Page 411
Laser Rangefinders
I
Powering The Contour XLR rangefinder is powered by an internal 9.6 V NiMH battery. Environmental limitations The Contour XLR rangefinder can be used at temperatures ranging between –10°C and +45°C (+14°F to +113°F).
I.7.2
Accessories The Contour XLR laser rangefinder can be used in four ways:
I.7.3
•
As a handheld instrument.
•
With a survey pole.
•
With the optional monopod. The monopod includes an encoder module for high accuracy horizontal angle readings, a slot for a datalogger bracket, and a screw thread at the top of the monopod pole for attaching a GPS receiver or antenna.
•
With the optional tripod. The laser rangefinder can be mounted on the tripod, using either a bracket or the MDL encoder module.
Cabling for Use with the Asset Surveyor Software The Contour XLR laser rangefinder can be purchased with an optional download cable. This cable provides a 9-pin connector which can be plugged directly into the ESP port of a Pro XL. For use with the GPS Pathfinder Pro XR or Pro XRS, a second data cable (P/N 32287) is required as an adaptor to connect to the optional 9-pin adaptor.
TSC1 Asset Surveyor Operation Manual
389
Page 412
I
Laser Rangefinders
Cabling for the Pro XRS receiver If you have a Pro XRS GPS receiver, connect the Contour XLR laser rangefinder to your receiver and datalogger as shown in Figure I.16.
Figure I.16
39 0
Contour XLR laser rangefinder cabling diagram for Pro XRS with TSC1
TSC1 Asset Surveyor Operation Manual
Page 413
Laser Rangefinders
I
Cabling for the Pro XR receiver If you have a Pro XR GPS receiver, connect the Contour XLR laser rangefinder to your receiver and datalogger as shown in Figure I.17.
Figure I.17
Contour XLR laser rangefinder cabling diagram for Pro XR with TSC1
TSC1 Asset Surveyor Operation Manual
391
Page 414
I
Laser Rangefinders
Cabling for the Pro XL receiver If you have a Pro XL GPS receiver, connect the Contour XLR laser rangefinder to your receiver and datalogger as shown in Figure I.18.
Figure I.18
39 2
Contour XLR laser rangefinder cabling diagram for Pro XL with TSC1
TSC1 Asset Surveyor Operation Manual
Page 415
Laser Rangefinders I.7.4
I
Configuration for Use with the Asset Surveyor Software This section provides instructions for configuring the Contour XLR laser rangefinder itself. For more information on configuring the Asset Surveyor software to work with the Contour XLR laser rangefinder, see Using the Contour XLR with the Asset Surveyor Software, page 394. Calibration of the Contour XLR Whenever you use the Contour XLR after storing it for a period, or in a new environment, calibrate the Contour XLR’s compass. This is particularly important if you feel that the site in which you are working is hostile in the sense of there being local magnetic field distortions (for example, a vehicle, pipeline, or overhead or underground power cable). The purpose of calibration is to distribute compass error smoothly through a 360° circle. Note – The calibration procedure does not modify the compass’s idea of where magnetic north is. It simply distributes local distortion of the earth’s magnetic field evenly through a 360° circle. This is important as it ensures that compass readings are locally consistent. If you want to account for an error in the compass’s determination of magnetic north, do this by entering a new value for the Magnetic declination field in the Asset Surveyor software’s Units and display configuration form. Calibration of the compass is quick and simple. Follow the instructions below: 1.
Turn on the Contour XLR.
2.
Press the Menu key.
3.
Press the Down arrow key until the entry Comp appears in brackets, and then press Enter.
4.
Press the Down key until CAL is selected, and then press Enter. The display shows the message Initializing – please wait.
TSC1 Asset Surveyor Operation Manual
393
Page 416
I
Laser Rangefinders
5.
When the display shows the message Rotate unit for calibration, pull and hold the trigger.
6.
Slowly rotate through 360° twice, taking 1–2 minutes per revolution. While turning, slowly pitch and roll the unit up and down and side to side. As the Contour XLR is rotated, the data point count on the display increases. When the count reaches 275, calibration is complete.
7.
Release the trigger. The Contour XLR returns to the previous operating mode.
I.7.5
Using the Contour XLR with the Asset Surveyor Software As mentioned previously, the practical accuracy of the fluxgate compass in typical field use is around ±0.5°. This yields a steady reduction in accuracy as the distance between the laser and a target point increases. At a distance of 100–200 m, the average positional error when using the Contour XLR is approximately 1 m (in addition to the error of your GPS measurement).
39 4
TSC1 Asset Surveyor Operation Manual
Page 417
Laser Rangefinders
I
Testing When you first connect the Contour XLR to your Trimble GPS system, test that it is correctly configured and that all components are working correctly. Select the Configuration entry from the Asset Surveyor software’s Main menu:
Select External sensors from the Configuration menu. The menu of available sensors appears:
TSC1 Asset Surveyor Operation Manual
395
Page 418
I
Laser Rangefinders
S
Configuring the Asset Surveyor software Configure the special Laser sensor to work with the LaserCraft softkey. The Laser Contour XLR. To do this, press the range-finder configuration form appears:
Set the Type field to ‘Contour XLR’. If you generally use the Contour XLR rangefinder when collecting data, and if you typically do not use any other type of external sensor, then set the Auto-connect field to ‘Yes’. Set the Confirm offsets field to ‘On’ to display the Offset form for the currently open feature whenever you send an offset from a laser rangefinder. Set the Confirm offsets field to ‘Off’ to automatically record offset values to the open feature when you fire the rangefinder. The Offset form does not appear unless an entry is required. The message Offset received appears briefly in the status line, but no other notification appears unless an entry is required. You can press in the attribute entry form to open the Offset form if you want to confirm offset values.
O
Set the Serial port according to the port you connect the LaserCraft Contour XLR to, either ‘Top’ or ‘Bottom’. Press
39 6
\ to save these settings and return to the Select sensor menu.
TSC1 Asset Surveyor Operation Manual
Page 419
Laser Rangefinders
I
Activating the laser interface You can specify that you want the Asset Surveyor software to accept input from the laser rangefinder, by selecting the Laser entry from the Select sensor menu. When you do this, a check mark appears beside the Laser entry to indicate that the rangefinder interface has been activated:
Z
Once the rangefinder interface has been activated (and provided the softkey appears. Laser entry in the menu is highlighted), the Once the rangefinder interface has been activated, the Asset Surveyor software accepts communications from it. You can configure the Asset Surveyor software to automatically activate the laser rangefinder interface when you start data collection by setting the Auto-connect field to ‘Yes’, as described above.
TSC1 Asset Surveyor Operation Manual
397
Page 420
I
Laser Rangefinders
If you attempt to activate the laser rangefinder interface and the serial port is already in use by another sensor, the Asset Surveyor software displays a message similar to the following:
The Asset Surveyor software does not activate the rangefinder interface.
Z
Checking the laser interface When the laser rangefinder is active (and highlighted in the list of to open a status form for the rangefinder: external sensors), press
39 8
TSC1 Asset Surveyor Operation Manual