Page 83

General Operation Table 3.7

3

Symbols used by the in-field calculator (Continued)

Symbol Alternate Function keys

[7 [8 [9

Example

Result

Calculating the slope =1000 distance between two points

1001

Slope distance between Point 1000 and Point 1001

Calculating the horizontal distance between two points

=1000

1001

Horizontal distance between Point 1000 and Point 1001

Calculating the vertical distance between two points

=1000

1001

Vertical distance between Point 1000 and Point 1001 Note: The triangle symbols only appear in the list for a distance field.

Note – When you enter equations using the in-field calculator, enter the ‘=’ symbol first. Using different units You can use values with different units in the Trimble Survey Controller software in-field calculator. For example, if the system units are US feet, it is possible to add a value in meters to a value in feet. The answer will be in the system units. For example, to add 20 m to 10 USft when the system units are US survey feet: 1.

Key in =20

2.

Do one of the following:

3.

–

Press

–

Press

Um

. Then select Meters (m) and press

.

Key in +10 and press

\

\

.

.

The value 75.617 USft is inserted in the field.

Trimble Survey Controller Reference Manual Volume 1

53

Page 84

3

General Operation

3.7

TSC1 Controller Settings To review the Trimble Survey Controller software settings at any time, select Configuration / Controller from the main menu. The Controller settings menu appears.

3.7.1

Time/Date The Time/date screen displays the time and date settings for the Trimble Survey Controller software. Use it to set the following: •

Timeout – after this fixed period of inactivity, the TSC1 data collector turns itself off.

•

The fixed interval after which the Trimble Survey Controller software automatically records the current time (set the Timestamp field to the required interval between records) in the current job.

•

Your offset from UTC – so that you can display local time. When the TSC1 is not connected to a GPS receiver, edit the Local time and Local time offset fields. When the TSC1 is connected to a receiver but no survey is running, you can only edit the Local time offset field. You can enter positive and negative values in the Local time offset field.

•

Formats in which time and date are displayed.

•

The GPS time display. Set this to Date/time if you want to display the GPS time (in the QC records for example) as a local date and time instead of GPS weeks and seconds. The values are always stored as GPS weeks and seconds - this setting only configures the display.

Every time the TSC1 data collector is connected to a GPS receiver, the UTC time is automatically updated.

54

Trimble Survey Controller Reference Manual Volume 1

Page 85

General Operation 3.7.2

3

Language The Language screen contains a list of the language files uploaded into the Trimble Survey Controller. From the list, select a language. If an online Help file in another language is present, the Trimble Survey Controller software automatically uses that file when you select the corresponding language in the Language screen. If not, the online Help is in English. For information about transferring files, see Chapter 9, Data Transfer.

3.7.3

Hardware The Hardware screen displays information about the Trimble Survey Controller hardware. See Figure 3.9.

Figure 3.9

Hardware screen

To turn the screen backlight on, set the Backlight enabled field to Yes. This field resets to No every time the TSC1 data collector is turned off. Set the Beeper volume field to Off, Low, or High. For the Trimble Survey Controller software to automatically adjust the screen contrast, set the Automatic contrast adjustment field to Yes.

Trimble Survey Controller Reference Manual Volume 1

55

Page 86

3

General Operation

To charge the internal battery off a low-voltage (less than 15 V) external power source, set the Low voltage charging enabled field to Yes. Then see Using a Low Voltage Power Supply, page 28. Table 3.8 shows the options in the Internal battery field. Table 3.8

Internal battery options

Option

Description

Internal battery (being used)

TSC1 data collector is using the internal battery

Internal battery (not being used)

TSC1 is using an external power source

Internal battery (charging)

TSC1 is using an external power source and being recharged from that source

The Memory free field appears if no PCMCIA (PC) card is inserted. It shows the free space in the main memory. If a PC card is inserted, the Main memory free space and the PC card free space fields appear. The Version and Build number fields provide information about the version of the software that is running.

o Ó

The Serial number field displays the serial number of the TSC1 data collector. to display the Installed application options screen. This Press screen shows what software options you can install in the TSC1, and shows if they are enabled. It also shows the software support expiry date. to put the Trimble Survey Controller software into Press Upgrade mode. For more information, see Upgrading the Trimble Survey Controller Software, page 32.

56

Trimble Survey Controller Reference Manual Volume 1

Page 87

General Operation

3.8

3

Reviewing the Database From the main menu select Files / Review current job. Records are stored in chronological order. When you first access the database, the last page is displayed first.

• p P

• second function keys

To move around the database, use one of the following: • and softkeys arrow keys

æ

[) [_ [* [( ,

,

, and

To search for a particular item: 1.

Press

, and select an option:

–

Current record type

–

Point by name - enter the point name to search for

–

Point by code - enter the code to search for

–

Point by class - enter the class to search for

; \ \ N v 2.

To start the search, press

–

–

;\ or

:

causes the Trimble Survey Controller software to search up the database from the current position. causes it to search downwards.

For more information about a record, highlight the record and press . The and softkeys show the next record and the previous record respectively. Press to return to the database listing.

=

Note – If point coordinates appear as ‘?’ see Coordinate View Setting, page 58. It is possible to edit certain records, for example Code and Antenna.

Trimble Survey Controller Reference Manual Volume 1

57

Page 88

3

General Operation

Note – When you change an antenna height record in the database, the coordinates of some offset points (those stored as coordinates) are not updated. Also, the change in antenna height does not affect any postprocessed points that will be processed using the Trimble Geomatics Office™, Trimble Survey Office™ or GPSurvey™ software. Verify the antenna height information when you transfer the data to the office computer. Do the same if you download postprocessed points directly from the receiver to the office software. You can store a note at any position in the database. To do this:

Ú

1.

Highlight a record.

2.

Press

3.

. The note is stored immediately Enter the note and press before the record you highlighted in step 1.

\

. The Note screen appears.

\

=

The Note screen remains open until you press . Alternatively, press when there is no text on the screen. For details of the road information that is stored in a job, see Chapter 18, Roading.

3.8.1

Coordinate View Setting The setting in the Coordinate view field (WGS-84, Local, Grid, or HA VA SD, for example) determines what values are visible in the point record. It is possible to change the coordinate view setting for the job or just when viewing a point. To change the coordinate view setting for the job see System Units, page 101.

58

Trimble Survey Controller Reference Manual Volume 1

Page 89

General Operation

3

To change the Coordinate view setting for a point that you want to view:

\ o

1.

When reviewing the database, highlight the point record and . press

2.

Press and set the Coordinate view field as required.

The options are listed in Table 6.2 on page 101. If the coordinate value for a point is ‘?’, the following situations may have occurred:

3.8.2

•

The point may be stored as a GPS point but with the Coordinate view field set to Local or Grid and a datum transformation and projection not defined. Change the Coordinate view setting to WGS-84, define a datum transformation and/or projection, or calibrate the job.

•

The point may be stored as a polar vector from a point which has been deleted. Undelete the point.

•

In a 2D survey, a projection may have been defined with the Default elevation at null. Set the default elevation to approximate the elevation of the site.

Deleting and Undeleting Points, Lines, or Curves To delete a point, line, or curve in the Trimble Survey Controller software database:

\

1.

From the main menu select Files / Review current job.

2.

Highlight the point/line/curve to be deleted and press

3.

Press d

.

.

For points, the Search class changes to Deleted (normal), Deleted (control), Deleted (staked), Deleted (backsight), or Deleted (check), depending on the original search classification. 4.

Press

\

.

Trimble Survey Controller Reference Manual Volume 1

59

Page 90

3

General Operation

The Trimble Survey Controller software records a note after the original point/line/curve record, showing the time it was deleted. Note – When you delete a point/line/curve, the point symbol changes. For a topo point, for example, the symbol replaces the symbol. Note – When you delete a Face 1 or Face 2 observation that contributes to a matched pair record, the matched pair record is also deleted. The same applies to mean turned angle records. To undelete a point, line, or curve in the Trimble Survey Controller software database: 1.

From the main menu select Files / Review current job.

2.

Highlight the point/line/curve to be undeleted and press

3.

Press u

\

.

.

Deleted points A deleted point, line, or curve is not used in calculations, but it is still in the database. Deleting points, lines, or curves does not make a job file smaller. When you download a file that contains deleted points, the deleted points are not transferred to the office software. If you download a file using Data Transfer, GPLoad™ or TRIMMAP™ software, however, the deleted points are recorded in the Data Collector (.dc) file. They have a classification of Deleted. Some points, such as continuous offset points and some intersection and offset points, are stored as vectors from a source point. If you delete a source point, any point stored as a vector from that point has null (?) coordinates when you review the database point record.

B 60

\

Tip – To see how a point is stored, select Files / Review current job. Then , and view the Stored as field. For more highlight the point, press information, see Table 15.2 on page 375.

Trimble Survey Controller Reference Manual Volume 1

Page 91

General Operation

3.9

3

Responding to Messages If the Trimble Survey Controller software cannot operate normally, it displays an error message or a warning at the top of the screen, or a flashing message in the status line. For a list of Trimble Survey Controller software messages, see Appendix G, Messages, at the back of Volume 2.

3.9.1

Warnings and Error Messages

= O = O

You can usually continue working after acknowledging a warning, but you have to correct an error before normal operations can be resumed:

3.9.2

•

To acknowledge a warning, press or

.

•

To continue after an error message, press correct the mistake.

or and

Status Line Messages A status line message is generally displayed when the Trimble Survey Controller software cannot start or continue with its present function for some reason. For example, a message appears if there is no radio link or if the battery is low. A status line message generally remains on the screen until you (or the Trimble Survey Controller software) resolve the situation.

Trimble Survey Controller Reference Manual Volume 1

61

Page 92

3

General Operation

3.10

Auto-Connecting to an Instrument As soon as you turn on the TSC1 data collector, it tries to auto-connect to any device that it could be connected to. It first tries to connect to the device specified in the last Survey Style used. If this is unsuccessful, it uses the information contained in all available Survey Styles to determine what instrument it may be connected to. Working through the list, it checks its top and bottom ports for each instrument specified in the Survey Styles. The more Survey Styles there are stored, the longer this auto-connect process takes. Note – If many Survey Styles are defined, the auto-connect process may fail. When you start a survey, however, the Trimble Survey Controller software will connect to the device specified in the Survey Style. When connection is achieved, the appropriate icon appears in the status line. Table 3.3 on page 42 lists the icons that can appear. Note – If the TSC1 data collector is plugged into a GPS Total Station 4800 or 4700 receiver, a 4600LS receiver, or a Trimble conventional instrument and then turned on, the Trimble Survey Controller software automatically turns on that receiver or instrument.

62

Trimble Survey Controller Reference Manual Volume 1