Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 55 of 83

Trimble Survey Controller Reference Manual: Using Conventional Instruments, pages 483 to 492

Pages 483 to 492 of 744, from Trimble Survey Controller Reference Manual

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Trimble TSC1

Page 483

CHAPTER

19 19

Using Conventional Instruments In this chapter: ■

Introduction

■

Configuring the Trimble Survey Controller software

■

Connecting to a conventional instrument

■

Station setup

■

Measuring points

■

Measuring rounds of observations

■

Staking out

■

Ending a conventional survey

Page 484

19

19.1

Using Conventional Instruments

Introduction This chapter describes how to use a conventional instrument with the Trimble Survey Controller software. It shows how to create a Conventional Survey Style, set up the equipment, and measure points. Other information about conventional instruments also occurs at relevant points elsewhere in this manual. The Trimble Survey Controller software interfaces with the following brands of conventional instruments: •

Trimble

•

Leica

•

Geotronics (Spectra Precision)

•

Sokkia

•

Nikon

•

Topcon

•

Zeiss

•

Pentax

Note – Contact your local Trimble dealer for a current list of the instruments that the Trimble Survey Controller software supports.

19.2

Configuring the Trimble Survey Controller software Use a Survey Style to change the configuration of the Trimble Survey Controller software quickly and easily for different types of survey. Each Survey Style contains a set of information specific to your equipment and preferences. The information is stored as a pattern or template that you can call up and re-use when necessary. To survey using the Trimble Survey Controller software and a conventional instrument, select a Conventional Survey Style.

45 2

Trimble Survey Controller Reference Manual Volume 2

Page 485

Using Conventional Instruments 19.2.1

19

Conventional Survey Styles A Conventional Survey Style defines the parameters for measuring and storing points. The Trimble Survey Controller software provides a default Survey Style for use with a conventional instrument - Trimble Conventional. It is suitable for use with Trimble’s conventional instrument. To use any other type of instrument, create a new Conventional Survey Style.

19.2.2

Creating a Conventional Survey Style To create a Conventional Survey Style:

w

1.

From the main menu, choose Survey. The Select Survey Style screen appears.

2.

Press

3.

Enter a name in the Style name field.

4.

Set the Style type field to Conventional.

5.

If a PC card is inserted, set the File location field as required.

6.

Press

\

.

to accept the screen.

A screen with options relevant to the chosen Style type appears, as shown in Figure 19.1.

Figure 19.1

Options screen – conventional survey style

Trimble Survey Controller Reference Manual Volume 2

453

Page 486

19

Using Conventional Instruments

7.

B

Select each item in turn and, in the screen that appears, set the fields to specify your equipment and preferences. For information about each menu item, see the following sections.

Tip – Alternatively, create a new Survey Style by copying and editing the Style called Trimble Conventional. For more information, see Copying and Editing a Survey Style, page 142.

Instrument Select Instrument to specify the type of instrument used and its communication parameters. The Trimble Survey Controller software interfaces with different brands of conventional instrument. Access the Manufacturer and Model (optional) fields to display a list of these names, and select the instrument you are using. Its default communications parameters appear. Change them if necessary. There is also a manual entry mode that lets you enter observations by keying them in. Use the Baud rate field to configure the Trimble Survey Controller software baud rate to match that of the conventional instrument. Use the Parity field to configure the Trimble Survey Controller software parity to match that of the conventional instrument. When you change the instrument type, the baud rate and parity settings automatically change to the default settings for the selected instrument. For more information on configuring a conventional Survey Style and your conventional instrument, see Appendix E Conventional Instrument Settings. Use the HA VA status rate field to set how often the Trimble Survey Controller software updates the horizontal and vertical angle display in the status line with information from the conventional instrument. Note – Some instruments beep when communicating with the Trimble Survey Controller software. You can turn off the beep in the instrument or set the HA VA status rate to Never.

45 4

Trimble Survey Controller Reference Manual Volume 2

Page 487

Using Conventional Instruments

19

The EDM precision field appears if the instrument type specified has more than one measuring mode that can be set by the Trimble Survey Controller software. Use it to specify how the EDM measures distances. The options vary depending on the setting in the Type field. For example, if you are using a Trimble conventional instrument, the options are 5 mm, 10 mm, 20 mm, and Instrument default. Select the Instrument default option to always use the setting on the instrument. Note – When you are using a Leica instrument in reflectorless mode, set the EDM precision to Instrument default. The Set backsight field appears if you can set the horizontal circle reading on the instrument when the backsight is observed. The options are No, Zero, and Azimuth. If you select the Azimuth option, when you observe the backsight the horizontal circle reading is set to the computed azimuth between the instrument point and the backsight point. When the instrument type is a servo or robotic instrument, the Stakeout auto turn field appears. Set this field to Yes if you want the Trimble Survey Controller software to operate the servos automatically during stakeout, when you are measuring a known (coordinated) point. When the instrument type is a servo or robotic instrument, the Servo options field also appears. Use it to specify which servos are used - choose from HA only, or HA & VA. The Stakeout turn to zero field appears when the instrument type is SET (Extended). Set this to Yes if you want the horizontal angle on the instrument to display 0° 00' 00'' when the instrument is turned on line with the point in stakeout. Use the Instrument precision fields to record the precisions of the instrument. Do one of the following: •

Leave them as null.

•

Enter the manufacturer’s values.

•

Enter your own values based on your observing techniques.

Trimble Survey Controller Reference Manual Volume 2

455

Page 488

19

Using Conventional Instruments

If you enter values, they are used by the Trimble Geomatics Office software to compute the standard error statistics for an observation. If you leave the fields as null, the Trimble Geomatics Office software default values are used to compute the standard error statistics. Target Select Target to enter information about the target in use. Use the Prism constant field to specify a prism constant (the distance offset specific to each prism). When the prism constant is to be subtracted from measured distances, make sure that you enter a negative value. For more information about how the correction is applied, see Prism Constant Correction, page 202. For some instruments, the Trimble Survey Controller software checks to see if a prism constant has been applied by the instrument and the Trimble Survey Controller software. When you select Station setup, messages are displayed in the status line showing what has/has not been checked. If the Trimble Survey Controller software cannot check the setting on the conventional instrument, do one of the following: •

If there is a prism constant set on the instrument, make sure that the prism constant in the Trimble Survey Controller software is set to 0.000.

•

If there is a prism constant set in the Trimble Survey Controller software, make sure that the prism constant in the instrument is set to 0.000.

j

Use the Height field to specify a target height. This is the distance from the point you are measuring, to the center of the target. For no . target height, access this field and press

45 6

Trimble Survey Controller Reference Manual Volume 2

Page 489

Using Conventional Instruments

19

Laser Rangefinder Select Laser Rangefinder to set the parameters for using a laser rangefinder with a conventional instrument. For more information about configuring a laser, see Chapter 20, Laser Observations. Topo point Select Topo point to set the parameters for observing topographic points. Use the Measure display field to define how the observations are displayed on the TSC1 data collector. Table 19.1 describes the display options. Table 19.1

Measure display options

Option

Corrections applied

Description

HA VA SD (raw)

None

Observation as seen on the conventional instrument display

HA VA SD

Prism constant

Raw observation corrected for prism constant

HA HD VD

Prism constant Pressure and temperature Instrument height and Target height Curvature and refraction

HA and HD from Station ground point to Target ground point and the height difference (VD) between these points

Az VA SD

Prism constant Pressure and temperature Orientation Curvature and refraction

Raw observation corrected for prism constant, orientation, and atmospheric effects.

Trimble Survey Controller Reference Manual Volume 2

457

Page 490

19

Using Conventional Instruments

Table 19.1

Measure display options (Continued)

Option

Corrections applied

Description

Az HD VD

Prism constant Pressure and temperature Orientation Instrument height and Target height Curvature and refraction

Same as HA HD VD but with backsight orientation applied to the HA

∆ Grid

Prism constant Pressure and temperature Orientation Instrument height and Target height Curvature and refraction Polar to rectangular

Trigonomical calculation of the ∆ NEE relative to the instrument

Prism constant Pressure and temperature Orientation Instrument height and Target height Curvature and refraction Polar to rectangular conversion Full coordinate transformation

Reduced grid coordinates

Grid

The same information as AZ HD VD but presented as rectangular coordinates

Use the Auto point step size field to set the increment size for automatic point numbering. The default is 1, although you can use larger step sizes as well as negative steps. Set the View before storage field to Yes to view observations before they are stored. Corrections Select Corrections to set the corrections associated with conventional observations.

C

45 8

Warning – Check the conventional instrument to make sure that corrections are not being applied by both the instrument and the Trimble Survey Controller software.

Trimble Survey Controller Reference Manual Volume 2

Page 491

Using Conventional Instruments

19

Use the PPM field to specify a PPM (parts per million) correction. This correction applies a scale factor to the electronic distance measurement based on environmental conditions. Manually key in the PPM correction, or enter the pressure and temperature of the surrounding environment and let the Trimble Survey Controller software compute it. Use the Curvature and refraction field to specify the index of refraction value. This is used to compute the curvature and refraction correction that is applied to vertical angle observations. Table 19.2 describes the options. Table 19.2

Curvature and refraction options

Option

Description

0.142 for use during the day

0.2 for use at night

None no correction applied

For some instruments, the Trimble Survey Controller software automatically checks to see if various corrections (PPM, prism constant, and curvature and refraction) are being applied correctly. If it finds that the corrections are being applied twice, a warning message appears. For details of the formulas and calculations used, see Conventional Instrument Calculations, page 200. Stakeout To set the as-staked point details: 1.

Set the View deltas before storage field to Yes. This lets you view the difference between a design point and the measured as-staked point before storing the point.

2.

Enter a value in the Horizontal tolerance field.

Trimble Survey Controller Reference Manual Volume 2

459

Page 492

19

Using Conventional Instruments

The Trimble Survey Controller software displays the deltas if this tolerance is exceeded. The default is 0.000 (deltas always displayed). 3.

Set the name of the as-staked point to be the next auto point name or a point name that is equivalent to its design name.

4.

Set the code of the as-staked point to be the design point name or the design point code.

5.

To display the as-staked deltas as grid (Northing, Easting, Elevation) values, choose Yes in the Display grid deltas field.

The stakeout graphical display screen displays directions using the conventional instrument as a reference point. To set the display: 1.

Choose a setting in the Deltas field. The options are: –

Angle and distance – navigate to a point using angle and distance

–

Distances – navigate to a point using distances only

For a comparison of these options see Figure 19.27 on Graphical display screen – distance measurement made, page 506. 2.

Use the Distance tolerance field to specify the allowable error in distance. If the target is within this distance from the point, the graphical stakeout display indicates that the distance(s) is correct.

3.

Use the Angle tolerance field to specify the allowable error in angle. If the conventional instrument is turned away from the point by less than this angle, the graphical stakeout display indicates that the angle is correct.

46 0

Trimble Survey Controller Reference Manual Volume 2