height field, do one of the following: –
For a two-dimensional resection, leave the field set to null (?).
–
For a three-dimensional resection, enter a value. If you entered a value in this field in the Station Setup screen, the Trimble Survey Controller software automatically transfers that value to this screen.
C
Warning – Once the resection is started you cannot enter a different instrument height.
The Calculate field indicates what values will be calculated by resection. For more information, see Table 19.4.
Trimble Survey Controller Reference Manual Volume 2
475
Page 508
19
O
Using Conventional Instruments
4.
Press . The Survey/Resection observation screen appears, as shown in Figure 19.7.
Figure 19.7
47 6
Survey/Resection observation screen
5.
In the Point name field, enter the name of the point you are observing to.
6.
In the Code field, enter a feature code (optional).
7.
Choose an option in the Method field. The options are: –
Angles only – measures the horizontal and vertical angles
–
Angles and distance – measures the horizontal and vertical angles and slope distance m
8.
In the Target height field, enter the height of the target you are observing.
9.
Sight the center of the target and press
Trimble Survey Controller Reference Manual Volume 2
.
Page 509
Using Conventional Instruments
19
The measurement information is displayed on the screen, as shown in Figure 19.8.
Figure 19.8 s
Survey/Resection observation screen – measurement information
= y
10. If the information is correct, press to accept the observation. To discard the measurement, press then
.
11. Repeat Steps 5 through 10 for all points that you are using in the resection calculation. When there is enough data for the Trimble Survey Controller software to calculate a resected position, the softkey appears.
cc to calculate the resection. The Resection results 12. Press screen appears, as shown in Figure 19.9.
Figure 19.9
Resection results screen
Trimble Survey Controller Reference Manual Volume 2
477
Page 510
19
Using Conventional Instruments
Resection results screen Use the Resection results screen to: • store the results of the resection
• add more observations
• view specific point/observation details
The Resection results screen shows the coordinates of the instrument point as calculated by the resection. It also shows the standard errors for the coordinates. For information about the formula used to calculate the standard errors, see Resection Calculation, page 207. Do one of the following:
AD s
•
To store the results of the resection immediately, press
•
To return to the Survey/Resection observation screen and . observe more points, press
.
. The Resection details To view details of the resection, press screen appears, as shown in Figure 19.10.
W s
Figure 19.10 Screen showing resection details
To return to the Resection results screen and store the resected point, press then .
47 8
Trimble Survey Controller Reference Manual Volume 2
Page 511
Using Conventional Instruments
19
Resection details screen Use the Resection details screen to: • view individual point residuals
• delete observations from the resection
• change which observations are used to compute a solution
A d
To return to the Survey/Resection observation screen and add more . points, press To delete an observation from the resection calculation, highlight it . and press
C
Warning – You cannot include an observation in a resection once the observation is deleted. To see what a solution would be like if you deleted a particular observation, access the Resection point screen. In the Use field (see Figure 19.11) change the setting to Off.
To return to the Resection results screen, press
W
.
\
To change which components (horizontal/vertical) of an observation . are used in the resection calculation, highlight the point and press The Resection point screen appears, as shown in Figure 19.11.
Figure 19.11 Resection point screen
Trimble Survey Controller Reference Manual Volume 2
479
Page 512
19
Using Conventional Instruments
Resection point screen The Resection point screen shows the residuals of the observed point. The Use field shows which components of the observation are used in the resection calculation. Table 19.5 shows the options in this field. Table 19.5
Use field options
Option
Description
H
Use only the horizontal values for that point in the calculation
V
Use only the vertical values for that point in the calculation
H,V
Use both the horizontal and vertical values for that point in the calculation
Off
Do not use the point in the calculation
Note – If you change the setting in the Use field, the resection recomputes when you accept the screen. To store the results of a resection, return to the Resection results screen.
19.4.4
Unknown Instrument Point Coordinates (to be Provided Later), No Known Points to Use as a Backsight If the coordinates of the instrument point (the station) are not known and will be provided later:
C
1.
Enter a value in the Instrument point name field. The Trimble Survey Controller software warns that the point is not in the and continue. Any coordinates measured database. Press from this point will have null (?) values.
2.
Enter a value in the Instrument height field. Note – For a two-dimensional or planimetric survey, leave the Instrument height field set to null (?). No elevations are calculated.
48 0
Trimble Survey Controller Reference Manual Volume 2