Page 431
External Sensors
B J.2.3
J
Z\
Tip – After configuring an external sensor interface, it is recommended that you always test this interface. Select the external sensor from the list key. A check mark appears beside the sensor name. by pressing the Press to test this interface.
Using the Criterion to Record Heights You can use the configured external sensor interface together with a Criterion 300 to record heights as attributes, by following this procedure: 1.
Create a new rover data file. When the Asset Surveyor software opens this file, it automatically activates the pre-configured external sensor interface (as the Auto-connect field was set to ‘Yes’ in the previous section). The Asset Surveyor software can now communicate with the Criterion 300 rangefinder and you can begin to record heights.
2.
Start a feature. One of your feature’s attributes has the name Height, and it is this attribute which is used to store heights recorded by the Criterion 300.
3.
Enter attribute values for the feature while the Asset Surveyor software logs GPS positions. It is usually easiest to manually enter attributes before taking a recording with an external sensor. By following a set procedure like this you are less likely to forget to record or enter a particular piece of information.
4.
Follow the procedure described in the Criterion 300/400 Operator’s Guide for recording a height with the Criterion 300.
TSC1 Asset Surveyor Operation Manual
409
Page 432
J
External Sensors
The procedure essentially involves taking a distance measurement to the object in question, then taking an angle measurement to the base and top of the object. 5.
Press the ENTER button on the Criterion’s keypad to send the height to your TSC1 datalogger. Provided you have configured your external sensor interface correctly, and have connected and operated the Criterion 300 correctly, a value like 15.4 appears as the Height attribute for your feature.
6.
Press
\ to save the feature.
From this point on, the Asset Surveyor software treats the Height attribute as if it had been entered manually. It has no special properties.
J.2.4
Switching between Recording Laser Offsets and Heights You can use a Criterion laser rangefinder both for measuring offsets and for measuring the heights of objects. However, in order for the Asset Surveyor software to process these different types of data, you must indicate whether the Criterion is being used as an offset sensor or as a height sensor. You do this by alternately activating and deactivating the Height sensor and Laser entries in the Select sensor menu (accessible under the softkey when collecting data).
B
41 0
X
Tip – Do not configure both the Height sensor and the Laser to auto-connect; if you do this, only the Height sensor is activated and an error message appears when the Asset Surveyor software attempts to automatically activate the Laser interface.
TSC1 Asset Surveyor Operation Manual
Page 433
External Sensors
J.3
J
Digital Cameras Certain digital cameras can be controlled through an RS232 port. A message can be sent to the camera to trigger the taking of a photograph, and the camera may respond with a message that can be used subsequently to identify the photographic image that was recorded by the camera. A hypothetical camera communicates at 9600 baud with 8 data bits, 1 stop bit and odd parity. It is triggered either by pressing a button on the camera itself or by sending the ASCII character ‘*’ to the camera. When the camera is mounted on a vehicle it is typically easier to trigger the camera with an RS232 message. Each time the camera takes a photograph (whether triggered manually or with an RS232 message), it stores the digital image to its internal memory and emits the following message to its RS232 port: $PIC,nn CR LF where nn indicates the number of the stored image (1 to 64).
TSC1 Asset Surveyor Operation Manual
411
Page 434
J
External Sensors r
You can configure an Asset Surveyor external sensor to trigger the taking of a photograph whenever you press the softkey, and to store the number of the digital image as an attribute called Photo as follows:
41 2
1.
From the Asset Surveyor Configuration menu, select External sensors:
2.
Select Sensor 1 from this menu by highlighting Sensor 1 and . The configuration form for external sensor pressing number 1 appears:
S
TSC1 Asset Surveyor Operation Manual barcode.bmp
Page 435
External Sensors
3.
J
Change the fields in this form as shown below:
TSC1 Asset Surveyor Operation Manual
413
Page 436
J
External Sensors m
4.
Press to display the configuration form for serial communications (RS232) parameters, and enter the following values:
5.
to save the communications settings, then press Press to save the sensor configuration details.
\
\
The Asset Surveyor software returns you to the Select sensor configuration menu, and renames the first entry to the name that you specified for the sensor:
41 4
TSC1 Asset Surveyor Operation Manual
Page 437
External Sensors
J.4
J
Echo Sounders Echo-sounders are widely used to measure the depth of a body of water at a particular point, together with such phenomena as the level of sedimentation and the biomass (quantity of marine life). Most echo sounders emit measurements as they are taken (typically one or more per second). The most common mapping application for an echo sounder is to map the seabed, and in this case you configure the Asset Surveyor software to log each message from the echo sounder as an UNINTERPRETED_SENSOR_DATA record (which is not associated with a feature). A hypothetical echo sounder might measure the sea’s depth and transmit this information once per second at 4800 baud, with 8 data bits, 2 stop bits and no parity. Each measurement is emitted as a message with the following format: XXXX.X where XXXX.X is the depth of the sea at the point the measurement was taken. There are no delimiting characters that identify the start or end of each message, so the Asset Surveyor software must rely on timing information and the maximum length of 6 characters to isolate each message.
TSC1 Asset Surveyor Operation Manual
415
Page 438
J
External Sensors
You can configure an Asset Surveyor external sensor interface to log a depth message from this hypothetical echo sounder every 5 seconds as follows:
41 6
1.
From the Asset Surveyor Configuration menu, select External sensors:
2.
Select Sensor 1 from this menu by highlighting Sensor 1 and . The configuration form for external sensor pressing number 1 appears:
S
TSC1 Asset Surveyor Operation Manual
Page 439
External Sensors
3.
J
Change the fields in this form as shown below:
Note – By configuring the Asset Surveyor software to log a measurement every 5 seconds, it is able to discard any intervening messages and is more likely to be able to keep pace with the echo sounder.
B
Tip – When logging sensor data for mapping as independent UNINTERPRETED_SENSOR_DATA records, it is often convenient to configure the sensor interface to display a status line. This assures you that data is being logged continuously from the sensor.
TSC1 Asset Surveyor Operation Manual
417
Page 440
J
External Sensors
B
41 8
Tip – You can maximize the TSC1 datalogger’s ability to process external sensor data by disabling the optional Audible click and the Status line, and by minimizing the amount of additional GPS information which is logged at the same time.
m
4.
Press to display the configuration form for serial communications (RS232) parameters, and enter the following values:
5.
to save the communications settings, then press Press to save the sensor configuration details.
\
TSC1 Asset Surveyor Operation Manual
\