Page 73
General Operation Table 3.3 Icon
3
Status line icons (Continued) What it shows A Trimble Site Surveyor™ 4400 receiver is in use
A Trimble 4600LS™ receiver is in use
1.800
1.800
A GPS Total Station 4800 receiver is in use, and the antenna height is 1.800 (the units are the system height units) An external antenna is in use, and the antenna height is 1.800 (the units are the system height units) A conventional instrument is in use
A conventional instrument is being used to measure a point
The height of a conventional target is 2.000 (the units are the system height units) 2.000
A conventional instrument station setup has been completed and the instrument height is 1.725 (the units are the system height units) 1.725
A static point is being measured
Radio signals are being received
Cellular modem signals are being received
Trimble Survey Controller Reference Manual Volume 1
43
Page 74
3
General Operation
Table 3.3
Status line icons (Continued)
Icon
What it shows WAAS signals are being received
Continuous points are being measured
If no survey is running: the number of satellites being tracked
5
If a survey is running: the number of satellites in the solution
(number varies)
The information provided by the satellite icon, the last icon in Table 3.3, depends on the type of survey you are doing and the receiver type:
Table 3.4
•
If using a single-frequency receiver see Table 3.4.
•
If using a dual-frequency receiver see Table 3.5.
Single-frequency satellite icon information
Survey type
What icon shows
No survey
Number of satellites tracked on L1
Uninitialized RTK
Number of common satellites on L1
Initialized RTK Uninitialized postprocessed kinematic or FastStatic
Number of satellites tracked on L1 for more than one epoch
Initialized postprocessed kinematic Real-time differential
Number of common satellites on L1
Postprocessed differential
Number of satellites tracked on L1 for more than one epoch
44
Trimble Survey Controller Reference Manual Volume 1
Page 75
General Operation Table 3.5
3
Dual-frequency satellite icon information
Survey type
What icon shows
No survey
Number of satellites tracked on L1
Uninitialized RTK
Number of common satellites on L2
Initialized RTK
Number of common satellites on L1
Uninitialized postprocessed kinematic or FastStatic
Number of satellites tracked on L2 for more than one epoch
Initialized postprocessed kinematic
Number of satellites tracked on L1 for more than one epoch
Real-time differential
Number of common satellites on L1
Postprocessed differential
Number of satellites tracked on L1 for more than one epoch
For more information about the satellites tracked by the receiver, see Satellites, page 348. When the TSC1 data collector is connected to a receiver, the status line displays the current survey mode. Table 3.6 explains these modes. Table 3.6
GPS status line mode display
Survey mode
Explanation
No Survey
Receiver is connected but a survey has not been started
RTK=Fixed
Current RTK survey is initialized and the solution type is L1 fixed (centimeter-level)
RTK=Float
Current RTK survey is not initialized and the solution type is L1 float
RTK=Check
Current RTK survey is verifying the initialization
RTK=Auto
Radio link is down in the current RTK survey and the solution is an autonomous position
RTK=WAAS
Radio link is down in the current RTK survey and the solution is a WAAS position
FastStatic
Current survey type is FastStatic
Trimble Survey Controller Reference Manual Volume 1
45
Page 76
3
General Operation
Table 3.6
GPS status line mode display (Continued)
Survey mode
Explanation
PPK=Fixed
Current postprocessed kinematic survey is initialized and, when postprocessed, should yield an L1 fixed or an iono-free (centimeter-level) solution
PPK=Float
Current postprocessed kinematic survey is not initialized and, when postprocessed, should yield an L1 float solution
PP differential
Current survey type is postprocessed differential
RT differential
Current survey type is real-time differential
Infill=Fixed
Current kinematic infill survey is initialized and, when postprocessed, should yield an L1 fixed or an iono-free (centimeter-level) solution
Infill=Float
Current kinematic infill survey is not initialized and, when postprocessed, should yield an L1 float solution
Infill
Current survey type is differential and you are doing an infill session
WAAS
Current survey type is differential and using signals from WAAS satellites
The Horizontal Angle (HA) and Vertical Angle (VA) appear in the status line when you use conventional instruments. The Root Mean Square (RMS) indicator is displayed when you are in Fine mode in a real-time kinematic survey. It shows the RMS of the current position, expressed in millicycles.
3.4
Menus Menus list the Trimble Survey Controller software functions. When you turn on the TSC1 data collector, the main menu appears after the Trimble logo screen. To return to the main menu at any time, press the key.
M
\
To select a menu item, highlight the required option using the arrow . Other menus, such as keys or by typing the first letter, and press the Files menu or the Instrument menu, appear when you select these items from the main menu. Figure 3.8 shows a two-page summary of the menu structure. 46
Trimble Survey Controller Reference Manual Volume 1
Page 77
General Operation
3
Files Job management Review current job Map of current job Status of current job Copy data between jobs Import / Export File manager
Trimble PC communications Send ASCII data Receive ASCII data
Key in Points Lines Curves Boundary Roads Templates Notes Survey – Items depend on the type of survey you are doing Start base receiver Station setup Start survey Start/Stop PP infill Measure points Measure rounds Continuous topo Offsets Measure laser points Stakeout Initialization Site calibration Swap base receiver End survey Figure 3.8
Points Lines Curves DTMs Roads
Trimble Survey Controller software menu structure This figure continues on page 48. Trimble Survey Controller Reference Manual Volume 1
47
Page 78
3
General Operation
Configuration Coordinate system Units Cogo settings
Job Controller Feature & attribute libraries Survey Styles
Time/date Language Hardware Cogo Inverse Intersections Traverse Subdivide a line Subdivide a curve Compute area Compute azimuth Compute distance
Items depend on the Survey Style selected
Instrument Items depend on the type of instrument the TSC1 is connected to Satellites Position Copy receiver files Receiver status Options Remote controller Navigate to point Station setup details Target Instrument controls
48
Trimble Survey Controller Reference Manual Volume 1
Rover options Topo point Rover radio Base options Base radio
Laser rangefinder FastStatic point Observed control point Rapid point Continuous points Stakeout Target Site calibration PP initialization times Duplicate point actions Instrument Corrections Traverse options
Page 79
General Operation
3.5
3
Data Fields Fields generally require you to input data. Field titles are on the left side of the screen display. Select options from a list or use the keypad to type in details. If a field has a list of options, this is indicated by a symbol to the left of the field. Press the key to display the list, or the key to cycle through the list.
* 3.6
(
(
Entering Data When a field is highlighted, press the do one of the following:
( key to access the field. Then
•
Type the numeric or alphanumeric details, depending on the field.
•
Select an item from a list of options. To do this, highlight the . required option and press
•
Select an item from a list of relevant records in the database. to see the list of available records, then place a Press check mark beside the required item(s) and press . (The softkey only appears when you edit certain fields.)
l l
\
\
0
\
• to see the list of available To enter a symbol, press symbols. Highlight the required symbol and press to insert it in the field. For a list of symbols see Table B.3 on page 185.
•
To enter a value in different units, type in the value and press . Select the units to be used and press . The value is converted to the system units and the result is inserted in the field. For more information, see Using different units, page 53.
U
\
When the field is complete, press move to the next field.
\ )
or to save any changes and
Trimble Survey Controller Reference Manual Volume 1
49
Page 80
3
General Operation
\
Press to accept the screen when all fields are complete. Some screens cannot be accepted unless certain fields have been completed. For example, in the Survey/Measure points screen, you cannot measure a point unless the Point name and Antenna height fields have values in them. If you press before completing these fields, a warning message appears.
\
3.6.1
Editing Details in a Field
[ (*
(
When a field is highlighted, press to access the beginning of the field. Press to access the end of the field. If already in the field, press to go to the beginning of it, to go to the end.
[S
[*
[B
Use the left and right arrow keys to move around inside the field. To . To delete a character press . insert a character press Note – Sometimes a field cannot be changed. When you try to access it, the highlight remains on the field title. For example, when you select Files / Current job status, it is not possible to change the fields in the screen that appears.
3.6.2
Using Quadrant Bearings To enter quadrant bearings: 1.
Make sure the system units are Quadrant bearings. For more information, see System Units, page 101.
2.
Enter the bearing in any Bearing field.
3.
Press
367 8 ,
,
, or
.
The quadrant bearing is inserted in the field. Example To enter the quadrant bearing N25° 30' 30"E in a bearing field:
50
3
•
Key in 25.3030.
•
Press
.
Trimble Survey Controller Reference Manual Volume 1
Page 81
General Operation 3.6.3
3
Using the In-Field Calculator Use the Trimble Survey Controller software’s in-field calculator to calculate values in the following fields: •
Northing
•
Easting
•
Elevation
•
Antenna height
•
Azimuth
•
Dist
•
H.Dist
•
Ë
V.Dist softkey appears when you access a field, the in-field If the calculator is available. In the Cogo / Intersections screen, for example, use it to sum two distances or to calculate the distance between two points in a H.Dist field.
B l
Tip – When calculating a distance between two points, press to select the points from the Trimble Survey Controller software database.
l
Note – When keying in a point name that includes spaces, put double quotes around it. To save time, use the softkey to select the point.
\
The Trimble Survey Controller software checks the syntax of the . If it is incorrect, the Trimble Survey formula when you press Controller software warns you and you can edit the formula. Note – When you enter an equation with two or more operators, use parentheses.
Trimble Survey Controller Reference Manual Volume 1
51
Page 82
3
General Operation
When you enter addition and subtraction equations in angle-, azimuth-, or quadrant-bearing fields, use consistent units for all values. Do not give units to some values but not others. For example, with the system units set to Quadrant bearings, to add N40°20'20"E and the angle 10°15'15", key in: =N40°20'20"E+10°15'15" or (even quicker): =N40°20'20"E+N10.1515
For information about using different units, see Using different units, page 53. Table 3.7 shows operators for the in-field calculator. Table 3.7
Symbols used by the in-field calculator
Symbol Alternate Function keys = + * / ( )
52
[q [a [b [c [d [h [i [6
Example
Result
Starting an equation
=3+4
7
Adding
=3+2+5
10
Subtracting
=5-3
2
Multiplying
=2*4
8
Dividing
=10/2
5
Inserting parentheses =2*(5+3)
Calculating the azimuth between two points
=1000
16
1001
Trimble Survey Controller Reference Manual Volume 1
Azimuth between Point 1000 and Point 1001 Note: The arrow symbol only appears in the list for an azimuth field.